Du har blitt omdirigert til din lokale versjon av den forespurte siden
815 Robotic Soliprep for LC

815 Robotic Soliprep for LC

2.815.4110

    • Sample beaker, clear glass, 250 mL, 1 piece 
    • 6.1432.320
    • Sample beaker, clear glass, 250 mL, suitable for sample racks: 6.2041.310, 6.2041.400, 6.2041.430, 6.2041.510, 6.2041.820, 6.2068.020 and 6.2068.030, 1 piece 
    • <p>Sample beaker, clear glass, 250 mL, suitable for sample racks: 6.2041.310, 6.2041.400, 6.2041.430, 6.2041.510, 6.2041.820, 6.2068.020 and 6.2068.030, 1 piece<br/> </p>
    • PCS
    • 2
    • Sample beaker, plastic (PP), 120 mL, 250 pieces 
    • 6.1459.300
    • Sample beaker, plastic (polypropylene, PP), 120 mL, suitable for sample racks: 6.2041.470, 6.2041.840, 6.2041.850, 6.2068.010, 6.2068.020, 6.2068.030, and 6.9920.141, 250 pieces 
    • <p>Sample beaker, plastic (polypropylene, PP), 120 mL, suitable for sample racks: 6.2041.470, 6.2041.840, 6.2041.850, 6.2068.010, 6.2068.020, 6.2068.030, and 6.9920.141, 250 pieces<br/> </p>
    • PCS
    • 1
    • Transfer head for 786 Swing Head, bent and right swinging
    • 6.1462.240
    • Transfer head, bent and right swinging, for 786 Swing Head. In combination with the 6.1808.220 Adapter the transfer head can be used on multi-row racks to pick up tools with luer connection.
    • Transfer head, bent and right swinging, for 786 Swing Head. In combination with the 6.1808.220 Adapter the transfer head can be used on multi-row racks to pick up tools with luer connection.
    • PCS
    • 1
    • Swing arm for Polytron and 786 Swing Head, left swinging
    • 6.1462.250
    • Swing arm for Polytron and 786 Swing Head, left swinging, with one buret tip for the additiona of solvent or titrant and three spray nozzles for cleaning. The swing arm allows the usage of the Polytron for sample preparation on multi row racks.
    • Swing arm for Polytron and 786 Swing Head, left swinging, with one buret tip for the additiona of solvent or titrant and three spray nozzles for cleaning. The swing arm allows the usage of the Polytron for sample preparation on multi row racks.
    • PCS
    • 1
    • Piston tongs
    • 6.1546.030
    • For pistons for 807 Dosing Units or cylinder units OMNIS.
    • <p>For pistons for 807 Dosing Units or cylinder units OMNIS.</p>
    • PCS
    • 1
    • Container 10 L
    • 6.1621.000
    • As rinsing or waste container in automated systems.
    • As rinsing or waste container in automated systems.
    • PCS
    • 3
    • Collection container for Soliprep
    • 6.1625.010
    • Container for safe collection of used tools in automated systems
    • Container for safe collection of used tools in automated systems
    • PCS
    • 1
    • PTFE capillary 0.5 mm i.d. / 3 m
    • 6.1803.030
    • Capillary for inline dialysis, for Dialysis Unit, IC Dialysis Sample Processor, IC Liquid Handling Dialysis Unit
    • Capillary for inline dialysis, for Dialysis Unit, IC Dialysis Sample Processor, IC Liquid Handling Dialysis Unit
    • PCS
    • 1
    • Luer adapter for transfer head
    • 6.1808.220
    • Adapter with outside thread M6 and luer connection for 6.1462.240 Transfer head for using luer tools on multi-row racks
    • Adapter with outside thread M6 and luer connection for&nbsp;6.1462.240 Transfer head for using luer tools on multi-row racks
    • PCS
    • 1
    • M10/M6 adapter
    • 6.1820.020
    • Connector with M10 thread for 6.1812.XXX tubing and M6 thread for 6.1805.XXX tubing.
    • Connector with M10 thread for 6.1812.XXX tubing and M6 thread for 6.1805.XXX tubing.
