Foi redireccionado para a sua versão local da página solicitada.
i-Raman NxG 1064

i-Raman NxG 1064

29540050

i-Raman NxG 1064

en

29540050

Visão geral

The i-Raman NxG 1064 is a high-performance Raman spectrometer purpose-built for the most challenging and complex sample types. Featuring a 1064 nm laser and a wide spectral range of 100–2500 cm⁻¹, it excels at dramatically reducing fluorescence interference, making it ideal for analysis of highly fluorescent, brightly colored, or natural products that are problematic for conventional Raman systems.

This advanced capability enables rapid, accurate measurements, even with challenging samples often found in pharmaceuticals, nutraceuticals, and petroleum sectors. Its versatile setup—including the ability to perform see-through measurements through opaque containers - delivers excellent results in rigorous quality control processes where suppressing fluorescence is essential.

The i-Raman NxG 1064 is the preferred choice for users who need reliable, fluorescence-free Raman analysis of challenging quality control samples.

Discover how this near-infrared laser helps you make the most challenging quality control measurements:

  • High-sensitivity spectrometers deliver results in seconds and can detect the weakest Raman signals.
  • Near-IR laser measures highly colored and dark samples with ease.
  • Flexible fiber optic probe compatible with a wide array of accessories including a vial holder, cuvette holder, immersion probe, and see-through adapter.
  • Powerful SpecSuite software for easy Raman data collection in addition to quantitative model building, identification with spectral libraries, and routine analysis.
  • Compact and stackable to save on valuable bench space.
     

