    • Solvotrode easyClean (fixed cable 1.2 m)
    • 6.0229.010
    • Combined pH electrode with flexible easyClean diaphragm and fixed cable (1.2 m) for all non-aqueous acid/base titrations. The glass membrane is optimized for poorly conducting solutions, and thanks to the easy-to-clean easyClean diaphragm, the electrode is also well suited for heavily contaminated samples, such as used oil. This electrode can be used with non-aqueous reference electrolytes (lithium chloride or tetraethylammonium bromide). Storage in the respective reference electrolyte.The Solvotrode easyClean is also available under the article number 6.0229.020 with a fixed cable length of 2.0 m.
    • <p>Combined pH electrode with flexible easyClean diaphragm and fixed cable (1.2 m) for all non-aqueous acid/base titrations. <br/>The glass membrane is optimized for poorly conducting solutions, and thanks to the easy-to-clean easyClean diaphragm, the electrode is also well suited for heavily contaminated samples, such as used oil. <br/>This electrode can be used with non-aqueous reference electrolytes (lithium chloride or tetraethylammonium bromide). Storage in the respective reference electrolyte.</p><p>The Solvotrode easyClean is also available under the article number 6.0229.020 with a fixed cable length of 2.0 m.</p>
    • PCS
    • 1
    • Stirring propeller / 87 mm
    • 6.1909.010
    • Propeller stirrer, length from lower edge of SGJ: 96 mm. For use with beakers with 722, 802 Rod Stirrer
    • <p>Propeller stirrer, length from lower edge of SGJ: 96 mm. For use with beakers with 722, 802 Rod Stirrer</p>
    • PCS
    • 1
    • Support stand without support rod
    • 6.2001.060
    • To attach an 801, 804, 803 Stirrer to a Titrando, Titrino plus, Dosimat plus or 856 and 867.
    • To attach an 801, 804, 803 Stirrer to a Titrando, Titrino plus, Dosimat plus or 856 and 867.
    • PCS
    • 1
    • Clamping ring
    • 6.2013.010
    • For support rods with a diameter of 10 mm.
    • <p>For support rods with a diameter of 10 mm.</p>
    • PCS
    • 1
    • Electrode holder
    • 6.2021.020
    • Electrode holder for 4 electrodes and 2 buret tips
    • Electrode holder for 4 electrodes and 2 buret tips
    • PCS
    • 1
    • Numerical USB keypad
    • 6.2147.000
    • Numerical USB keypad for Titrino plus, Dosimat plus, 862 Compact Titrosampler, 869 Compact Sample Changer, 863 Compact Autosampler and 899 Coulometer. With two integrated USB connectors.
    • <p>Numerical USB keypad for Titrino plus, Dosimat plus, 862 Compact Titrosampler, 869 Compact Sample Changer, 863 Compact Autosampler and 899 Coulometer. With two integrated USB connectors. </p>
    • PCS
    • 1
    • TEABr 0.4 mol/L in ethylene glycol (250 mL)
    • 6.2320.000
    • Electrolyte solution TEABr (tetraethylammonium bromide in ethylene glycol), c(TEABr) = 0.4 mol/L
    • Electrolyte solution TEABr (tetraethylammonium bromide in ethylene glycol), c(TEABr) = 0.4 mol/L
    • PCS
    • 1
    • Protective cover for Titrino plus
    • 6.2723.310
    • Protective cover for display and keypad for all instruments of the Titrino plus family. Suitable for: 848 Titrino plus, 862 Compact Titrosampler, 863 Compact Autosampler, 865 Dosimat plus, 869 Compact Sample Changer, 870 KF Titrino plus, 876 Dosimat plus, 877 Titrino plus, 899 Coulometer. 
    • <p>Protective cover for display and keypad for all instruments of the Titrino plus family. </p> <p>Suitable for: 848 Titrino plus, 862 Compact Titrosampler, 863 Compact Autosampler, 865 Dosimat plus, 869 Compact Sample Changer, 870 KF Titrino plus, 876 Dosimat plus, 877 Titrino plus, 899 Coulometer.</p> <p> </p>
    • PCS
    • 1
    • Wrench
    • 6.2739.010
    • For exchange units.
    • For exchange units.
    • PCS
    • 1
    • Exchange Unit 20 mL
    • 6.3026.220
    • Exchange unit with integrated data chip with 20 mL glass cylinder and light protection. PCTFE/PTFE flat stopcock, FEP tubing connection, anti-diffusion buret tip and standard amber glass reagent bottle.