    • PCS
    • 1
    • M6 / Olive adapter
    • 6.1820.050
    • For 6.1826.100 pump tubing, to peristaltic pumps.
    • <p>For 6.1826.100 pump tubing, to peristaltic pumps.</p>
    • PCS
    • 2
    • Pump tubing 6.4 mm / 1 m
    • 6.1826.100
    • Replaces the pump tubing used with the 772 Pump Unit and the 843 Pump Station (peristaltic).
    • <p>Replaces the pump tubing used with the 772 Pump Unit and the 843 Pump Station (peristaltic).</p>
    • PCS
    • 1
    • Lid with hole for 250 mL sample beaker
    • 6.2037.070
    • The lid with hole is used in the Soliprep system to pre-rinse applied syringe filters into the special beaker.
    • The lid with hole is used in the Soliprep system to pre-rinse applied syringe filters into the special beaker.
    • PCS
    • 1
    • Cable clip
    • 6.2053.000
    • Cable clip for fastening cables and tubes
    • Cable clip for fastening cables and tubes
    • PCS
    • 2
    • Swing arm enhancement for Swing Head 786
    • 6.2058.040
    • The swing arm enhancement is for stabilizing the swing arm connected to the 786 Swing Head and working with various tools
    • The swing arm enhancement is for stabilizing the swing arm connected to the 786 Swing Head and working with various tools
    • PCS
    • 1
    • Fastening plate for deflector and holder for collection container
    • 6.2058.050
    • The fastening plate is mounted at the side of the Sample Processor tower and allows the mounting of a deflector for the automatic pulling off the used tools.
    • The fastening plate is mounted at the side of the Sample Processor tower and allows the mounting of a deflector for the automatic pulling off the used tools.
    • PCS
    • 1
    • Deflector for adapter 61808220
    • 6.2058.060
    • The deflector is mounted with the fastening plate (6.2058.050) at the side of the Sample Processor tower and allows the automatic pulling off the used luer tools into the collection container (6.1625.010)
    • The deflector is mounted with&nbsp;the fastening plate (6.2058.050) at the side of the Sample Processor tower and allows the automatic pulling off the used luer tools into the collection container (6.1625.010)
    • PCS
    • 1
    • Sample rack, 24 x 120 mL, (PVC)
    • 6.2068.020
    • Sample rack for 815 Robotic Soliprep, suitable for 24 sample beakers. The following sample beakers can be used: 6.1459.300, 6.1459.307.Plastic: Polyvinyl chloride (PVC)
    • <p>Sample rack for 815 Robotic Soliprep, suitable for 24 sample beakers. The following sample beakers can be used: 6.1459.300, 6.1459.307.</p><p>Plastic: Polyvinyl chloride (PVC)</p>
    • PCS
    • 1
    • Cable RS-232 DB9 socket f – DB9 plug
    • 6.2134.110
    • Connecting Metrohm RS-232 interface (DB9) to a Custom DP40 printer. For Titrinos or 756/831 KF Coulometer. RS-232 extension cable (1:1)
    • Connecting Metrohm RS-232 interface (DB9) to a Custom DP40 printer. For Titrinos or 756/831 KF Coulometer. RS-232 extension cable (1:1)
    • PCS
    • 1
    • Drip pan for 789/815/855
    • 6.2711.070
    • Drip pan for 789, 815, 855 Robotic Sample Processors XL
    • Drip pan for 789, 815, 855 Robotic Sample Processors XL
    • PCS
    • 1
    • Spray nozzle
    • 6.2740.020
    • For the fine-spraying of the rinsing solution.
    • <p>For the fine-spraying of the rinsing solution.</p>
    • PCS
    • 3
    • Sample vessel 11 mL
    • 6.2743.057
    • 200 pieces. For IC Sample Processors and VA Autosamplers.The IC sample vessels are made of polypropylene (PP) plastic for health-care applications. Production and packaging both take place under sterile and clean room conditions (Clean Room Class 7, in accordance with DIN ISO 14644). This guarantees minimal degrees of contamination. The sample vessels are subjected to random checks for leachable anions and cations.
