Metrosep C 3 - 150/4.0
6.1010.420
Metrosep C 3 - 150/4.0
en
6.1010.420
Feature overview
The innovative substrate on a polyvinyl alcohol base increases selectivity for monovalent and divalent cations significantly. The peak forms on this cation column are highly symmetrical.
The middle separation column of the Metrosep-C-3 product range is particularly suitable for rapid separations of standard cations and certain transition metal cations as well as for separating mid-sized organic amines.
Tech specs
| ApplicationRange | Applications
|
|---|---|
| Organic Modifier | 0 - 50% acetonitrile, |
| Regeneration | Add 30% acetonitrile to the standard eluent |
| StandardEluent | Nitric acid eluent (standard eluent) Nitric acid (c = 1 mol/L): 5.0 mmol/L; 10 mL/2 L Nitric acid (c = 1 mol/L): 2.5 mmol/L; 5 mL/2 L |
| Storage | For 1 - 3 days in the eluent; in ultrapure water for longer storage. Recommended temperature: 4 - 8 °C. |
| Capacity | 18 µmol (K+) |
| Housing material | PEEK |
| Carrier material | Polyvinyl alcohol with carboxyl groups |
| Particle size | 5 µm |
| Standard flow | 1.0 mL/min |
| Maximum pressure | 15 MPa |
| Maximum flow | 1.5 mL/min |
| pH range | 2–12 |
| Column dimensions | 150 x 4.0 mm |
| Temperature range | 20–40 °C |
Chromatogram
-
- Metrosep C 3 Guard/4.0
- 6.1010.450
- The Metrosep C 3 S-Guard/4.0 contains the C-3 column material and is used to protect Metrosep C-3 cation columns. Particles and contamination are reliably retained, considerably prolonging the service life of the analytical separation column. The Metrosep C 3 Guard/4.0 also works based on the "On Column Guard System" and is screwed directly onto the separation column with virtually no dead volume.
- <p>The Metrosep C 3 S-Guard/4.0 contains the C-3 column material and is used to protect Metrosep C-3 cation columns. Particles and contamination are reliably retained, considerably prolonging the service life of the analytical separation column. The Metrosep C 3 Guard/4.0 also works based on the "On Column Guard System" and is screwed directly onto the separation column with virtually no dead volume.</p>
- PCS
- 1
- Metrosep C 3 S-Guard/4.0
- 6.1010.460
- The Metrosep C 3 S-Guard/4.0 contains the C-3 column material and is used to protect Metrosep C-3 cation columns. Particles and contamination are reliably retained, considerably prolonging the service life of the analytical separation column.
- <p>The Metrosep C 3 S-Guard/4.0 contains the C-3 column material and is used to protect Metrosep C-3 cation columns. Particles and contamination are reliably retained, considerably prolonging the service life of the analytical separation column.</p>
- PCS
- 1