Ecotrode
6.0232.100
Ecotrode
ja
6.0232.100
特長
水性酸/塩基滴定のための複合pH 電極。
参照内部液: c(KCl) = 3 mol/L、保存液で保管。
技術仕様
| SGJ sleeve | フレキシブルな摺り接手 |
|---|---|
| Membrane glass type | T |
| Resistance (kOhm) | 3 |
| Shaft material | Glass |
| Measuring range (theoretical) | 0 ... 14 |
| Measuring unit | pH |
| Temperature range, long-term (°C) | 0 ... 80 |
| Temperature range, short-term (°C) | 0 ... 80 |
| Max. installation length (mm) | 125 |
| Shaft diameter top (mm) | 12 |
| Shaft diameter bottom (mm) | 12 |
| Min. immersion depth (mm) | 20 |
| Electrode plug-in head | Metrohm plug-in head G |
| Indicator electrode type | Glass electrode |
| Indicator electrode shape | Hemisphere |
| Membrane resistance | 150 ... 400 |
| Electrode zero point (mV) | 0 ± 15 mV (pH = 7) |
| Electrode slope | > 0.97 |
| Asymmetry potential | ± 15 |
| Internal reference electrode type | LL system |
| Diaphragm | Ceramic pin |
| Reference electrolyte type | c(KCl) = 3 mol/L |
| Bridge electrolyte type | c(KCl) = 3 mol/L |
| Electrolyte flow rate (μl/h) at 10 cm water column | 10 ... 25 |
| Reference system | LL system |
こちらの製品は販売終了していますが、サポートは継続しています。
代替製品
-
- Sleeve with SGJ 14/12 mm
- 6.1236.050
- Sleeve with SGJ 14/12 mm, polyethylene.
- PCS
- 1
- 保存容器
- 6.2008.040
- ホルダー 6.2008.050 とともに使用すると 807 Dosing Unit の電極用のホルダーになります。
- <p>ホルダー 6.2008.050 とともに使用すると 807 Dosing Unit の電極用のホルダーになります。</p>
- PCS
- 1
-
- Sleeve with SGJ 14/12 mm
- 6.1236.050
- Sleeve with SGJ 14/12 mm, polyethylene.
- PCS
- 1
- 保存容器
- 6.2008.040
- ホルダー 6.2008.050 とともに使用すると 807 Dosing Unit の電極用のホルダーになります。
- <p>ホルダー 6.2008.050 とともに使用すると 807 Dosing Unit の電極用のホルダーになります。</p>
- PCS
- 1
-
- Electrolyte 3 mol/L KCl (250 mL)
- 6.2308.020
- Electrolyte solution c(KCl) = 3 mol/L, (for Ag/AgCl reference systems)
- PCS
- 1
- Storage solution
- 6.2323.000
- Storage solution for all combined pH glass electrodes with reference electrolyte c(KCl) = 3 mol/L
- PCS
- 1
- pHit kit
- 6.2325.000
- Maintenance kit for pH electrodes The kit contains:50 mL cleaning solution; 50 mL 3M KCl solution; 50 mL storage solution; 2 Storage vessels; Instructions for use;
- PCS
- 1
- 洗浄液 3 x 50 mL
- 6.2325.100
- Reliable measuring results over long periods of time can be guaranteed only if the pH glass membrane and the diaphragm receive preventive and regular care. Cleaning by etching with toxic chemicals or applying mechanical treatment to the diaphragm is not only complicated and expensive, it also accelerates the ageing of the pH glass electrode.The cleaning solution was developed for easy and gentle cleaning of pH glass electrodes. Regular use can considerably prolong their service life.This cleaning solution is also part of the pHit kit.
- PCS
- 1
- Electrode cable / 1 m / F
- 6.2104.020
- For connecting electrodes with Metrohm plug-in head G to Metrohm instruments (socket F).
- PCS
- 1