    • <p>200 pieces. For IC Sample Processors and VA Autosamplers.</p><p>The IC sample vessels are made of polypropylene (PP) plastic for health-care applications. Production and packaging both take place under sterile and clean room conditions (Clean Room Class 7, in accordance with DIN ISO 14644). This guarantees minimal degrees of contamination. The sample vessels are subjected to random checks for leachable anions and cations.</p>
    • PCS
    • 1
    • Pressure screw 2x
    • 6.2744.014
    • With UNF 10/32 connection. For the connection of PEEK capillaries
    • With UNF 10/32 connection. For the connection of PEEK capillaries
    • PCS
    • 1
    • Safety shield for Robotic Soliprep
    • 6.2751.150
    • Safety shield for the Robotic Soliprep systems Filtration and Flexible, which pick up and then discard various tools at Tower 1, e.g. syringe needles. Reaching into the movement radius of the robotic arm is prevented and at the same time protection is offered against inadvertently escaping solutions.
    • <p>Safety shield for the Robotic Soliprep systems Filtration and Flexible, which pick up and then discard various tools at Tower 1, e.g. syringe needles. Reaching into the movement radius of the robotic arm is prevented and at the same time protection is offered against inadvertently escaping solutions.</p>
    • PCS
    • 1
    • External Polytron rinsing station for Robotic Sample Processors
    • 6.2841.000
    • The external rinsing station can be fitted on the side next to the Robotic Sample Processor tower, making it possible for external cleaning of the Polytron to be carried out during additional actions on the sample rack.
    • <p>The external rinsing station can be fitted on the side next to the Robotic Sample Processor tower, making it possible for external cleaning of the Polytron to be carried out during additional actions on the sample rack.</p>
    • PCS
    • 1
    • 807 Dosing Unit 10 mL
    • 6.3032.210
    • 807 Dosing Unit with integrated data chip with 10 mL glass cylinder and light protection, mountable to a reagent bottle with ISO/DIN GL 45 glass thread. FEP tubing connection, antidiffusion tip.
    • <p>807 Dosing Unit with integrated data chip with 10 mL glass cylinder and light protection, mountable to a reagent bottle with ISO/DIN GL 45 glass thread. FEP tubing connection, antidiffusion tip.</p>
    • PCS
    • 1
    • 807 Dosing Unit 50 mL
    • 6.3032.250
    • 807 Dosing Unit with integrated data chip with 50 mL glass cylinder and light protection, mountable to a reagent bottle with ISO/DIN GL 45 glass thread. FEP tubing connection, antidiffusion tip.
    • <p>807 Dosing Unit with integrated data chip with 50 mL glass cylinder and light protection, mountable to a reagent bottle with ISO/DIN GL 45 glass thread. FEP tubing connection, antidiffusion tip.</p>
    • PCS
    • 1
    • Polytron PT 1300 D
    • 1.136.0100
    • Polytron PT 1300 D - Metrohm versionHomogenizer that can be controlled directly by tiamo™ or Touch Control.
    • <p>Polytron PT 1300 D - Metrohm version</p><p>Homogenizer that can be controlled directly by<strong> tiamo</strong>&trade; or Touch Control.</p>
    • PCS
    • 1
    • 772 Pump Unit
    • 1.772.0110
    • Peristaltic pump for direct connection to Sample Processors.
    • Peristaltic pump for direct connection to Sample Processors.
    • PCS
    • 1
    • 786 Swing Head with transfer head left
    • 1.786.0010
    • Additional equipment for Robotic Sample Processors XL for transferring / pipetting from small sample vessels into larger titration vessels on the rack or into an external titration cell; this can be located to the left of the work station.
    • Additional equipment for Robotic Sample Processors XL for transferring / pipetting from small sample vessels into larger titration vessels on the rack or into an external titration cell; this can be located to the left of the work station.
    • PCS
    • 1
    • 800 Dosino (cable length 1.5 m)
    • 1.800.0030
    • Drive with write/read hardware for intelligent dosing units. With permanently attached cable (length 1.5 m).
