Unitrode with Pt1000
6.0258.600
Unitrode with Pt1000
en
6.0258.600
Feature overview
Combined pH electrode with integrated Pt1000 temperature sensor for pH measurements/titrations. This electrode is particularly suitable:
- for pH measurements and titrations in difficult, viscous, or alkaline samples
- at elevated temperatures
- for long-term measurements
The fixed ground-joint diaphragm is insensitive to contamination.
Reference electrolyte: c(KCl) = 3 mol/L, storage in storage solution.
Alternatively: reference electrolyte for measurements at T>80°C: Idrolyte, storage in Idrolyte.
Tech specs
| Shaft material | Glass |
|---|---|
| Measuring unit | pH |
| Temperature range, long-term (°C) | 0 ... 80 |
| Temperature range, short-term (°C) | 0 ... 100 |
| pH range | 0...14 |
| Max. installation length (mm) | 125 |
| SGJ sleeve | Flexible SGJ sleeve |
| Shaft diameter top (mm) | 12 |
| Shaft diameter bottom (mm) | 12 |
| Min. immersion depth (mm) | 25 |
| Electrode plug-in head | Metrohm plug-in head U |
| Temperature sensor | Pt1000 |
| Indicator electrode shape | Cylinder |
| Membrane glass type | U |
| Membrane resistance | 150...500 |
| Electrode zero point (mV) | ±15 |
| Electrode slope | >0.97 |
| Diaphragm | Fixed ground-joint diaphragm |
| Reference electrolyte type | c(KCl) = 3 mol/L |
| Electrolyte flow rate (μl/h) at 10 cm water column | 5...30 |
| Reference system | LL system |
| Resistance (kOhm) | 5 |
Documents
-
80005422
-
en
- title
- Metrosensor electrodes
- description
- Metrohm offers a large selection of sensors for a wide range of applications. This catalog provides you with an overview of all Metrosensor electrodes.The main chapters include:Which electrode for which application?; Metrosensor electrodes - an overview; Accessories; How is a Metrosensor made?; Theoretical fundamentals; Technical specifications;
- language
- en
- documentpath
- /content/metrohm/shared/en/products/8/0005/80005422
-
vi
- title
- Metrosensor electrodes
- description
- Metrohm offers a large selection of sensors for a wide range of applications. This catalog provides you with an overview of all Metrosensor electrodes.The main chapters include:Which electrode for which application?; Metrosensor electrodes - an overview; Accessories; How is a Metrosensor made?; Theoretical fundamentals; Technical specifications;
- language
- vi
- documentpath
- /content/metrohm/shared/vi/products/8/0005/80005422
-
en
-
81081176
-
de
- title
- Beilage – Festsitzende Elektrode lösen
- description
- language
- de
- documentpath
- /content/metrohm/shared/de/products/8/1081/81081176
-
en
- title
- Supplement – loosening a stuck electrode
- description
- language
- en
- documentpath
- /content/metrohm/shared/en/products/8/1081/81081176
-
fr
- title
- Supplément - desserrer une électrode coincée
- description
- language
- fr
- documentpath
- /content/metrohm/shared/fr/products/8/1081/81081176
-
vi
- title
- Supplement – loosening a stuck electrode
- description
- language
- vi
- documentpath
- /content/metrohm/shared/vi/products/8/1081/81081176
-
de
-
81095001
-
de
- title
- Prospekt: 6.0258.600 Unitrode mit Steckkopf U
- description
- Die bewährte Unitrode mit Pt 1000-Temperaturfühler jetzt auch mit abnehmbaren Elektrodenkabel. Die Vorteile auf einem Blick:Preisvorteil: Niedrigerer Wiederbeschaffungspreis als für eine Elektrode mit Fixkabel; Einfache Aufbewahrung: Die Elektrode kann leicht zwischen Messserien aufbewahrt werden. Es ist kein Kabel im Weg, da dieses getrennt gelagert werden / am Gerät bleiben kann.; Schneller Elektrodenwechsel / Einfache Montage auch in automatisierten Systemen: Das Kabel bleibt im Titrationssystem fix installiert, es muss lediglich der Sensor am Titrationskopf gewechselt werden.; Metrohm‘s Beitrag zum Umweltschutz: Reduzierung von Kabelabfällen; Zuverlässigkeit: Der einzigartige Mehrpolstecker für Laborelektroden bietet eine hohe Signalsichersheit durch vergoldete Kontakte.;
