You have been redirected to your local version of the requested page
867 pH Module with Touch Control

867 pH Module with Touch Control

2.867.0110

    • iUnitrode with Pt1000
    • 6.0278.300
    • Intelligent, combined pH electrode with integrated memory chip for storing sensor data and Pt1000 temperature sensor. This electrode is particularly suitable:for pH measurements and titrations in difficult, viscous, or alkaline samples; at elevated temperatures; for long-term measurements; The fixed ground-joint diaphragm is insensitive to contamination.Reference electrolyte: c(KCl) = 3 mol/L, storage in storage solution.Alternatively: reference electrolyte for measurements at T>80°C: Idrolyte, storage in Idrolyte.iTrodes can be connected to Titrando, Ti-Touch or 913/914 meters.
    • <p>Intelligent, combined pH electrode with integrated memory chip for storing sensor data and Pt1000 temperature sensor. This electrode is particularly suitable:</p><ul><li>for pH measurements and titrations in difficult, viscous, or alkaline samples</li><li>at elevated temperatures</li><li>for long-term measurements</li></ul><p>The fixed ground-joint diaphragm is insensitive to contamination.<br/><br/>Reference electrolyte: c(KCl) = 3 mol/L, storage in storage solution.<br/>Alternatively: reference electrolyte for measurements at T&gt;80°C: Idrolyte, storage in Idrolyte.<br/>iTrodes can be connected to Titrando, Ti-Touch or 913/914 meters.</p>
    • PCS
    • 1
    • Support stand without support rod
    • 6.2001.060
    • To attach an 801, 804, 803 Stirrer to a Titrando, Titrino plus, Dosimat plus or 856 and 867.
    • To attach an 801, 804, 803 Stirrer to a Titrando, Titrino plus, Dosimat plus or 856 and 867.
    • PCS
    • 1
    • Clamping ring
    • 6.2013.010
    • For support rods with a diameter of 10 mm.
    • <p>For support rods with a diameter of 10 mm.</p>
    • PCS
    • 1
    • Electrode holder
    • 6.2021.020
    • Electrode holder for 4 electrodes and 2 buret tips
    • Electrode holder for 4 electrodes and 2 buret tips
    • PCS
    • 1
    • Buffer solutions pH 4, 7 and 9
    • 6.2307.230
    • Mixed buffer solutions pH 4.00/7.00/9.00 (25 °C) in single use sachets, colourless, box of 3 x 10 x 30 mL
    • Mixed buffer solutions pH 4.00/7.00/9.00 (25 °C) in single use sachets, colourless, box of 3 x 10 x 30 mL
    • PCS
    • 1
    • pHit kit
    • 6.2325.000
    • Maintenance kit for pH electrodes The kit contains:50 mL cleaning solution; 50 mL 3M KCl solution; 50 mL storage solution; 2 Storage vessels; Instructions for use;
    • <p>Maintenance kit for pH electrodes </p><p>The kit contains:</p><ul><li>50 mL cleaning solution</li><li>50 mL&nbsp;3M KCl solution</li><li>50 mL&nbsp;storage solution</li><li>2 Storage vessels</li><li>Instructions for use</li></ul>
    • PCS
    • 1
    • 854 iConnect
    • 1.854.0010
    • 854 iConnect - electrode cable and measuring amplifier for intelligent electrodes «iTrodes».
    • <p>854 iConnect - electrode cable and measuring amplifier for intelligent electrodes &laquo;iTrodes&raquo;.</p>
    • PCS
    • 1
    • 867 pH Module
    • 1.867.0010
    • Module for pH/ion measurement as supplement to a Titrando or "stand-alone" in combination with a 900 Touch Control.In addition to measurements of pH, temperature, mV, Ipol, Upol and concentration, the pH Module can perform standard additions (manual, dos, autodos) and Liquid Handling (add, prep, empty). It enables the use of both conventional and intelligent sensors for measuring. Also integrated in the software is an automatic GLP-compliant pH electrode test.The pH Module has two USB interfaces for connecting printers, barcode readers or sample changers and four MSB interfaces for stirrers or Dosinos (for the addition of auxiliary solutions or for standard addition).Both in conjunction with the Touch Control and also integrated in tiamo™ full (from 2.0), it is in compliance with GLP and FDA 21 CFR part 11 requirements.
    • <p><strong>Module for pH/ion measurement as supplement to a Titrando or "stand-alone" in combination with a 900 Touch Control.</strong></p><p>In addition to measurements of pH, temperature, mV, Ipol, Upol and concentration, the pH Module can perform standard additions (manual, dos, autodos) and Liquid Handling (add, prep, empty). It enables the use of both conventional and intelligent sensors for measuring. Also integrated in the software is an automatic GLP-compliant pH electrode test.<br/><br/>The pH Module has two USB interfaces for connecting printers, barcode readers or sample changers and four MSB interfaces for stirrers or Dosinos (for the addition of auxiliary solutions or for standard addition).<br/>Both in conjunction with the Touch Control and also integrated in <em><strong>tiamo</strong></em>™ full (from 2.0), it is in compliance with GLP and FDA 21 CFR part 11 requirements.</p>