    • <p>Drive with write/read hardware for intelligent dosing units. With permanently attached cable (length 1.5 m).</p>
    • PCS
    • 2
    • 815 Robotic USB Sample Processor XL (2T/2P)
    • 1.815.0110
    • Robotic USB Sample Processor XL with two workstations and two built-in membrane pumps for the automatic processing of routine samples in series with large quantities and for complex sample preparation or parallel runs. In addition to the built-in pumps, up to two additional pumps (membrane or peristaltic) and three dosing devices for Liquid Handling tasks can be connected.Because of the multitude of application variants, rack, stirrer, titration head, robotic arm, Swing Head and sample vessels must be tailored to the application and ordered separately.
    • <p>Robotic USB Sample Processor XL with two workstations and two built-in membrane pumps for the automatic processing of routine samples in series with large quantities and for complex sample preparation or parallel runs. In addition to the built-in pumps, up to two additional pumps (membrane or peristaltic) and three dosing devices for Liquid Handling tasks can be connected.<br/> <br/>Because of the multitude of application variants, rack, stirrer, titration head, robotic arm, Swing Head and sample vessels must be tailored to the application and ordered separately.</p>
    • PCS
    • 1
    • Sample beaker, clear glass, 250 mL, 1 piece 
    • 6.1432.320
    • Sample beaker, clear glass, 250 mL, suitable for sample racks: 6.2041.310, 6.2041.400, 6.2041.430, 6.2041.510, 6.2041.820, 6.2068.020 and 6.2068.030, 1 piece 
    • <p>Sample beaker, clear glass, 250 mL, suitable for sample racks: 6.2041.310, 6.2041.400, 6.2041.430, 6.2041.510, 6.2041.820, 6.2068.020 and 6.2068.030, 1 piece<br/> </p>
    • PCS
    • 2
    • Sample beaker, plastic (PP), 120 mL, 250 pieces 
    • 6.1459.300
    • Sample beaker, plastic (polypropylene, PP), 120 mL, suitable for sample racks: 6.2041.470, 6.2041.840, 6.2041.850, 6.2068.010, 6.2068.020, 6.2068.030, and 6.9920.141, 250 pieces 
    • <p>Sample beaker, plastic (polypropylene, PP), 120 mL, suitable for sample racks: 6.2041.470, 6.2041.840, 6.2041.850, 6.2068.010, 6.2068.020, 6.2068.030, and 6.9920.141, 250 pieces<br/> </p>
    • PCS
    • 1
    • Transfer head for 786 Swing Head, bent and right swinging
    • 6.1462.240
    • Transfer head, bent and right swinging, for 786 Swing Head. In combination with the 6.1808.220 Adapter the transfer head can be used on multi-row racks to pick up tools with luer connection.
    • Transfer head, bent and right swinging, for 786 Swing Head. In combination with the 6.1808.220 Adapter the transfer head can be used on multi-row racks to pick up tools with luer connection.
    • PCS
    • 1
    • Swing arm for Polytron and 786 Swing Head, left swinging
    • 6.1462.250
    • Swing arm for Polytron and 786 Swing Head, left swinging, with one buret tip for the additiona of solvent or titrant and three spray nozzles for cleaning. The swing arm allows the usage of the Polytron for sample preparation on multi row racks.
    • Swing arm for Polytron and 786 Swing Head, left swinging, with one buret tip for the additiona of solvent or titrant and three spray nozzles for cleaning. The swing arm allows the usage of the Polytron for sample preparation on multi row racks.
    • PCS
    • 1
    • Piston tongs
    • 6.1546.030
    • For pistons for 807 Dosing Units or cylinder units OMNIS.
    • <p>For pistons for 807 Dosing Units or cylinder units OMNIS.</p>
    • PCS
    • 1
    • Container 10 L
    • 6.1621.000
    • As rinsing or waste container in automated systems.
    • As rinsing or waste container in automated systems.
