Conductivity measuring cell c = 0.8 cm-1 with Pt1000 (fixed cable)

Conductivity measuring cell c = 0.8 cm-1 with Pt1000 (fixed cable)

6.0912.110

Conductivity measuring cell c = 0.8 cm-1 with Pt1000 (fixed cable)

en

6.0912.110

Visão geral

Conductivity measuring cell with cell constant c = 0.8 cm-1, with integrated Pt1000 temperature sensor and with fixed cable (4 x B (4 mm)). Thanks to the robust/break-proof plastic shaft made of polypropylene and an impact protection, this sensor is mechanically very resistant. This sensor is suitable for measurements of medium conductivities (1 uS/cm to 100 mS/cm), e.g., in:
 

  • drinking water
  • surface water
  • wastewater


The sensor can be connected to an 856 Conductivity Module with the adapter box (6.2103.160).

 

Especificações técnicas

Shaft materialPP
Measuring range (theoretical)1 ... 100'000
Measuring unituS/cm
Temperature range, long-term (°C)5 ... 70
Temperature range, short-term (°C)5 ... 70
Max. installation length (mm)125
SGJ sleeveFlexible SGJ sleeve
Shaft diameter top (mm)12
Shaft diameter bottom (mm)12
Min. immersion depth (mm)35
Electrode plug-in headFixed cable 4xB (4 mm)
Temperature sensorPt1000
TypePt platinized
This field is required.
    • Adapter 4 x socket B – plug N
    • 6.2103.160
    • Adapter box for the connection of classical Metrohm Conductivity measuring cells with 4 banana plugs to the 856 Conductivity Module.
    • Adapter box for the connection of classical Metrohm Conductivity measuring cells with 4 banana plugs to the 856 Conductivity Module.
    • PCS
    • 1
    • KCl ion standard 250 mL
    • 6.2301.060
    • KCl ion standard (c(ion) = 0.1000 +/-0.0005 mol/L), can also be used as standard solution for conductometry 12.87 mS/cm (25 °C).
    • <p>KCl ion standard (c(ion) = 0.1000 +/-0.0005 mol/L), can also be used as standard solution for conductometry 12.87 mS/cm (25 &deg;C).</p>
    • PCS
    • 1
    • Conductivity standard 100 µS/cm 250 mL
    • 6.2324.010
    • Conductivity standard for calibration of conductivity measuring cells with cell constant = 0.1/cm.
    • Conductivity standard for calibration of conductivity measuring cells with cell constant = 0.1/cm.
    • PCS
    • 1
    • Conductivity standard 100 µS/cm, 5 x 30 mL
    • 6.2324.110
    • Conductivity standard for calibration of conductivity measuring cells with cell constant = 0.1/cm.
    • Conductivity standard for calibration of conductivity measuring cells with cell constant = 0.1/cm.
    • PCS
    • 1