    • PCS
    • 1
    • 900 Touch Control
    • 1.900.0010
    • Operating unit for the Titrandos, USB Sample Processors, 856 Conductivity Module, 867 pH Module and 846 Dosing Interface. Touch-sensitive, high-resolution color display, simple and intuitive operation, thanks to Favorites for direct method access. With integrated Ethernet interface for direct connection to the Internet and USB interface for connecting USB printers or a USB memory stick.Dialog languages: German, English, Chinese, French, Spanish, Portuguese, Russian, Korean, Polish and Italian. 
    • <p>Operating unit for the Titrandos, USB Sample Processors, 856 Conductivity Module, 867 pH Module and 846 Dosing Interface. Touch-sensitive, high-resolution color display, simple and intuitive operation, thanks to Favorites for direct method access. With integrated Ethernet interface for direct connection to the Internet and USB interface for connecting USB printers or a USB memory stick.</p><p>Dialog languages: German, English, Chinese, French, Spanish, Portuguese, Russian, Korean, Polish and Italian.<br/> </p>
    • PCS
    • 1
    • iUnitrode with Pt1000
    • 6.0278.300
    • Intelligent, combined pH electrode with integrated memory chip for storing sensor data and Pt1000 temperature sensor. This electrode is particularly suitable:for pH measurements and titrations in difficult, viscous, or alkaline samples; at elevated temperatures; for long-term measurements; The fixed ground-joint diaphragm is insensitive to contamination.Reference electrolyte: c(KCl) = 3 mol/L, storage in storage solution.Alternatively: reference electrolyte for measurements at T>80°C: Idrolyte, storage in Idrolyte.iTrodes can be connected to Titrando, Ti-Touch or 913/914 meters.
    • <p>Intelligent, combined pH electrode with integrated memory chip for storing sensor data and Pt1000 temperature sensor. This electrode is particularly suitable:</p><ul><li>for pH measurements and titrations in difficult, viscous, or alkaline samples</li><li>at elevated temperatures</li><li>for long-term measurements</li></ul><p>The fixed ground-joint diaphragm is insensitive to contamination.<br/><br/>Reference electrolyte: c(KCl) = 3 mol/L, storage in storage solution.<br/>Alternatively: reference electrolyte for measurements at T&gt;80°C: Idrolyte, storage in Idrolyte.<br/>iTrodes can be connected to Titrando, Ti-Touch or 913/914 meters.</p>
    • PCS
    • 1
    • Support stand without support rod
    • 6.2001.060
    • To attach an 801, 804, 803 Stirrer to a Titrando, Titrino plus, Dosimat plus or 856 and 867.
    • To attach an 801, 804, 803 Stirrer to a Titrando, Titrino plus, Dosimat plus or 856 and 867.
    • PCS
    • 1
    • Clamping ring
    • 6.2013.010
    • For support rods with a diameter of 10 mm.
    • <p>For support rods with a diameter of 10 mm.</p>
    • PCS
    • 1
    • Electrode holder
    • 6.2021.020
    • Electrode holder for 4 electrodes and 2 buret tips
    • Electrode holder for 4 electrodes and 2 buret tips
    • PCS
    • 1
    • Buffer solutions pH 4, 7 and 9
    • 6.2307.230
    • Mixed buffer solutions pH 4.00/7.00/9.00 (25 °C) in single use sachets, colourless, box of 3 x 10 x 30 mL
    • Mixed buffer solutions pH 4.00/7.00/9.00 (25 °C) in single use sachets, colourless, box of 3 x 10 x 30 mL
    • PCS
    • 1
    • pHit kit
    • 6.2325.000
    • Maintenance kit for pH electrodes The kit contains:50 mL cleaning solution; 50 mL 3M KCl solution; 50 mL storage solution; 2 Storage vessels; Instructions for use;
    • <p>Maintenance kit for pH electrodes </p><p>The kit contains:</p><ul><li>50 mL cleaning solution</li><li>50 mL&nbsp;3M KCl solution</li><li>50 mL&nbsp;storage solution</li><li>2 Storage vessels</li><li>Instructions for use</li></ul>
    • PCS
    • 1
    • 801 Stirrer
    • 2.801.0010
    • Magnetic stirrer without stand for supplementing the Titrino plus, Dosimat plus, Titrandos, Sample Processors, 805 Dosimats and 780/781 pH Meters. With permanently attached cable for MSB (Metrohm Serial Bus).
    • <p>Magnetic stirrer without stand for supplementing the Titrino plus, Dosimat plus, Titrandos, Sample Processors, 805 Dosimats and 780/781 pH Meters. With permanently attached cable for MSB (Metrohm Serial Bus).</p>
    • PCS
    • 1
    • 802 Stirrer for 804 Ti Stand
    • 2.802.0040
    • Rod stirrer including 6.1909.010 stirring propeller.
    • Rod stirrer including 6.1909.010 stirring propeller.
    • PCS
    • 1
    • 804 Ti Stand without stand rod
    • 2.804.0010
    • Titration stand and controller for 802 Stirrer. The 804 Ti Stand together with the optional 802 Stirrer provides an alternative to the magnetic stirrer. Without stand.
