819 Advanced IC Detector (PEEK)
2.819.0110
819 Advanced IC Detector (PEEK)
en
2.819.0110
Feature overview
Top-class conductivity detector for measurements with and without chemical suppression. Temperature-stability better than< 0.01 °C. Shielded by Faraday cage. Wet part and electronics clearly separated. Electronic suppression. PEEK version.
Tech specs
| Dimensions in mm (W/H/D) | 255/130/343 |
|---|
High-performance conductivity detector
- Detector block temperature 25...45 °C in 5 °C steps
- Temperature stability <0.01 °C
- Cell constant calibrated, can be set from 13...21 cm-1
- Cell volume 0.8 µL (nominal)
- Measuring ranges 7 ranges from 0...100 µS/cm to 0...10 000 µS/cm
- Full-scale ranges 11 steps from 0.05...100% of the measuring range
- Measured value output 0...1 V analog
- Auto zero yes, manual or triggered externally
- Remote lines 8 I/O for TTL or relays
This product has been discontinued, but is still supported.
-
- RS-232 cable 1 m, 25-pin D – sub 25
- 6.2125.090
- RS-232 extension cable (1:1). Specially shielded.
- RS-232 extension cable (1:1). Specially shielded.
- PCS
- 1
- RS-232 cable 3 m, 25-pin – 9-pin
- 6.2125.110
- Connecting Metrohm RS-232 interface to PC. Used with pH Meters, Titrinos, KF Coulometers, VA Trace Analyzer.
- Connecting Metrohm RS-232 interface to PC. Used with pH Meters, Titrinos, KF Coulometers, VA Trace Analyzer.
- PCS
- 1
- Magnetic shield for instrument identification
- 6.2248.000
- For IC Instruments
- For IC Instruments
- PCS
- 1
-
- 732 IC Detector
- 1.732.0110
- Top-class conductivity detector for measurements with and without chemical suppression. Temperature-stability better than< 0.01 °C. Shielded by Faraday cage. Wet part and electronics clearly separated. Electronic suppression. PEEK version.
- Top-class conductivity detector for measurements with and without chemical suppression. Temperature-stability better than< 0.01 °C. Shielded by Faraday cage. Wet part and electronics clearly separated. Electronic suppression. PEEK version.
- PCS
- 1
- 819 Advanced IC Detector (metal)
- 1.819.0010
- Top-class conductivity detector for measurements with and without chemical suppression. Temperature-stability better than< 0.01 °C. Shielded by Faraday cage. Wet part and electronics clearly separated. Electronic suppression. Stainless steel version.
- Top-class conductivity detector for measurements with and without chemical suppression. Temperature-stability better than< 0.01 °C. Shielded by Faraday cage. Wet part and electronics clearly separated. Electronic suppression. Stainless steel version.
- PCS
- 1
- RS-232 cable 1 m, 25-pin D – sub 25
- 6.2125.090
- RS-232 extension cable (1:1). Specially shielded.
- RS-232 extension cable (1:1). Specially shielded.
- PCS
- 1
- RS-232 cable 3 m, 25-pin – 9-pin
- 6.2125.110
- Connecting Metrohm RS-232 interface to PC. Used with pH Meters, Titrinos, KF Coulometers, VA Trace Analyzer.
- Connecting Metrohm RS-232 interface to PC. Used with pH Meters, Titrinos, KF Coulometers, VA Trace Analyzer.
- PCS
- 1
- Magnetic shield for instrument identification
- 6.2248.000
- For IC Instruments
- For IC Instruments
- PCS
- 1
-
- Cable 771 (analog) - 819
- 6.2134.140
- Connection of analog and start signals to 771
- Connection of analog and start signals to 771
- PCS
- 1