Você foi redirecionado para a página solicitada
Ag/AgCl reference electrode (length 16.2 cm)

Ag/AgCl reference electrode (length 16.2 cm)

6.0726.110

Ag/AgCl reference electrode (length 16.2 cm)

en

6.0726.110

Visão geral

Silver / silver chloride reference electrode with double junction system, installation length 13.8 cm. This reference electrode is well suited for automated applications. The SGJ 14/15 enables easy assembly and the flexible ground-joint diaphragm, which is insensitive to contamination, can be easily replaced. The reference and bridge electrolyte can be freely selected according to the application and are easy to exchange. This sensor is delivered without electrolyte filling.

Especificações técnicas

Shaft materialGlass
Temperature range, long-term (°C)0 ... 80
Temperature range, short-term (°C)0 ... 80
Max. installation length (mm)138
SGJ sleeveStandard ground-joint 14/15
Shaft diameter top (mm)12
Shaft diameter bottom (mm)8
Min. immersion depth (mm)10
Electrode plug-in headMetrohm socket B
DiaphragmGround-joint diaphragm
Reference electrolyte typevariable
Bridge electrolyte typevariable
Reference systemAg wire/AgCl
Electrolyte outflow (µL/h) with reference to 3 mol/L KCl5...50
Reference resistance (kΩ) with reference to 3 mol/L KClvariable
    • Cable strand, length 0.55 m
    • 6.02105.000
    • Electrode cables (1x banana plug 4 mm, 1x banana plug 2 mm) to connect a disconnected reference electrode to an analog measuring input in an OMNIS titration system.
    • <p>Electrode cables (1x banana plug 4 mm, 1x banana plug 2 mm) to connect a disconnected reference electrode to an analog measuring input in an OMNIS titration system.</p>
    • PCS
    • 1
    • Cable strand, length 1.5 m
    • 6.02105.010
    • Electrode cables (1x banana plug 4 mm, 1x banana plug 2 mm) to connect a disconnected reference electrode to an analog measuring input in an OMNIS titration system, length 1.5 m.
    • <p>Electrode cables (1x banana plug 4 mm, 1x banana plug 2 mm) to connect a disconnected reference electrode to an analog measuring input in an OMNIS titration system, length 1.5 m.</p>
    • PCS
    • 1
    • Diaphragm for reference electrode
    • 6.1243.030
    • Spare ground-joint diaphragm for 6.0726.1XX and 6.0729.1XX reference electrodes
    • Spare ground-joint diaphragm for 6.0726.1XX and 6.0729.1XX reference electrodes
    • PCS
    • 1
    • Strand / 1 m / 2 x B
    • 6.2106.020
    • Electrode cable with 2 x plug B (4 mm) for connecting electrodes with plug-in head B
    • Electrode cable with 2 x plug B (4 mm) for connecting electrodes with plug-in head B
    • PCS
    • 1
    • Strand / 2 m / 2 x B
    • 6.2106.060
    • Electrode cable with 2 x plug B (4 mm) for connecting electrodes with plug-in head B
    • Electrode cable with 2 x plug B (4 mm) for connecting electrodes with plug-in head B
    • PCS
    • 1
    • Electrolyte 3 mol/L KCl (250 mL)
    • 6.2308.020
    • Electrolyte solution c(KCl) = 3 mol/L, (for Ag/AgCl reference systems)
    • Electrolyte solution c(KCl) = 3 mol/L, (for Ag/AgCl reference systems)
    • PCS
    • 1
    • Electrolyte KNO3-1mol/L 250 mL
    • 6.2310.010
    • Electrolyte solution KNO3 1 M (reference electrolyte for combined silver electrodes)
    • Electrolyte solution KNO<SUB>3</SUB> 1 M (reference electrolyte for combined silver electrodes)
    • PCS
    • 1
    • TEABr 0.4 mol/L in ethylene glycol (250 mL)
    • 6.2320.000
    • Electrolyte solution TEABr (tetraethylammonium bromide in ethylene glycol), c(TEABr) = 0.4 mol/L
    • Electrolyte solution TEABr (tetraethylammonium bromide in ethylene glycol), c(TEABr) = 0.4 mol/L
    • PCS
    • 1