You have been redirected to your local version of the requested page
889 IC Sample Center Basic - cool

889 IC Sample Center Basic - cool

2.889.0040

889 IC Sample Center Basic - cool

en

2.889.0040

Feature overview

The 889 IC Sample Center Basic – cool is the appropriate automation solution when you have only a very small amount of sample. In comparison with the 889 IC Sample Center Basic, it possesses in addition a cooling function and is thus the ideal sample changer for biochemically relevant or thermally unstable samples.

The sample transfer takes place either with a peristaltic pump in the IC system or with an 800 Dosino, e.g. when applying the intelligent Partial Loop Injection Technique.

Supported with MagIC Net 4.1 and higher.

Product Family

title
Automation for IC
description
Whatever the number of samples and whatever preparatory treatment, we provide automated solutions for ion chromatography to meet your requirements.

Documents

    • Sample rack, 48 x 11 mL, (Al)
    • 6.2041.200
    • Sample rack for 889 IC Sample Center, suitable for 48 sample vessels. The following sample vessels can be used: 6.2743.100, 6.2743.107, 6.2743.110, 6.2743.117.Material: Aluminum (Al)
    • <p>Sample rack for 889 IC Sample Center, suitable for 48 sample vessels. The following sample vessels can be used: 6.2743.100, 6.2743.107, 6.2743.110, 6.2743.117.<br /><br />Material: Aluminum (Al)</p>
    • PCS
    • 2
    • Pressure screw 5x
    • 6.2744.010
    • With UNF 10/32 connection. For the connection of PEEK capillaries
    • With UNF 10/32 connection. For the connection of PEEK capillaries
    • PCS
    • 1
    • Sample rack, 48 x 11 mL, (Al)
    • 6.2041.200
    • Sample rack for 889 IC Sample Center, suitable for 48 sample vessels. The following sample vessels can be used: 6.2743.100, 6.2743.107, 6.2743.110, 6.2743.117.Material: Aluminum (Al)
    • <p>Sample rack for 889 IC Sample Center, suitable for 48 sample vessels. The following sample vessels can be used: 6.2743.100, 6.2743.107, 6.2743.110, 6.2743.117.<br /><br />Material: Aluminum (Al)</p>
    • PCS
    • 2
    • Pressure screw 5x
    • 6.2744.010
    • With UNF 10/32 connection. For the connection of PEEK capillaries
    • With UNF 10/32 connection. For the connection of PEEK capillaries
    • PCS
    • 1
    • Screw cap with septum, 100 pcs.
    • 6.1448.067
    • Screw cap with septum, suitable for sample glass 8 mL 6.2420.007, 100 pieces 
    • <p>Screw cap with septum, suitable for sample glass 8 mL 6.2420.007, 100 pieces<br /> </p>
    • PCS
    • 1
    • Sample rack, 12 x 6 mL, (Al)
    • 6.2041.210
    • Sample rack for 889 IC Sample Center, suitable for 12 sample vessels. The following sample vessels can be used: 6.2419.000.Material: Aluminum (Al)
    • <p>Sample rack for 889 IC Sample Center, suitable for 12 sample vessels. The following sample vessels can be used: 6.2419.000.</p><p>Material: Aluminum (Al)</p>
    • PCS
    • 1
    • Sample glass, 6 mL, 100 pieces
    • 6.2419.007
    • Sample glass for up to 6 mL sample, suitable for 6.1448.057 septum, 100 pieces 
    • <p>Sample glass for up to 6 mL sample, suitable for 6.1448.057 septum, 100 pieces</p><p> </p>
    • PCS
    • 1
    • Sample glass with thread, 8 mL, 100 pieces
    • 6.2420.007
    • Sample glass with thread, 8 mL, suitable for 6.1448.067 screw cap, 100 pieces 
    • <p>Sample glass with thread, 8 mL, suitable for 6.1448.067 screw cap, 100 pieces<br /> </p>
    • PCS
    • 1
    • Crimping tongs
    • 6.2621.110
    • Crimping tongs for sealing 6 mL sample vials (6.2419.000, 6.2419.007).
    • Crimping tongs for sealing 6 mL sample vials (6.2419.000, 6.2419.007).
    • PCS
    • 1
    • Glass vial, 1.5 mL, 100 pieces
    • 6.7303.100
    • For use with the following sample changers: Liquid Autosampler CIC (TEI), MMS 5000 Autosampler (AJ) and 889 Sample Center.
    • <p>For use with the following sample changers: Liquid Autosampler CIC (TEI), MMS 5000 Autosampler (AJ) and 889 Sample Center.</p>
    • PCS
    • 1
    • Septum for 67303100, 100 pieces
    • 6.7303.110
    • For use with the 67303100 Glass vial on the following sample changers: Liquid Autosampler CIC (TEI), MMS 5000 Autosampler (AJ), and 889 Sample Center.
    • <p>For use with the 67303100 Glass vial on the following sample changers: Liquid Autosampler CIC (TEI), MMS 5000 Autosampler (AJ), and 889 Sample Center.</p>
    • PCS
    • 1
    • IC equipment: Full loop, PP, 889 Basic
    • 6.05330.220
    • The IC equipment contains all of the accessory parts necessary for using the peristaltic pump to transfer samples from the 889 IC Sample Center Basic to the ion chromatograph.
    • <p>The IC equipment contains all of the accessory parts necessary for using the peristaltic pump to transfer samples from the 889 IC Sample Center Basic to the ion chromatograph.</p>
    • PCS
    • 1
    • IC equipment: MiPT, 889 Basic
    • 6.05330.230
    • Accessory set for assembling a Dosino for Partial-Loop-Injection in combination with the 889 Basic (28890030 & 28890040)
    • <p>Accessory set for assembling a Dosino for Partial-Loop-Injection in combination with the 889 Basic (28890030 &amp; 28890040)</p>
    • PCS
    • 1