    • Polystyrene Validation Cap
    • 607510040
    • Validation cap with integrated polystyrene standard for lab-grade Raman probes with shaft diameter of 9.5 mm.
    • <p>Validation cap with integrated polystyrene standard for lab-grade Raman probes with shaft diameter of 9.5 mm.</p>
    • PCS
    • 1
    • Laser key for i-Raman NxG
    • 607510050
    • Laser keys for i-Raman NxG and i-Raman Duo systems.
    • <p>Laser keys for i-Raman NxG and i-Raman Duo systems.</p>
    • PCS
    • 1
    • Interlock Plug for i-Raman NxG
    • 607510010
    • Interlock plug for i-Raman NxG and i-Raman Duo systems.
    • <p>Interlock plug for i-Raman NxG and i-Raman Duo systems.</p>
    • PCS
    • 1
    • AC Power Cord for i-Raman Series
    • 607510060
    • AC power cord for i-Raman NxG and i-Raman Duo systems.
    • <p>AC power cord for i-Raman NxG and i-Raman Duo systems.</p>
    • PCS
    • 1
    • High Throughput Lab-grade Raman Probe (1064 nm)
    • 607510260
    • High-throughput lab-grade fiber optic Raman probe assembly with trigger button. 1.5 meter fiber length.Compatible with i-Raman NxG 1064.
    • <p>High-throughput lab-grade fiber optic Raman probe assembly with trigger button. 1.5 meter fiber length.</p><p>Compatible with i-Raman NxG 1064.</p>
    • PCS
    • 1
    • USB-C to USB-C cable for i-Raman NxG
    • 607510030
    • USB-C to USB-C cable for i-Raman NxG and i-Raman Duo systems.
    • <p>USB-C to USB-C cable for i-Raman NxG and i-Raman Duo systems.</p>
    • PCS
    • 1
    • Polystyrene Validation Cap
    • 607510040
    • Validation cap with integrated polystyrene standard for lab-grade Raman probes with shaft diameter of 9.5 mm.
    • <p>Validation cap with integrated polystyrene standard for lab-grade Raman probes with shaft diameter of 9.5 mm.</p>
    • PCS
    • 1
    • Laser key for i-Raman NxG
    • 607510050
    • Laser keys for i-Raman NxG and i-Raman Duo systems.
    • <p>Laser keys for i-Raman NxG and i-Raman Duo systems.</p>
    • PCS
    • 1
    • Interlock Plug for i-Raman NxG
    • 607510010
    • Interlock plug for i-Raman NxG and i-Raman Duo systems.
    • <p>Interlock plug for i-Raman NxG and i-Raman Duo systems.</p>
    • PCS
    • 1
    • AC Power Cord for i-Raman Series
    • 607510060
    • AC power cord for i-Raman NxG and i-Raman Duo systems.
    • <p>AC power cord for i-Raman NxG and i-Raman Duo systems.</p>
    • PCS
    • 1
    • High Throughput Lab-grade Raman Probe (1064 nm)
    • 607510260
    • High-throughput lab-grade fiber optic Raman probe assembly with trigger button. 1.5 meter fiber length.Compatible with i-Raman NxG 1064.
    • <p>High-throughput lab-grade fiber optic Raman probe assembly with trigger button. 1.5 meter fiber length.</p><p>Compatible with i-Raman NxG 1064.</p>
    • PCS
    • 1
    • USB-C to USB-C cable for i-Raman NxG
    • 607510030
    • USB-C to USB-C cable for i-Raman NxG and i-Raman Duo systems.
    • <p>USB-C to USB-C cable for i-Raman NxG and i-Raman Duo systems.</p>
    • PCS
    • 1
    • SpecSuite Software License - Laboratory Software Quantification
    • 66079160
    • SpecSuite license for quantification. Includes quantitative model development module and routine analysis prediction.
    • <p>SpecSuite license for quantification. Includes quantitative model development module and routine analysis prediction.</p>
    • PCS
    • 1
    • SpecSuite Comprehensive Library
    • 66079180
    • SpecSuite Metrohm Comprehensive Raman Library - More than 27,700 spectral entries of chemicals, minerals, organic chemicals, solvents, polymers, dyes and pigments, TICs, TIMs, inorganics and organometallics, personal care products, and illicit materials.
    • <p>SpecSuite Metrohm Comprehensive Raman Library - More than 27,700 spectral entries of chemicals, minerals, organic chemicals, solvents, polymers, dyes and pigments, TICs, TIMs, inorganics and organometallics, personal care products, and illicit materials.</p>
    • PCS
    • 1
    • SpecSuite MCRL Organics Complete Library
    • 66079200
    • Metrohm Comprehensive Raman Library (MCRL) Organics for SpecSuite software.
    • <p>Metrohm Comprehensive Raman Library (MCRL) Organics for SpecSuite software.</p>
    • PCS
    • 1
    • SpecSuite MCRL Dyes, Pigments, and Stains Library
    • 66079230
    • Metrohm Comprehensive Raman Library (MCRL) Dyes, Pigments, and Stains for SpecSuite software.
    • <p>Metrohm Comprehensive Raman Library (MCRL) Dyes, Pigments, and Stains for SpecSuite software.</p>
    • PCS
    • 1
    • SpecSuite Minerals Library
    • 66079240
    • Metrohm Minerals library for SpecSuite software.
    • <p>Metrohm Minerals library for SpecSuite software.</p>
    • PCS
    • 1
    • SpecSuite Comprehensive USP Library
    • 66079250
