You have been redirected to your local version of the requested page
Combined polymer membrane electrode, NO3

Combined polymer membrane electrode, NO3

6.00510.120

Combined polymer membrane electrode, NO3

en

6.00510.120

Feature overview

Combined nitrate-selective electrode with polymer membrane.
This ISE is suitable for:
 

  • ion measurements of NO3- (7*10-6 to 1 mol/L) in aqueous solutions
  • titrations in aqueous solutions


Thanks to a robust/break-proof plastic shaft made of propylene and an impact protection for the polymer membrane, this sensor is mechanically very resistant.
The reference electrolyte used is c(KCl) = 3 mol/L.

Tech specs

SGJ sleeveflexible
Resistance (kOhm)<10
Shaft materialPMMA/PP
Measuring range (theoretical)1x10E-6...1
Measuring unitmol/L
Temperature range, long-term (°C)0...40
Temperature range, short-term (°C)0...40
pH range2.5...11
Max. installation length (mm)113
Shaft diameter top (mm)12
Shaft diameter bottom (mm)12
Min. immersion depth (mm)10
Electrode plug-in headMetrohm plug-in head G
Indicator electrode typePolymer (NO3)
DiaphragmCeramic pin
Reference electrolyte typec(KCl) = 3 mol/L
Reference systemAg/AgCl/3M KCl
Membrane materialPolymer
IonNO3-
Indicator electrode shapeFlat
This field is required.
    • Sleeve with SGJ 14/12 mm
    • 6.1236.050
    • Sleeve with SGJ 14/12 mm, polyethylene.
    • Sleeve with SGJ 14/12 mm, polyethylene.
    • Stk
    • 100
    • Storage vessel 
    • 6.2008.040
    • Together with 6.2008.050 storage vessel holder. it provides a support for the electrode on 807 Dosing Units.
    • <p>Together with 6.2008.050 storage vessel holder. it provides a support for the electrode on 807 Dosing Units.</p>
    • Stk
    • 100
    • Sleeve with SGJ 14/12 mm
    • 6.1236.050
    • Sleeve with SGJ 14/12 mm, polyethylene.
    • Sleeve with SGJ 14/12 mm, polyethylene.
    • Stk
    • 100
    • Storage vessel 
    • 6.2008.040
    • Together with 6.2008.050 storage vessel holder. it provides a support for the electrode on 807 Dosing Units.
    • <p>Together with 6.2008.050 storage vessel holder. it provides a support for the electrode on 807 Dosing Units.</p>
    • Stk
    • 100
    • Electrolyte 3 mol/L KCl (250 mL)
    • 6.2308.020
    • Electrolyte solution c(KCl) = 3 mol/L, (for Ag/AgCl reference systems)
    • Electrolyte solution c(KCl) &#61; 3 mol/L, (for Ag/AgCl reference systems)
    • PCS
    • 1
    • Electrolyte 3 mol/L KCl (50 mL)
    • 6.2308.050
    • Electrolyte solution c(KCl) = 3 mol/L (for Ag/AgCl reference systems)
    • Electrolyte solution c(KCl) &#61; 3 mol/L (for Ag/AgCl reference systems)
    • PCS
    • 1
    • Electrode cable / 1 m / F
    • 6.2104.020
    • For connecting electrodes with Metrohm plug-in head G to Metrohm instruments (socket F).
    • For connecting electrodes with Metrohm plug-in head G to Metrohm instruments (socket F).
    • PCS
    • 1