Ion-selective electrode, Cl

Ion-selective electrode, Cl

6.0502.120

Ion-selective electrode, Cl

en

6.0502.120

Visão geral

Chloride-selective electrode with crystal membrane.
This ISE has to be used in combination with a reference electrode and is suitable for:
 

  • ion measurements of Cl- (5*10-5 to 1 mol/L)
  • ion measurements in small sample volumes (minimum immersion depth 1 mm)
  • titrations
     

Thanks to the robust/break-proof plastic shaft made of EP, this sensor is mechanically very resistant.
The polishing set supplied enables easy cleaning and renewing of the electrode surface.

Especificações técnicas

SGJ sleeveFlexible SGJ sleeve
Shaft materialEP
Measuring range (theoretical)1x10-5 ... 1
Measuring unitmol/L
Temperature range, long-term (°C)0 ... 50
Temperature range, short-term (°C)0 ... 50
pH range0 ... 14
Max. installation length (mm)125
Shaft diameter top (mm)12
Shaft diameter bottom (mm)12
Min. immersion depth (mm)1
Electrode plug-in headMetrohm plug-in head G
Indicator electrode typeCrystal (Cl)
Indicator electrode shapeFlat
This field is required.
    • Polishing set for solid-state electrodes
    • 6.2802.000
    • Polishing set with 1 polishing cloth and about 2 g aluminum oxide powder (grain size 0.3 µm)
    • Polishing set with 1 polishing cloth and about 2 g aluminum oxide powder (grain size 0.3 µm)
    • Stk
    • 100
    • Polishing set for solid-state electrodes
    • 6.2802.000
    • Polishing set with 1 polishing cloth and about 2 g aluminum oxide powder (grain size 0.3 µm)
    • Polishing set with 1 polishing cloth and about 2 g aluminum oxide powder (grain size 0.3 µm)
    • Stk
    • 100
    • Electrode cable / 1 m / F
    • 6.2104.020
    • For connecting electrodes with Metrohm plug-in head G to Metrohm instruments (socket F).
    • For connecting electrodes with Metrohm plug-in head G to Metrohm instruments (socket F).
    • PCS
    • 1
    • LL ISE reference electrode
    • 6.0750.100
    • Silver / silver chloride reference electrode with double junction system.This reference electrode is well suited for:automated applications; ion measurements; surfactant titrations; The ground-joint diaphragm, which is insensitive to contamination, offers a constant and reproducible electrolyte outflow. Additionally, the reference electrolyte is gelified for even better signal stability. The sensor is delivered with c(KCl) = 3 mol/L as bridge electrolyte, which can be freely selected and exchanged as needed.
    • <p>Silver / silver chloride reference electrode with double junction system.<br />This reference electrode is well suited for:</p><ul><li>automated applications</li><li>ion measurements</li><li>surfactant titrations</li></ul><p>The ground-joint diaphragm, which is insensitive to contamination, offers a constant and reproducible electrolyte outflow. Additionally, the reference electrolyte is gelified for even better signal stability. The sensor is delivered with c(KCl) &#61; 3 mol/L as bridge electrolyte, which can be freely selected and exchanged as needed.</p>
    • PCS
    • 1