You have been redirected to your local version of the requested page
819 Advanced IC Detector (PEEK)

819 Advanced IC Detector (PEEK)

2.819.0110

819 Advanced IC Detector (PEEK)

en

2.819.0110

Feature overview

Top-class conductivity detector for measurements with and without chemical suppression. Temperature-stability better than< 0.01 °C. Shielded by Faraday cage. Wet part and electronics clearly separated. Electronic suppression. PEEK version.

Tech specs

Dimensions in mm (W/H/D)255/130/343

High-performance conductivity detector

  • Detector block temperature 25...45 °C in 5 °C steps
  • Temperature stability <0.01 °C
  • Cell constant calibrated, can be set from 13...21 cm-1
  • Cell volume 0.8 µL (nominal)
  • Measuring ranges 7 ranges from 0...100 µS/cm to 0...10 000 µS/cm
  • Full-scale ranges 11 steps from 0.05...100% of the measuring range
  • Measured value output 0...1 V analog
  • Auto zero yes, manual or triggered externally
  • Remote lines 8 I/O for TTL or relays
This product has been discontinued, but is still supported.
    • RS-232 cable 3 m, 25-pin – 9-pin
    • 6.2125.110
    • Connecting Metrohm RS-232 interface to PC. Used with pH Meters, Titrinos, KF Coulometers, VA Trace Analyzer.
    • Connecting Metrohm RS-232 interface to PC. Used with pH Meters, Titrinos, KF Coulometers, VA Trace Analyzer.
    • PCS
    • 1
    • 732 IC Detector
    • 1.732.0110
    • Top-class conductivity detector for measurements with and without chemical suppression. Temperature-stability better than< 0.01 °C. Shielded by Faraday cage. Wet part and electronics clearly separated. Electronic suppression. PEEK version.
    • Top-class conductivity detector for measurements with and without chemical suppression. Temperature-stability better than&lt; 0.01 °C. Shielded by Faraday cage. Wet part and electronics clearly separated. Electronic suppression. PEEK version.
    • PCS
    • 1
    • 819 Advanced IC Detector (metal)
    • 1.819.0010
    • Top-class conductivity detector for measurements with and without chemical suppression. Temperature-stability better than< 0.01 °C. Shielded by Faraday cage. Wet part and electronics clearly separated. Electronic suppression. Stainless steel version.
    • Top-class conductivity detector for measurements with and without chemical suppression. Temperature-stability better than&lt; 0.01 °C. Shielded by Faraday cage. Wet part and electronics clearly separated. Electronic suppression. Stainless steel version.
    • PCS
    • 1
    • RS-232 cable 3 m, 25-pin – 9-pin
    • 6.2125.110
    • Connecting Metrohm RS-232 interface to PC. Used with pH Meters, Titrinos, KF Coulometers, VA Trace Analyzer.
    • Connecting Metrohm RS-232 interface to PC. Used with pH Meters, Titrinos, KF Coulometers, VA Trace Analyzer.
    • PCS
    • 1
    • Cable 771 (analog) - 819
    • 6.2134.140
    • Connection of analog and start signals to 771
    • Connection of analog and start signals to 771
    • PCS
    • 1