Accessing battery material properties with electrochemical techniques

52 min

en

// Energy

Dr. Christoffer Karlsson, Senior R&D Scientist at rhd instruments, presents electrochemical impedance spectroscopy (EIS) measurements, focusing on battery component properties such as the MacMullin number of separators, tortuosity of active material coatings, and electrolyte conductivity. He also discusses a workflow for simple and reliable impedance data fitting and parameter evaluation.

NOR Web Form - Gated Video new
Fyll ut feltene for å se webinaret vårt. Feltene merket (*) må fylles ut.
 
 
 
 
Fornavn*
 
 
Etternavn*
 
 
 
e-post*
 
 
Land*
 
 
 
Firma
 
 
 
 
Jeg godkjenner at Metrohm Nordic AS lagrer data jeg har oppgitt i henhold til Metrohms retningslinjer for personvern og kan kontakte meg på e-post, telefon og pr. post. Jeg kan når som helst trekke tilbake denne godkjennelsen ved å sende en e-post til firmapost@metrohm.no.

  
 
Jeg aksepterer Metrohm Nordics retningslinjer for personvern*
 
 
 


Ikke gå glipp av Metrohms gode tilbud og spesialrabatter. Abonner på vårt nyhetsbrev her.

  
 
Jeg ønsker å motta nyhetsbrev fra Metrohm Nordic
 
 
 
 
 
 
 
 
 
Webinar ID
 
 
 
 
 
 
 

Electrochemical Impedance Spectroscopy: Detailed information about complex systems

Electrochemical Impedance Spectroscopy (EIS)

Electrochemical impedance spectroscopy (EIS) is a widely used multidisciplinary technique for characterizing the behavior of complex electrochemical systems. EIS performed on cells containing only the essential components can provide detailed information about each part of the device. This approach allows for a clearer distinction of each component's contribution to the overall performance. It also helps explain the electrochemical behavior of the complete system.

Watch the webinar to learn:

  • about device components of lithium-ion batteries
  • how to determine conductivity, MacMullin number, tortuosity electrolytes by EIS
  • how to set up a test cell for component analysis