- language
- de
- documentpath
- /content/metrohm/shared/de/products/8/1095/81095001
-
en
- title
- Brochure: 6.0258.600 Unitrode with plug-in head U
- description
- The proven Unitrode with Pt 1000 temperature sensor now also comes with a removable electrode cable. The advantages at a glance:Cost advantage: Lower replacement cost than for an electrode with fixed cable.; Simple storage: The electrode is easy to store between measurement series. There is no cable in the way, as it can be stored separately or remains on the instrument.; Faster electrode changing - easy to assemble even in automated systems: The cable remains permanently installed in the titration system; only the sensor on the titration head has to be changed.; Metrohm‘s contribution to environmental protection: Reduction in cable waste.; Reliability: Thanks to gold-plated contacts, the unique multi-pin connector for lab electrodes offers a high level of signal reliability.;
- language
- en
- documentpath
- /content/metrohm/shared/en/products/8/1095/81095001
-
vi
- title
- Brochure: 6.0258.600 Unitrode with plug-in head U
- description
- The proven Unitrode with Pt 1000 temperature sensor now also comes with a removable electrode cable. The advantages at a glance:Cost advantage: Lower replacement cost than for an electrode with fixed cable.; Simple storage: The electrode is easy to store between measurement series. There is no cable in the way, as it can be stored separately or remains on the instrument.; Faster electrode changing - easy to assemble even in automated systems: The cable remains permanently installed in the titration system; only the sensor on the titration head has to be changed.; Metrohm‘s contribution to environmental protection: Reduction in cable waste.; Reliability: Thanks to gold-plated contacts, the unique multi-pin connector for lab electrodes offers a high level of signal reliability.;
- language
- vi
- documentpath
- /content/metrohm/shared/vi/products/8/1095/81095001
-
de
-
81098063
-
de
- title
- Merkblatt pH-Glas- und Gelelektroden
- description
- language
- de
- documentpath
- /content/metrohm/shared/de/products/8/1098/81098063
-
en
- title
- Leaflet pH glass and gel electrodes
- description
- language
- en
- documentpath
- /content/metrohm/shared/en/products/8/1098/81098063
-
fr
- title
- Feuille de renseignement électrodes de pH de verre et gel
- description
- language
- fr
- documentpath
- /content/metrohm/shared/fr/products/8/1098/81098063
-
ja
- title
- リーフレット pH glass and gel electrodes
- description
- language
- ja
- documentpath
- /content/metrohm/shared/ja/products/8/1098/81098063
-
es
- title
- Folleto de electrodos de vidrio y gel de pH
- description
- language
- es
- documentpath
- /content/metrohm/shared/es/products/8/1098/81098063
-
zh
- title
- pH 玻璃和凝胶电极说明书
- description
- language
- zh
- documentpath
- /content/metrohm/shared/zh/products/8/1098/81098063
-
pt
- title
- Eletrodos de vidro e de gel de pH
- description
- language
- pt
- documentpath
- /content/metrohm/shared/pt/products/8/1098/81098063
-
vi
- title
- Leaflet pH glass and gel electrodes
- description
- language
- vi
- documentpath
- /content/metrohm/shared/vi/products/8/1098/81098063
-
ko
- title
- pH 유리 전극 및 겔 전극
- description
- language
- ko
- documentpath
- /content/metrohm/shared/ko/products/8/1098/81098063
-
de
-
- Sleeve with SGJ 14/12 mm
- 6.1236.050
- Sleeve with SGJ 14/12 mm, polyethylene.