    • Titration stand and controller for 802 Stirrer. The 804 Ti Stand together with the optional 802 Stirrer provides an alternative to the magnetic stirrer. Without stand.
    • PCS
    • 1
    • 814 USB Sample Processor (1T/1P)
    • 2.814.0010
    • USB Sample Processor with one workstation and one built-in membrane pump for the automatic processing of routine samples in series with small to medium quantities. In addition to the built-in pump, an additional one (membrane or peristaltic) and up to three dosing devices for Liquid Handling tasks can be connected.Because of the multitude of application variants, rack, stirrer, titration head, Swing Head and sample vessels must be tailored to the application and ordered separately.The control is "stand alone" using Touch Control. The following software products can be selected for the PC control: tiamo™ titration software, MagIC Net chromatography software, viva voltammetry software, or OMNIS.
    • <p>USB Sample Processor with one workstation and one built-in membrane pump for the automatic processing of routine samples in series with small to medium quantities. In addition to the built-in pump, an additional one (membrane or peristaltic) and up to three dosing devices for Liquid Handling tasks can be connected.<br/> <br/>Because of the multitude of application variants, rack, stirrer, titration head, Swing Head and sample vessels must be tailored to the application and ordered separately.</p><p>The control is "stand alone" using Touch Control. The following software products can be selected for the PC control: tiamo™ titration software, MagIC Net chromatography software, viva voltammetry software, or OMNIS.</p>
    • PCS
    • 1
    • 814 USB Sample Processor (1T/2P)
    • 2.814.0020
    • USB Sample Processor with one workstation and two built-in membrane pumps for the automatic processing of routine samples in series with small to medium quantities. In addition to the built-in pumps, up to three dosing devices for Liquid Handling tasks can be connected.Because of the multitude of application variants, rack, stirrer, titration head, Swing Head and sample vessels must be tailored to the application and ordered separately. The control is "stand alone" using Touch Control. The following software products can be selected for the PC control: tiamo™ titration software, MagIC Net chromatography software, viva voltammetry software, or OMNIS.
    • <p>USB Sample Processor with one workstation and two built-in membrane pumps for the automatic processing of routine samples in series with small to medium quantities. In addition to the built-in pumps, up to three dosing devices for Liquid Handling tasks can be connected.<br/> <br/>Because of the multitude of application variants, rack, stirrer, titration head, Swing Head and sample vessels must be tailored to the application and ordered separately.<br/> </p><p>The control is "stand alone" using Touch Control. The following software products can be selected for the PC control: tiamo™ titration software, MagIC Net chromatography software, viva voltammetry software, or OMNIS.</p>
    • PCS
    • 1
    • 814 USB Sample Processor (1T/0P)
    • 2.814.0030
    • USB Sample Processor with one workstation for the automatic processing of routine samples in series with small to medium quantities. Up to two pumps (membrane or peristaltic) and three dosing devices for Liquid Handling tasks can be connected.Because of the multitude of application variants, rack, stirrer, titration head, Swing Head and sample vessels must be tailored to the application and ordered separately.The control is "stand alone" using Touch Control. The following software products can be selected for the PC control: tiamo™ titration software, MagIC Net chromatography software, viva voltammetry software, or OMNIS. 
    • <p>USB Sample Processor with one workstation for the automatic processing of routine samples in series with small to medium quantities. Up to two pumps (membrane or peristaltic) and three dosing devices for Liquid Handling tasks can be connected.<br/> <br/>Because of the multitude of application variants, rack, stirrer, titration head, Swing Head and sample vessels must be tailored to the application and ordered separately.</p><p>The control is "stand alone" using Touch Control. The following software products can be selected for the PC control: tiamo™ titration software, MagIC Net chromatography software, viva voltammetry software, or OMNIS.<br/> </p>
    • PCS
    • 1
Contact

Metrohm Vietnam Co., LTD

Park IX Building 08 Phan Dinh Giot Street, Ward Tan Son Hoa, Tan Binh District
700000 Ho Chi Minh City

Contact