Metrosep C 4 - 100/2.0
6.1050.210
Metrosep C 4 - 100/2.0
en
6.1050.210
Visão geral
The short version of the Metrosep C 4 "Microbore" cation separation column with a 2 mm inner diameter is intended for rapid determinations of the standard cations. Very short retention times are achieved; however the elution times of sodium and ammonium still differ by 25 s. When a special eluent is used, the six cations lithium, ammonium, sodium, calcium, magnesium and potassium can be determined in less than 5 minutes with the Metrosep C 4 - 100/2.0. With its low eluent flow, this column is particularly suitable for IC-MS coupling.
Especificações técnicas
| Housing material | PEEK |
|---|---|
| Carrier material | Silica gel with carboxyl groups |
| Particle size | 5 µm |
| Standard flow | 0.2 mL/min |
| Maximum pressure | 25 MPa |
| Maximum flow | 1.6 mL/min |
| pH range | 2–7 |
| Column dimensions | 100 x 2.0 mm |
| Temperature range | 20–60 °C |
Cromatograma
-
- Threaded stopper
- 6.2744.060
- For UNF 10/32. Stopper for IC, e.g. for the sealing of columns.
- <p>For UNF 10/32. Stopper for IC, e.g. for the sealing of columns.</p>
- PCS
- 2
-
- Threaded stopper
- 6.2744.060
- For UNF 10/32. Stopper for IC, e.g. for the sealing of columns.
- <p>For UNF 10/32. Stopper for IC, e.g. for the sealing of columns.</p>
- PCS
- 2
-
- Metrosep C 4 Guard/2.0
- 6.1050.600
- The Metrosep C 4 Guard/2.0 contains the C-4 column material and is used to protect all Metrosep cation columns with 2 mm inner diameters which have a substrate based on silica gel. Particles and contamination are reliably retained, considerably prolonging the service life of the analytical separation column. The economical price is an additional plus. The Metrosep C 4 Guard/2.0 also works based on the "On Column Guard System" and is screwed directly onto the separation column with virtually no dead volume.
- <p>The Metrosep C 4 Guard/2.0 contains the C-4 column material and is used to protect all Metrosep cation columns with 2 mm inner diameters which have a substrate based on silica gel. Particles and contamination are reliably retained, considerably prolonging the service life of the analytical separation column. The economical price is an additional plus. The Metrosep C 4 Guard/2.0 also works based on the "On Column Guard System" and is screwed directly onto the separation column with virtually no dead volume.</p>
- PCS
- 1
- Metrosep C 4 S-Guard/2.0
- 6.1050.610
- The Metrosep C 4 Guard/2.0 contains the C-4 column material and is used to protect all Metrosep cation columns with 2 mm inner diameters which have a substrate based on silica gel. Particles and contamination are reliably retained, considerably prolonging the service life of the analytical separation column. The economical price is an additional plus.
- <p>The Metrosep C 4 Guard/2.0 contains the C-4 column material and is used to protect all Metrosep cation columns with 2 mm inner diameters which have a substrate based on silica gel. Particles and contamination are reliably retained, considerably prolonging the service life of the analytical separation column. The economical price is an additional plus.</p>
- PCS
- 1