IC equipment: Inline Ultrafiltration 2 - push mode
6.05330.110
-
- Ultrafiltration cell 2 holder
- 6.02057.030
- Holder for mounting the 6.02729.110 ultrafiltration cell 2 on the 858 Professional Sample Processor / 919 IC Autosampler plus.
- <p>Holder for mounting the 6.02729.110 ultrafiltration cell 2 on the 858 Professional Sample Processor / 919 IC Autosampler plus.</p>
- PCS
- 1
- Ultrafiltration cell 2
- 6.02729.110
- For the Inline ultrafiltration of samples together with the 858 Professional Sample Processor / 919 IC Autosampler plus. As an alternative to the time-consuming manual filtration with a syringe filter.
- <p>For the Inline ultrafiltration of samples together with the 858 Professional Sample Processor / 919 IC Autosampler plus. As an alternative to the time-consuming manual filtration with a syringe filter.</p>
- PCS
- 1
- PTFE capillary 0.5 mm i.d. / 1 m
- 6.1803.040
- Capillary for sample handling in IC.
- Capillary for sample handling in IC.
- PCS
- 2
- PTFE capillary 0.5 mm i.d. / 20 cm
- 6.1803.050
- Capillary for inline dialysis and filtration, for Dialysis Unit, IC Filtration Sample Processor
- Capillary for inline dialysis and filtration, for Dialysis Unit, IC Filtration Sample Processor
- PCS
- 2
- Pump tubing LFL (orange/yellow) , 3-stopper
- 6.1826.320
- For suppressor solutions and for acceptor solutions for inline dialysis and for inline ultrafiltration.
- <p>For suppressor solutions and for acceptor solutions for inline dialysis and for inline ultrafiltration.</p>
- PCS
- 1
- Pump tubing LFL (yellow/yellow), 3 stoppers
- 6.1826.390
- For the sample solution in Inline Ultrafiltration.
- For the sample solution in Inline Ultrafiltration.
- PCS
- 1
- PEEK capillary, 0.5 mm ID / 70 cm
- 6.1831.160
- PCS
- 1
- Hexagon key 4 mm
- 6.2621.030
- PCS
- 1
- Filtration membrane reg. cellulose, 0.2 µm, 50 pieces
- 6.2714.020
- Nominal pore size: 0.2 µm. Set of 50 pieces. For inline filtration.
- <p>Nominal pore size: 0.2 µm. Set of 50 pieces. For inline filtration.</p>
- PCS
- 1
- Pressure screw PVDF
- 6.2744.000
- With UNF 10/32 connection. For IC instruments, inline dialysis (connection of PTFE capillaries)
- With UNF 10/32 connection. For IC instruments, inline dialysis (connection of PTFE capillaries)
- PCS
- 1
- Coupling olive/UNF 10/32, 2x
- 6.2744.034
- Connection between pressure screw and pump tubing. 2 pieces. For IC instruments with peristaltic pump.
- <p>Connection between pressure screw and pump tubing. 2 pieces. For IC instruments with peristaltic pump.</p>
- PCS
- 1
- Pressure screw short
- 6.2744.070
- Short version. With UNF 10/32 connection. 5 pieces. For the connection of PEEK capillaries
- Short version. With UNF 10/32 connection. 5 pieces. For the connection of PEEK capillaries
- PCS
- 1
- Nozzle/UNF 10/32 coupling with security device
- 6.2744.160
- Security device for connecting pump tubing to a nozzle.
- Security device for connecting pump tubing to a nozzle.
- PCS
- 2
- Plastic tweezers
- 6.2831.010
- For dialysis and filtration membranes
- For dialysis and filtration membranes
- PCS
- 1
-
- Ultrafiltration cell 2 holder
- 6.02057.030
- Holder for mounting the 6.02729.110 ultrafiltration cell 2 on the 858 Professional Sample Processor / 919 IC Autosampler plus.
- <p>Holder for mounting the 6.02729.110 ultrafiltration cell 2 on the 858 Professional Sample Processor / 919 IC Autosampler plus.</p>
- PCS
- 1
- Ultrafiltration cell 2
- 6.02729.110
- For the Inline ultrafiltration of samples together with the 858 Professional Sample Processor / 919 IC Autosampler plus. As an alternative to the time-consuming manual filtration with a syringe filter.
- <p>For the Inline ultrafiltration of samples together with the 858 Professional Sample Processor / 919 IC Autosampler plus. As an alternative to the time-consuming manual filtration with a syringe filter.</p>
- PCS
- 1
- PTFE capillary 0.5 mm i.d. / 1 m
- 6.1803.040
- Capillary for sample handling in IC.
- Capillary for sample handling in IC.
- PCS
- 2
- PTFE capillary 0.5 mm i.d. / 20 cm
- 6.1803.050
- Capillary for inline dialysis and filtration, for Dialysis Unit, IC Filtration Sample Processor
- Capillary for inline dialysis and filtration, for Dialysis Unit, IC Filtration Sample Processor
- PCS
- 2
- Pump tubing LFL (orange/yellow) , 3-stopper
- 6.1826.320
- For suppressor solutions and for acceptor solutions for inline dialysis and for inline ultrafiltration.
- <p>For suppressor solutions and for acceptor solutions for inline dialysis and for inline ultrafiltration.</p>
- PCS
- 1
- Pump tubing LFL (yellow/yellow), 3 stoppers
- 6.1826.390
- For the sample solution in Inline Ultrafiltration.
- For the sample solution in Inline Ultrafiltration.
- PCS
- 1
- PEEK capillary, 0.5 mm ID / 70 cm
- 6.1831.160
- PCS
- 1
- Hexagon key 4 mm
- 6.2621.030
- PCS
- 1
- Filtration membrane reg. cellulose, 0.2 µm, 50 pieces
- 6.2714.020
- Nominal pore size: 0.2 µm. Set of 50 pieces. For inline filtration.
- <p>Nominal pore size: 0.2 µm. Set of 50 pieces. For inline filtration.</p>
- PCS
- 1
- Pressure screw PVDF
- 6.2744.000
- With UNF 10/32 connection. For IC instruments, inline dialysis (connection of PTFE capillaries)
- With UNF 10/32 connection. For IC instruments, inline dialysis (connection of PTFE capillaries)
- PCS
- 1
- Coupling olive/UNF 10/32, 2x
- 6.2744.034
- Connection between pressure screw and pump tubing. 2 pieces. For IC instruments with peristaltic pump.
- <p>Connection between pressure screw and pump tubing. 2 pieces. For IC instruments with peristaltic pump.</p>
- PCS
- 1
- Pressure screw short
- 6.2744.070
- Short version. With UNF 10/32 connection. 5 pieces. For the connection of PEEK capillaries
- Short version. With UNF 10/32 connection. 5 pieces. For the connection of PEEK capillaries
- PCS
- 1
- Nozzle/UNF 10/32 coupling with security device
- 6.2744.160
- Security device for connecting pump tubing to a nozzle.
- Security device for connecting pump tubing to a nozzle.
- PCS
- 2
- Plastic tweezers
- 6.2831.010
- For dialysis and filtration membranes
- For dialysis and filtration membranes
- PCS
- 1
-
- IC equipment: Inline dilution
- 6.5330.120
- Accessory set for Inline Dilution. For use with the 858 Professional Sample Processor, 800 Dosino and 741 Magnetic Stirrer.
- <p>Accessory set for Inline Dilution. For use with the 858 Professional Sample Processor, 800 Dosino and 741 Magnetic Stirrer.</p>
- PCS
- 1