    • PCS
    • 3
    • Collection container for Soliprep
    • 6.1625.010
    • Container for safe collection of used tools in automated systems
    • Container for safe collection of used tools in automated systems
    • PCS
    • 1
    • PTFE capillary 0.5 mm i.d. / 3 m
    • 6.1803.030
    • Capillary for inline dialysis, for Dialysis Unit, IC Dialysis Sample Processor, IC Liquid Handling Dialysis Unit
    • Capillary for inline dialysis, for Dialysis Unit, IC Dialysis Sample Processor, IC Liquid Handling Dialysis Unit
    • PCS
    • 1
    • Luer adapter for transfer head
    • 6.1808.220
    • Adapter with outside thread M6 and luer connection for 6.1462.240 Transfer head for using luer tools on multi-row racks
    • Adapter with outside thread M6 and luer connection for&nbsp;6.1462.240 Transfer head for using luer tools on multi-row racks
    • PCS
    • 1
    • M10/M6 adapter
    • 6.1820.020
    • Connector with M10 thread for 6.1812.XXX tubing and M6 thread for 6.1805.XXX tubing.
    • Connector with M10 thread for 6.1812.XXX tubing and M6 thread for 6.1805.XXX tubing.
    • PCS
    • 1
    • M6 / Olive adapter
    • 6.1820.050
    • For 6.1826.100 pump tubing, to peristaltic pumps.
    • <p>For 6.1826.100 pump tubing, to peristaltic pumps.</p>
    • PCS
    • 2
    • Pump tubing 6.4 mm / 1 m
    • 6.1826.100
    • Replaces the pump tubing used with the 772 Pump Unit and the 843 Pump Station (peristaltic).
    • <p>Replaces the pump tubing used with the 772 Pump Unit and the 843 Pump Station (peristaltic).</p>
    • PCS
    • 1
    • Lid with hole for 250 mL sample beaker
    • 6.2037.070
    • The lid with hole is used in the Soliprep system to pre-rinse applied syringe filters into the special beaker.
    • The lid with hole is used in the Soliprep system to pre-rinse applied syringe filters into the special beaker.
    • PCS
    • 1
    • Cable clip
    • 6.2053.000
    • Cable clip for fastening cables and tubes
    • Cable clip for fastening cables and tubes
    • PCS
    • 2
    • Swing arm enhancement for Swing Head 786
    • 6.2058.040
    • The swing arm enhancement is for stabilizing the swing arm connected to the 786 Swing Head and working with various tools
    • The swing arm enhancement is for stabilizing the swing arm connected to the 786 Swing Head and working with various tools
    • PCS
    • 1
    • Fastening plate for deflector and holder for collection container
    • 6.2058.050
    • The fastening plate is mounted at the side of the Sample Processor tower and allows the mounting of a deflector for the automatic pulling off the used tools.
    • The fastening plate is mounted at the side of the Sample Processor tower and allows the mounting of a deflector for the automatic pulling off the used tools.
    • PCS
    • 1
    • Deflector for adapter 61808220
    • 6.2058.060
    • The deflector is mounted with the fastening plate (6.2058.050) at the side of the Sample Processor tower and allows the automatic pulling off the used luer tools into the collection container (6.1625.010)
    • The deflector is mounted with&nbsp;the fastening plate (6.2058.050) at the side of the Sample Processor tower and allows the automatic pulling off the used luer tools into the collection container (6.1625.010)
    • PCS
    • 1
    • Sample rack, 24 x 120 mL, (PVC)
    • 6.2068.020
    • Sample rack for 815 Robotic Soliprep, suitable for 24 sample beakers. The following sample beakers can be used: 6.1459.300, 6.1459.307.Plastic: Polyvinyl chloride (PVC)
    • <p>Sample rack for 815 Robotic Soliprep, suitable for 24 sample beakers. The following sample beakers can be used: 6.1459.300, 6.1459.307.</p><p>Plastic: Polyvinyl chloride (PVC)</p>
    • PCS
    • 1
    • Cable RS-232 DB9 socket f – DB9 plug
    • 6.2134.110
    • Connecting Metrohm RS-232 interface (DB9) to a Custom DP40 printer. For Titrinos or 756/831 KF Coulometer. RS-232 extension cable (1:1)
    • Connecting Metrohm RS-232 interface (DB9) to a Custom DP40 printer. For Titrinos or 756/831 KF Coulometer. RS-232 extension cable (1:1)
    • PCS
    • 1
    • Drip pan for 789/815/855
    • 6.2711.070
    • Drip pan for 789, 815, 855 Robotic Sample Processors XL
    • Drip pan for 789, 815, 855 Robotic Sample Processors XL
    • PCS
    • 1
    • Spray nozzle
    • 6.2740.020
    • For the fine-spraying of the rinsing solution.
