特長
水性酸/塩基滴定のためのNS 14/15のすり合わせ、内蔵型Pt1000温度センサーおよび固定式ケーブル (1.2 m、バナナプラグ 2 mm) 付き複合pH電極。
参照内部液: c(KCl) = 3 mol / L、保存液で保管。
技術仕様
| SGJ sleeve | すり合わせ 14/15 |
|---|---|
| Membrane glass type | T |
| Resistance (kOhm) | 3 |
| Shaft material | Glass |
| Measuring range (theoretical) | 0 ... 14 |
| Measuring unit | pH |
| Temperature range, long-term (°C) | 0 ... 80 |
| Temperature range, short-term (°C) | 0 ... 80 |
| Shaft diameter top (mm) | 12 |
| Shaft diameter bottom (mm) | 12 |
| Min. immersion depth (mm) | 20 |
| Electrode plug-in head | Fixed cable (l = 1.2 m) with plug F + 2 x B |
| Indicator electrode type | Glass electrode |
| Indicator electrode shape | Hemisphere |
| Membrane resistance | 150 ... 400 |
| Electrode zero point (mV) | 0 ± 15 mV (pH = 7) |
| Electrode slope | > 0.97 |
| Temperature sensor | Pt1000 |
| Internal reference electrode type | LL system |
| Diaphragm | Ceramic pin |
| Reference electrolyte type | c(KCl) = 3 mol/L |
| Bridge electrolyte type | c(KCl) = 3 mol/L |
こちらの製品は販売終了していますが、サポートは継続しています。
代替製品
-
- 保存容器
- 6.2008.040
- ホルダー 6.2008.050 とともに使用すると 807 Dosing Unit の電極用のホルダーになります。
- <p>ホルダー 6.2008.050 とともに使用すると 807 Dosing Unit の電極用のホルダーになります。</p>
- PCS
- 1
-
- 保存容器
- 6.2008.040
- ホルダー 6.2008.050 とともに使用すると 807 Dosing Unit の電極用のホルダーになります。
- <p>ホルダー 6.2008.050 とともに使用すると 807 Dosing Unit の電極用のホルダーになります。</p>
- PCS
- 1
-
- Storage solution
- 6.2323.000
- Storage solution for all combined pH glass electrodes with reference electrolyte c(KCl) = 3 mol/L
- PCS
- 1
- Electrolyte 3 mol/L KCl (250 mL)
- 6.2308.020
- Electrolyte solution c(KCl) = 3 mol/L, (for Ag/AgCl reference systems)
- PCS
- 1
- pHit kit
- 6.2325.000
- Maintenance kit for pH electrodes The kit contains:50 mL cleaning solution; 50 mL 3M KCl solution; 50 mL storage solution; 2 Storage vessels; Instructions for use;
- PCS
- 1
- 洗浄液 3 x 50 mL
- 6.2325.100
- Reliable measuring results over long periods of time can be guaranteed only if the pH glass membrane and the diaphragm receive preventive and regular care. Cleaning by etching with toxic chemicals or applying mechanical treatment to the diaphragm is not only complicated and expensive, it also accelerates the ageing of the pH glass electrode.The cleaning solution was developed for easy and gentle cleaning of pH glass electrodes. Regular use can considerably prolong their service life.This cleaning solution is also part of the pHit kit.
- PCS
- 1
- Adapter red 4 mm plug / 2 mm soc
- 6.2103.150
- Adapter for connecting electrodes with 2 mm plug to instruments with 4 mm socket (banana)
- PCS
- 1