6.0502.130

Ion-selective electrode, CN

en

6.0502.130

Visão geral

Cyanide-selective electrode with crystal membrane.
This ISE has to be used in combination with a reference electrode and is suitable for:
 

  • ion measurements of CN- (8*10-6 to 10-2 mol/L)
  • ion measurements in small sample volumes (minimum immersion depth 1 mm)
  • titrations


Thanks to the robust/break-proof plastic shaft made of EP, this sensor is mechanically very resistant.
The polishing set supplied enables easy cleaning and renewing of the electrode surface.

Especificações técnicas

Shaft materialEP
Measuring range (theoretical)8x10-6 ... 10-2
Measuring unitmol/L
Temperature range, long-term (°C)0 ... 80
Temperature range, short-term (°C)0 ... 80
pH range10 ... 14
Indicator electrode shapeFlat
Max. installation length (mm)125
SGJ sleeveFlexible SGJ sleeve
Shaft diameter top (mm)12
Shaft diameter bottom (mm)12
Min. immersion depth (mm)1
Electrode plug-in headMetrohm plug-in head G
Indicator electrode typeCrystal (CN)
This field is required.
    • Polishing set for solid-state electrodes
    • 6.2802.000
    • Polishing set with 1 polishing cloth and about 2 g aluminum oxide powder (grain size 0.3 µm)
    • Polishing set with 1 polishing cloth and about 2 g aluminum oxide powder (grain size 0.3 µm)
    • PCS
    • 1
    • Polishing set for solid-state electrodes
    • 6.2802.000
    • Polishing set with 1 polishing cloth and about 2 g aluminum oxide powder (grain size 0.3 µm)
    • Polishing set with 1 polishing cloth and about 2 g aluminum oxide powder (grain size 0.3 µm)
    • PCS
    • 1
    • LL ISE reference electrode
    • 6.0750.100
    • Silver / silver chloride reference electrode with double junction system.This reference electrode is well suited for:automated applications; ion measurements; surfactant titrations; The ground-joint diaphragm, which is insensitive to contamination, offers a constant and reproducible electrolyte outflow. Additionally, the reference electrolyte is gelified for even better signal stability. The sensor is delivered with c(KCl) = 3 mol/L as bridge electrolyte, which can be freely selected and exchanged as needed.
    • <p>Silver / silver chloride reference electrode with double junction system.<br/>This reference electrode is well suited for:</p><ul><li>automated applications</li><li>ion measurements</li><li>surfactant titrations</li></ul><p>The ground-joint diaphragm, which is insensitive to contamination, offers a constant and reproducible electrolyte outflow. Additionally, the reference electrolyte is gelified for even better signal stability. The sensor is delivered with c(KCl) = 3 mol/L as bridge electrolyte, which can be freely selected and exchanged as needed.</p>
    • PCS
    • 1
    • Electrode cable / 1 m / F
    • 6.2104.020
    • For connecting electrodes with Metrohm plug-in head G to Metrohm instruments (socket F).
    • For connecting electrodes with Metrohm plug-in head G to Metrohm instruments (socket F).
    • PCS
    • 1