    • <p>For the fine-spraying of the rinsing solution.</p>
    • PCS
    • 3
    • Sample vessel 11 mL
    • 6.2743.057
    • 200 pieces. For IC Sample Processors and VA Autosamplers.The IC sample vessels are made of polypropylene (PP) plastic for health-care applications. Production and packaging both take place under sterile and clean room conditions (Clean Room Class 7, in accordance with DIN ISO 14644). This guarantees minimal degrees of contamination. The sample vessels are subjected to random checks for leachable anions and cations.
    • <p>200 pieces. For IC Sample Processors and VA Autosamplers.</p><p>The IC sample vessels are made of polypropylene (PP) plastic for health-care applications. Production and packaging both take place under sterile and clean room conditions (Clean Room Class 7, in accordance with DIN ISO 14644). This guarantees minimal degrees of contamination. The sample vessels are subjected to random checks for leachable anions and cations.</p>
    • PCS
    • 1
    • Pressure screw 2x
    • 6.2744.014
    • With UNF 10/32 connection. For the connection of PEEK capillaries
    • With UNF 10/32 connection. For the connection of PEEK capillaries
    • PCS
    • 1
    • Safety shield for Robotic Soliprep
    • 6.2751.150
    • Safety shield for the Robotic Soliprep systems Filtration and Flexible, which pick up and then discard various tools at Tower 1, e.g. syringe needles. Reaching into the movement radius of the robotic arm is prevented and at the same time protection is offered against inadvertently escaping solutions.
    • <p>Safety shield for the Robotic Soliprep systems Filtration and Flexible, which pick up and then discard various tools at Tower 1, e.g. syringe needles. Reaching into the movement radius of the robotic arm is prevented and at the same time protection is offered against inadvertently escaping solutions.</p>
    • PCS
    • 1
    • External Polytron rinsing station for Robotic Sample Processors
    • 6.2841.000
    • The external rinsing station can be fitted on the side next to the Robotic Sample Processor tower, making it possible for external cleaning of the Polytron to be carried out during additional actions on the sample rack.
    • <p>The external rinsing station can be fitted on the side next to the Robotic Sample Processor tower, making it possible for external cleaning of the Polytron to be carried out during additional actions on the sample rack.</p>
    • PCS
    • 1
    • 807 Dosing Unit 10 mL
    • 6.3032.210
    • 807 Dosing Unit with integrated data chip with 10 mL glass cylinder and light protection, mountable to a reagent bottle with ISO/DIN GL 45 glass thread. FEP tubing connection, antidiffusion tip.
    • <p>807 Dosing Unit with integrated data chip with 10 mL glass cylinder and light protection, mountable to a reagent bottle with ISO/DIN GL 45 glass thread. FEP tubing connection, antidiffusion tip.</p>
    • PCS
    • 1
    • 807 Dosing Unit 50 mL
    • 6.3032.250
    • 807 Dosing Unit with integrated data chip with 50 mL glass cylinder and light protection, mountable to a reagent bottle with ISO/DIN GL 45 glass thread. FEP tubing connection, antidiffusion tip.
    • <p>807 Dosing Unit with integrated data chip with 50 mL glass cylinder and light protection, mountable to a reagent bottle with ISO/DIN GL 45 glass thread. FEP tubing connection, antidiffusion tip.</p>
    • PCS
    • 1
    • Sample rack 65 x 11 mL + 25 x 50 mL
    • 6.2041.780
    • Multi-row sample rack for 65 samples in 11 mL sample vessels (6.2743.050) and 25 samples in 50 mL sample vessels (6.02743.030)
    • <p>Multi-row sample rack for 65 samples in 11 mL sample vessels (6.2743.050) and 25 samples in 50 mL sample vessels (6.02743.030)</p>
    • PCS
    • 1