    • <p>Exchange unit with integrated data chip with 20 mL glass cylinder and light protection. PCTFE/PTFE flat stopcock, FEP tubing connection, anti-diffusion buret tip and standard amber glass reagent bottle.</p>
    • PCS
    • 1
    • Titrino plus methods USB Stick
    • 6.6061.010
    • Contains the FOOD PAC, WINE PAC and OIL PAC methods for direct import into the Titrino plus.
    • Contains the FOOD PAC, WINE PAC and OIL PAC methods for direct import into the Titrino plus.
    • PCS
    • 1
    • 802 Rod Stirrer for 727 Ti Stand
    • 1.802.0010
    • Rod stirrer with separate 6.2137.000 Speed controller and 6.1909.010 Propeller stirrer.
    • Rod stirrer with separate 6.2137.000 Speed controller and 6.1909.010 Propeller stirrer.
    • PCS
    • 1
    • 804 Ti Stand without stand rod
    • 1.804.0010
    • Titration stand and controller for 802 Stirrer. The 804 Ti Stand together with the optional 802 Stirrer provides an alternative to the magnetic stirrer. Without stand.
    • Titration stand and controller for 802 Stirrer. The 804 Ti Stand together with the optional 802 Stirrer provides an alternative to the magnetic stirrer. Without stand.
    • PCS
    • 1
    • 848 Titrino plus
    • 1.848.0010
    • Compact titrator fordynamic (DET) titrations with automatic equivalence point finding; monotonic (MET) titrations with automatic equivalence point finding; endpoint titrations (SET);  
    • <p>Compact titrator for</p><ul><li>dynamic (DET) titrations with automatic equivalence point finding</li><li>monotonic (MET) titrations with automatic equivalence point finding</li><li>endpoint titrations (SET)</li></ul><p> </p>
    • PCS
    • 1
    • Solvotrode easyClean (fixed cable 1.2 m)
    • 6.0229.010
    • Combined pH electrode with flexible easyClean diaphragm and fixed cable (1.2 m) for all non-aqueous acid/base titrations. The glass membrane is optimized for poorly conducting solutions, and thanks to the easy-to-clean easyClean diaphragm, the electrode is also well suited for heavily contaminated samples, such as used oil. This electrode can be used with non-aqueous reference electrolytes (lithium chloride or tetraethylammonium bromide). Storage in the respective reference electrolyte.The Solvotrode easyClean is also available under the article number 6.0229.020 with a fixed cable length of 2.0 m.
    • <p>Combined pH electrode with flexible easyClean diaphragm and fixed cable (1.2 m) for all non-aqueous acid/base titrations. <br/>The glass membrane is optimized for poorly conducting solutions, and thanks to the easy-to-clean easyClean diaphragm, the electrode is also well suited for heavily contaminated samples, such as used oil. <br/>This electrode can be used with non-aqueous reference electrolytes (lithium chloride or tetraethylammonium bromide). Storage in the respective reference electrolyte.</p><p>The Solvotrode easyClean is also available under the article number 6.0229.020 with a fixed cable length of 2.0 m.</p>
    • PCS
    • 1
    • Stirring propeller / 87 mm
    • 6.1909.010
    • Propeller stirrer, length from lower edge of SGJ: 96 mm. For use with beakers with 722, 802 Rod Stirrer
    • <p>Propeller stirrer, length from lower edge of SGJ: 96 mm. For use with beakers with 722, 802 Rod Stirrer</p>
    • PCS
    • 1
    • Support stand without support rod
    • 6.2001.060
    • To attach an 801, 804, 803 Stirrer to a Titrando, Titrino plus, Dosimat plus or 856 and 867.
    • To attach an 801, 804, 803 Stirrer to a Titrando, Titrino plus, Dosimat plus or 856 and 867.
    • PCS
    • 1
    • Clamping ring
    • 6.2013.010
    • For support rods with a diameter of 10 mm.
    • <p>For support rods with a diameter of 10 mm.</p>
    • PCS
    • 1
    • Electrode holder
    • 6.2021.020
    • Electrode holder for 4 electrodes and 2 buret tips
    • Electrode holder for 4 electrodes and 2 buret tips
    • PCS
    • 1
    • Numerical USB keypad
    • 6.2147.000
    • Numerical USB keypad for Titrino plus, Dosimat plus, 862 Compact Titrosampler, 869 Compact Sample Changer, 863 Compact Autosampler and 899 Coulometer. With two integrated USB connectors.
