Você foi redirecionado para a página solicitada
Metrosep C 4 - 50/4.0

Metrosep C 4 - 50/4.0

6.1050.450

Metrosep C 4 - 50/4.0

en

6.1050.450

Visão geral

The Metrosep C 4 - 50/4.0 is the shortest separation column in the Metrosep C 4 product range. With a capacity of 5 µmol (K+), it is particularly suitable for very rapid separations. The low capacity makes it possible to quickly analyze the earth alkaline metals with their delayed elution. Thanks to the short retention times, applications that, in terms of analysis duration, were previously possible only with an FIA system (Flow Injection Analysis system) can now be transferred over to ion chromatography.

Especificações técnicas

Housing materialPEEK
Carrier materialSilica gel with carboxyl groups
ManufacturerMetrohm AG
Particle size5 µm
Standard flow0.9 mL/min
Maximum pressure25 MPa
Maximum flow2.0 mL/min
pH range2–7
Column dimensions 4.0 x  50 mm
Temperature range20–60 °C

Cromatograma

  • Cromatograma
  • Cromatograma
  • Cromatograma
Este campo é obrigatório.
    • Threaded stopper
    • 6.2744.060
    • For UNF 10/32. Stopper for IC, e.g. for the sealing of columns.
    • <p>For UNF 10/32. Stopper for IC, e.g. for the sealing of columns.</p>
    • PCS
    • 2
    • Threaded stopper
    • 6.2744.060
    • For UNF 10/32. Stopper for IC, e.g. for the sealing of columns.
    • <p>For UNF 10/32. Stopper for IC, e.g. for the sealing of columns.</p>
    • PCS
    • 2
    • Metrosep C 4 Guard/4.0
    • 6.1050.500
    • The Metrosep C 4 Guard/4.0 contains the C-4 column material and is used to protect all Metrosep cation columns that have a substrate based on silica gel. Particles and contamination are reliably retained, considerably prolonging the service life of the analytical separation column. The economical price is an additional plus. The Metrosep C 4 Guard/4.0 also works based on the "On Column Guard System" and is screwed directly onto the separation column with virtually no dead volume.
    • <p>The Metrosep C 4 Guard/4.0 contains the C-4 column material and is used to protect all Metrosep cation columns that have a substrate based on silica gel. Particles and contamination are reliably retained, considerably prolonging the service life of the analytical separation column. The economical price is an additional plus. The Metrosep C 4 Guard/4.0 also works based on the "On Column Guard System" and is screwed directly onto the separation column with virtually no dead volume.</p>
    • PCS
    • 1
    • Metrosep C 4 S-Guard/4.0
    • 6.1050.510
    • The Metrosep C 4 S-Guard/4.0 contains the C-4 column material and is used to protect all Metrosep cation columns that have a substrate based on silica gel. Particles and contamination are reliably retained, considerably prolonging the service life of the analytical separation column. The economical price is an additional plus.
    • <p>The Metrosep C 4 S-Guard/4.0 contains the C-4 column material and is used to protect all Metrosep cation columns that have a substrate based on silica gel. Particles and contamination are reliably retained, considerably prolonging the service life of the analytical separation column. The economical price is an additional plus.</p>
    • PCS
    • 1