dAg ring electrode with Ag2S coating

dAg ring electrode with Ag2S coating

6.00402.300S

dAg ring electrode with Ag2S coating

en

6.00402.300S

Visão geral

Digital, combined silver ring electrode for OMNIS with fixed ground-joint diaphragm. The permanently fused-in silver ring is coated with sulfide (Ag2S) for higher sensitivity and a better limit of detection.
This electrode is suitable for precipitation titrations where the pH value varies (titrant silver nitrate) of, e.g.:

  • Chloride, Bromide, Iodide
  • Sulfides
  • Hydrogen sulfide
  • Mercaptans
  • Cyanides

The fixed ground-joint diaphragm is insensitive to contamination. c(KNO3) = 1 mol/ L is used as reference electrolyte and for storage.
dTrodes can be used on OMNIS Titrators.

Especificações técnicas

Shaft materialGlass
Measuring range (theoretical)-2000...2000
Measuring unitmV
Temperature range, long-term (°C)0...70
Temperature range, short-term (°C)0...70
pH range0...14
Max. installation length (mm)125
SGJ sleeveFlexible ground-joint sleeve
Shaft diameter top (mm)12
Shaft diameter bottom (mm)6
Min. immersion depth (mm)20
Electrode plug-in headMetrohm plug-in head Q
Indicator electrode typeAg
Indicator electrode shapeRing
DiaphragmFixed ground-joint diaphragm
Reference electrolyte typec(KNO3) = 1 mol/L
Electrolyte flow rate (μl/h) at 10 cm water column3...30
Reference systemLL system
Resistance (kOhm)<5
Diaphragm resistance (kOhm)<2
    • Sleeve with SGJ 14/12 mm
    • 6.1236.050
    • Sleeve with SGJ 14/12 mm, polyethylene.
    • Sleeve with SGJ 14/12 mm, polyethylene.
    • PCS
    • 1
    • Storage vessel 
    • 6.2008.040
    • Together with 6.2008.050 storage vessel holder. it provides a support for the electrode on 807 Dosing Units.
    • <p>Together with 6.2008.050 storage vessel holder. it provides a support for the electrode on 807 Dosing Units.</p>
    • PCS
    • 1
    • Sleeve with SGJ 14/12 mm
    • 6.1236.050
    • Sleeve with SGJ 14/12 mm, polyethylene.
    • Sleeve with SGJ 14/12 mm, polyethylene.
    • PCS
    • 1
    • Storage vessel 
    • 6.2008.040
    • Together with 6.2008.050 storage vessel holder. it provides a support for the electrode on 807 Dosing Units.
    • <p>Together with 6.2008.050 storage vessel holder. it provides a support for the electrode on 807 Dosing Units.</p>
    • PCS
    • 1
    • Electrode cable plug-in head Q / plug P, 0.55 m
    • 6.02104.300
    • Cable for connecting a dTrode (plug-in head Q) to the digital measuring module from OMNIS.
    • <p>Cable for connecting a dTrode (plug-in head Q) to the digital measuring module from OMNIS.</p>
    • PCS
    • 1
    • Electrode cable plug-in head Q / plug P, 1.5 m
    • 6.02104.310
    • Cable for connecting a dTrode (plug-in head Q) to the digital measuring module from OMNIS.
    • <p>Cable for connecting a dTrode (plug-in head Q) to the digital measuring module from OMNIS.</p>
    • PCS
    • 1