    • <p>Numerical USB keypad for Titrino plus, Dosimat plus, 862 Compact Titrosampler, 869 Compact Sample Changer, 863 Compact Autosampler and 899 Coulometer. With two integrated USB connectors. </p>
    • PCS
    • 1
    • TEABr 0.4 mol/L in ethylene glycol (250 mL)
    • 6.2320.000
    • Electrolyte solution TEABr (tetraethylammonium bromide in ethylene glycol), c(TEABr) = 0.4 mol/L
    • Electrolyte solution TEABr (tetraethylammonium bromide in ethylene glycol), c(TEABr) = 0.4 mol/L
    • PCS
    • 1
    • Protective cover for Titrino plus
    • 6.2723.310
    • Protective cover for display and keypad for all instruments of the Titrino plus family. Suitable for: 848 Titrino plus, 862 Compact Titrosampler, 863 Compact Autosampler, 865 Dosimat plus, 869 Compact Sample Changer, 870 KF Titrino plus, 876 Dosimat plus, 877 Titrino plus, 899 Coulometer. 
    • <p>Protective cover for display and keypad for all instruments of the Titrino plus family. </p> <p>Suitable for: 848 Titrino plus, 862 Compact Titrosampler, 863 Compact Autosampler, 865 Dosimat plus, 869 Compact Sample Changer, 870 KF Titrino plus, 876 Dosimat plus, 877 Titrino plus, 899 Coulometer.</p> <p> </p>
    • PCS
    • 1
    • Wrench
    • 6.2739.010
    • For exchange units.
    • For exchange units.
    • PCS
    • 1
    • Exchange Unit 20 mL
    • 6.3026.220
    • Exchange unit with integrated data chip with 20 mL glass cylinder and light protection. PCTFE/PTFE flat stopcock, FEP tubing connection, anti-diffusion buret tip and standard amber glass reagent bottle.
    • <p>Exchange unit with integrated data chip with 20 mL glass cylinder and light protection. PCTFE/PTFE flat stopcock, FEP tubing connection, anti-diffusion buret tip and standard amber glass reagent bottle.</p>
    • PCS
    • 1
    • Titrino plus methods USB Stick
    • 6.6061.010
    • Contains the FOOD PAC, WINE PAC and OIL PAC methods for direct import into the Titrino plus.
    • Contains the FOOD PAC, WINE PAC and OIL PAC methods for direct import into the Titrino plus.
    • PCS
    • 1
    • Custom Q3X thermal printer
    • 2.142.0100
    • Compact printer with USB interface for 900 Touch Control; 915 KF Ti-Touch; 916 Ti-Touch; 917 Coulometer; 877 / 848 Titrino plus; 865 / 876 Dosimat plus; 91X Meter (cable 6.2151.140); Eco Dosimat / Titrator; 862 Compact Titrosampler; 870 KF Titrino plus; 899 Coulometer; Paper width 60 mm (40 characters). Including 6.2151.120 USB cable.
    • <p>Compact printer with USB interface for<br />&nbsp;</p><ul><li>900 Touch Control</li><li>915 KF Ti-Touch</li><li>916 Ti-Touch</li><li>917 Coulometer</li><li>877 / 848 Titrino plus</li><li>865 / 876 Dosimat plus</li><li>91X Meter&nbsp;(cable 6.2151.140)</li><li>Eco Dosimat / Titrator</li><li>862 Compact Titrosampler</li><li>870 KF Titrino plus</li><li>899 Coulometer</li></ul><p><br />Paper width 60&nbsp;mm (40 characters). Including 6.2151.120 USB cable.</p>
    • PCS
    • 1
    • Solvotrode
    • 6.0229.100
    • Combined pH electrode for all non-aqueous acid/base titrations. The glass membrane is optimized for poorly conducting solutions, and thanks to the flexible ground-joint diaphragm, the electrode is well suited for contaminated samples. This electrode can be used with non-aqueous reference electrolytes (lithium chloride or tetraethylammonium bromide). Storage in the respective reference electrolyte.
    • <p>Combined pH electrode for all non-aqueous acid/base titrations. The glass membrane is optimized for poorly conducting solutions, and thanks to the flexible ground-joint diaphragm, the electrode is well suited for contaminated samples. This electrode can be used with non-aqueous reference electrolytes (lithium chloride or tetraethylammonium bromide). Storage in the respective reference electrolyte.</p>
    • PCS
    • 1
    • Optrode
    • 6.1115.000
    • Optical sensor for photometric titrations offering 8 different wavelengths. The wavelength can be switched using the software (tiamo 2.5 or higher) or with a magnet. The glass shaft is completely solvent-resistant and easy to clean. For example, this space-saving sensor is suitable for:Non-aqueous titrations in accordance with USP or EP; Determinations of carboxyl end groups; TAN/TBN in accordance with ASTM D974; Sulfate determination; Fe, Al, Ca in cement; Water hardness; Chondroitin sulfate in accordance with USP; The sensor is not suitable for determinations of concentrations via measurement of color intensity (colorimetry).