    • Metrohm Comprehensive USP Raman Library for SpecSuite containing ~ 900 traceable certified items.
    • <p>Metrohm Comprehensive USP Raman Library for SpecSuite containing ~ 900 traceable certified items.</p>
    • PCS
    • 1
    • SpecSuite Illicit and General Chemicals Library
    • 66079260
    • Metrohm Illicit and General Chemicals Raman Library for SpecSuite software. Includes drugs, TICs, TIMs, precursors, and general chemicals.
    • <p>Metrohm Illicit and General Chemicals Raman Library for SpecSuite software. Includes drugs, TICs, TIMs, precursors, and general chemicals.</p>
    • PCS
    • 1
    • Vial Holder Accessory
    • 607510410
    • Vial holder accessory for use with lab-grade Raman probes with shaft diameter of 9.5 mm. Compatible with 15 mm-diameter vial. 6-pack of 15 mm borosilicate glass vials included.
    • <p>Vial holder accessory for use with lab-grade Raman probes with shaft diameter of 9.5 mm. Compatible with 15 mm-diameter vial. 6-pack of 15 mm borosilicate glass vials included.</p>
    • PCS
    • 1
    • Cuvette Holder Accessory
    • 607510420
    • Cuvette holder for use with lab-grade Raman probes with shaft diameter of 9.5 mm. Compatible with standard cuvettes of 12.5 mm x 12.5 mm outer diameter (1 cm path length) for sampling liquids or powders.
    • <p>Cuvette holder for use with lab-grade Raman probes with shaft diameter of 9.5 mm. Compatible with standard cuvettes of 12.5 mm x 12.5 mm outer diameter (1 cm path length) for sampling liquids or powders.</p>
    • PCS
    • 1
    • High Throughput Lab-grade Raman Probe (1064 nm), 5 m
    • 607510270
    • High-throughput lab-grade fiber optic Raman probe assembly with trigger button. 5 meter fiber length.Compatible with i-Raman NxG 1064.
    • <p>High-throughput lab-grade fiber optic Raman probe assembly with trigger button. 5 meter fiber length.</p><p>Compatible with i-Raman NxG 1064.</p>
    • PCS
    • 1
    • Stainless Steel Immersion Shaft for Lab-grade Raman Probe
    • 607511010
    • 316 Stainless steel immersion shaft compatible with lab-grade Raman probes. Includes adjustable shaft adapter. Compatible with 532, 785, 860 and 1064 nm wavelengths.
    • <p>316 Stainless steel immersion shaft compatible with lab-grade Raman probes. Includes adjustable shaft adapter. Compatible with 532, 785, 860 and 1064 nm wavelengths.</p>
    • PCS
    • 1
    • Hastelloy Immersion Shaft for Lab-grade Raman Probe
    • 607510240
    • C-276 Hastelloy immersion shaft compatible with lab-grade Raman probes. Includes adjustable shaft adapter. Compatible with 532, 785, 860 and 1064 nm wavelengths.
    • <p>C-276 Hastelloy immersion shaft compatible with lab-grade Raman probes. Includes adjustable shaft adapter. Compatible with 532, 785, 860 and 1064 nm wavelengths.</p>
    • PCS
    • 1
    • Standard Shaft for Lab-Grade Probe (1064 nm)
    • 607510340
    • Replacement shaft for 1064 nm excitation lab-grade Raman probe assembly. Working distance 5.9 mm.
    • <p>Replacement shaft for 1064 nm excitation lab-grade Raman probe assembly. Working distance 5.9 mm.</p>
    • PCS
    • 1
    • Distance Regulator Cap
    • 607510430
    • Distance regulator cap for standard lab-grade Raman probe shaft.
    • <p>Distance regulator cap for standard lab-grade Raman probe shaft.</p>
    • PCS
    • 1
    • See-Through Shaft (1064 nm)
    • 607510350
    • See-through shaft for use with lab-grade Raman probes. Optimized for 1064 nm laser.Contains focus adapter, surface regulator, and light shield.
    • <p>See-through shaft for use with lab-grade Raman probes. Optimized for 1064 nm laser.</p><p>Contains focus adapter, surface regulator, and light shield.</p>
    • PCS
    • 1
    • See-Through Raman probe (1064 nm)
    • 607510300
    • See-through probe for measurements through packaging. 1.5 meter fiber length. Accessories included: Focus adapter, surface regulator, calibration cap.Compatible with i-Raman NxG 1064.
    • <p>See-through probe for measurements through packaging. 1.5 meter fiber length. Accessories included: Focus adapter, surface regulator, calibration cap.</p><p>Compatible with i-Raman NxG 1064.</p>
    • PCS
    • 1
    • See-Through Raman Probe (1064 nm), 5 m
    • 607510310
    • See-through probe for measurements through packaging. 5 meter fiber length. Accessories included: Focus adapter, surface regulator, calibration cap.Compatible with i-Raman NxG 1064.
    • <p>See-through probe for measurements through packaging. 5 meter fiber length. Accessories included: Focus adapter, surface regulator, calibration cap.</p><p>Compatible with i-Raman NxG 1064.</p>
    • PCS
    • 1
    • SpecSuite CWA Library
    • 66079280
    • Chemical warfare agents (CWA) library for SpecSuite software.
    • <p>Chemical warfare agents (CWA) library for SpecSuite software.</p>
    • PCS
    • 1