- Sleeve with SGJ 14/12 mm, polyethylene.
- PCS
- 1
- Storage vessel
- 6.2008.040
- Together with 6.2008.050 storage vessel holder. it provides a support for the electrode on 807 Dosing Units.
- <p>Together with 6.2008.050 storage vessel holder. it provides a support for the electrode on 807 Dosing Units.</p>
- PCS
- 1
-
- Sleeve with SGJ 14/12 mm
- 6.1236.050
- Sleeve with SGJ 14/12 mm, polyethylene.
- Sleeve with SGJ 14/12 mm, polyethylene.
- PCS
- 1
- Storage vessel
- 6.2008.040
- Together with 6.2008.050 storage vessel holder. it provides a support for the electrode on 807 Dosing Units.
- <p>Together with 6.2008.050 storage vessel holder. it provides a support for the electrode on 807 Dosing Units.</p>
- PCS
- 1
-
- Electrode cable for plug in head U/plug F, 2x2 mm B, 1m
- 6.2104.600
- For connecting electrodes with Metrohm plug-in head U to Metrohm instruments (socket F).
- For connecting electrodes with Metrohm plug-in head U to Metrohm instruments (socket F).
- PCS
- 1
- Electrode cable for plug in head U/plug F, 2x2 mm B, 2m
- 6.2104.610
- For connecting electrodes with Metrohm plug-in head U to Metrohm instruments (socket F).
- For connecting electrodes with Metrohm plug-in head U to Metrohm instruments (socket F).
- PCS
- 1
- Electrolyte 3 mol/L KCl (250 mL)
- 6.2308.020
- Electrolyte solution c(KCl) = 3 mol/L, (for Ag/AgCl reference systems)
- Electrolyte solution c(KCl) = 3 mol/L, (for Ag/AgCl reference systems)
- PCS
- 1
- Idrolyte (250 mL)
- 6.2308.040
- Idrolyte (for 6.0224.100 Electrode and Unitrode at T >80°C)
- Idrolyte (for 6.0224.100 Electrode and Unitrode at T >80°C)
- PCS
- 1
- Storage solution
- 6.2323.000
- Storage solution for all combined pH glass electrodes with reference electrolyte c(KCl) = 3 mol/L
- Storage solution for all combined pH glass electrodes with reference electrolyte c(KCl) = 3 mol/L
- PCS
- 1
- pHit kit
- 6.2325.000
- Maintenance kit for pH electrodes The kit contains:50 mL cleaning solution; 50 mL 3M KCl solution; 50 mL storage solution; 2 Storage vessels; Instructions for use;
- <p>Maintenance kit for pH electrodes </p><p>The kit contains:</p><ul><li>50 mL cleaning solution</li><li>50 mL 3M KCl solution</li><li>50 mL storage solution</li><li>2 Storage vessels</li><li>Instructions for use</li></ul>
- PCS
- 1
- Cleaning solution 3 x 50 mL
- 6.2325.100
- Reliable measuring results over long periods of time can be guaranteed only if the pH glass membrane and the diaphragm receive preventive and regular care. Cleaning by etching with toxic chemicals or applying mechanical treatment to the diaphragm is not only complicated and expensive, it also accelerates the ageing of the pH glass electrode.The cleaning solution was developed for easy and gentle cleaning of pH glass electrodes. Regular use can considerably prolong their service life.This cleaning solution is also part of the pHit kit.
- <p>Reliable measuring results over long periods of time can be guaranteed only if the pH glass membrane and the diaphragm receive preventive and regular care. Cleaning by etching with toxic chemicals or applying mechanical treatment to the diaphragm is not only complicated and expensive, it also accelerates the ageing of the pH glass electrode.<br />The cleaning solution was developed for easy and gentle cleaning of pH glass electrodes. Regular use can considerably prolong their service life.<br /><br />This cleaning solution is also part of the pHit kit.</p>
- PCS
- 1