    • <p>Optical sensor for photometric titrations offering 8 different wavelengths. The wavelength can be switched using the software (tiamo 2.5 or higher) or with a magnet. The glass shaft is completely solvent-resistant and easy to clean. For example, this space-saving sensor is suitable for:</p><ul><li>Non-aqueous titrations in accordance with USP or EP</li><li>Determinations of carboxyl end groups</li><li>TAN/TBN in accordance with ASTM D974</li><li>Sulfate determination</li><li>Fe, Al, Ca in cement</li><li>Water hardness</li><li>Chondroitin sulfate in accordance with USP</li></ul><p>The sensor is not suitable for determinations of concentrations via measurement of color intensity (colorimetry).</p>
    • PCS
    • 1
    • Electrode cable / 1 m / F
    • 6.2104.020
    • For connecting electrodes with Metrohm plug-in head G to Metrohm instruments (socket F).
    • For connecting electrodes with Metrohm plug-in head G to Metrohm instruments (socket F).
    • PCS
    • 1
    • Remote cable Dosimat plus - Compact Sample Changer/Titrino plus
    • 6.2141.240
    • Cable for the remote connection between Dosimat plus and Compact Sample Changer and/or Titrino plus using 6.2141.260 Cable.
    • Cable for the remote connection between Dosimat plus and Compact Sample Changer and/or Titrino plus&nbsp;using 6.2141.260 Cable.
    • PCS
    • 1
    • Remote cable Compact Sample Changer - Titrino
    • 6.2141.250
    • Cable for the remote connection between Compact Sample Changer and Titrinos with 25-pin remote socket.
    • Cable for the remote connection between Compact Sample Changer and Titrinos with 25-pin remote socket.
    • PCS
    • 1
    • Remote cable Compact Sample Changer - Dosimat plus and Titrino plus
    • 6.2141.260
    • Cable for remote connection between Compact Sample Changer and Dosimat plus and further devices (e.g. Titrino plus or Pump Station).
    • Cable for remote connection between Compact Sample Changer and Dosimat plus and further devices (e.g. Titrino plus or Pump Station).
    • PCS
    • 1
    • Exchange Unit 1 mL
    • 6.3026.110
    • Exchange Unit with integrated data chip with 1 mL glass cylinder and light protection. PCTFE/PTFE flat stopcock, FEP tubing connection, antidiffusion buret tip and standard amber glass reagent bottle.
    • Exchange Unit with integrated data chip with 1 mL glass cylinder and light protection. PCTFE/PTFE flat stopcock, FEP tubing connection, antidiffusion buret tip and standard amber glass reagent bottle.
    • PCS
    • 1
    • Exchange Unit 5 mL
    • 6.3026.150
    • Exchange Unit with integrated data chip with 5 mL glass cylinder and light protection. PCTFE/PTFE flat stopcock, FEP tubing connection, anti-diffusion buret tip and standard amber glass reagent bottle.
    • Exchange Unit with integrated data chip with 5 mL glass cylinder and light protection. PCTFE/PTFE flat stopcock, FEP tubing connection, anti-diffusion buret tip and standard amber glass reagent bottle.
    • PCS
    • 1
    • Exchange Unit 10 mL
    • 6.3026.210
    • Exchange unit with integrated data chip with 10 mL glass cylinder and light protection. PCTFE/PTFE flat stopcock, FEP tubing connection, anti-diffusion buret tip and standard amber glass reagent bottle.
    • Exchange unit with integrated data chip with 10 mL glass cylinder and light protection. PCTFE/PTFE flat stopcock, FEP tubing connection, anti-diffusion buret tip and standard amber glass reagent bottle.
    • PCS
    • 1
    • Exchange unit 50 mL
    • 6.3026.250
    • Exchange unit with integrated data chip with 50 mL glass cylinder and light protection. PCTFE/PTFE flat stopcock, FEP tubing connection, antidiffusion tip and standard amber glass reagent bottle.
    • <p>Exchange unit with integrated data chip with 50 mL glass cylinder and light protection. PCTFE/PTFE flat stopcock, FEP tubing connection, antidiffusion tip and standard amber glass reagent bottle.</p>
    • PCS
    • 1