Você foi redirecionado para a página solicitada
dPt ring electrode

dPt ring electrode

6.00403.300

dPt ring electrode

en

6.00403.300

Visão geral

Digital, combined platinum ring electrode for OMNIS with fixed ground-joint diaphragm.
This electrode is suitable for redox titrations when the pH value varies, e.g.:
 

  • Oxygen content according to Winkler
  • Determination of hydrogen peroxide with KMnO4
  • Diazotization titrations


The fixed ground-joint diaphragm is insensitive to contamination. c(KCl) = 3 mol/ L is used as reference electrolyte and for storage.
dTrodes can be used on OMNIS Titrators.

Especificações técnicas

Shaft materialGlass
Measuring range (theoretical)-2000 ... 2000
Measuring unitmV
Temperature range, long-term (°C)-5 ... 80
Temperature range, short-term (°C)-5 ... 80
pH range0...14
Max. installation length (mm)125
SGJ sleeveFlexible ground-joint sleeve
Shaft diameter top (mm)12
Shaft diameter bottom (mm)12
Min. immersion depth (mm)20
Electrode plug-in headMetrohm plug-in head Q
Indicator electrode typePt
Indicator electrode shapeRing
DiaphragmFixed ground-joint diaphragm
Reference electrolyte typec(KCl) = 3 mol/L
Electrolyte flow rate (μl/h) at 10 cm water column3 … 30
Reference systemLL system
Resistance (kOhm)< 5
Diaphragm resistance (kOhm)<2
Este campo é obrigatório.
    • Sleeve with SGJ 14/12 mm
    • 6.1236.050
    • Sleeve with SGJ 14/12 mm, polyethylene.
    • Sleeve with SGJ 14/12 mm, polyethylene.
    • PCS
    • 1
    • Storage vessel 
    • 6.2008.040
    • Together with 6.2008.050 storage vessel holder. it provides a support for the electrode on 807 Dosing Units.
    • <p>Together with 6.2008.050 storage vessel holder. it provides a support for the electrode on 807 Dosing Units.</p>
    • PCS
    • 1
    • Sleeve with SGJ 14/12 mm
    • 6.1236.050
    • Sleeve with SGJ 14/12 mm, polyethylene.
    • Sleeve with SGJ 14/12 mm, polyethylene.
    • PCS
    • 1
    • Storage vessel 
    • 6.2008.040
    • Together with 6.2008.050 storage vessel holder. it provides a support for the electrode on 807 Dosing Units.
    • <p>Together with 6.2008.050 storage vessel holder. it provides a support for the electrode on 807 Dosing Units.</p>
    • PCS
    • 1
    • Electrode cable plug-in head Q / plug P, 0.55 m
    • 6.02104.300
    • Cable for connecting a dTrode (plug-in head Q) to the digital measuring module from OMNIS.
    • <p>Cable for connecting a dTrode (plug-in head Q) to the digital measuring module from OMNIS.</p>
    • PCS
    • 1
    • Electrode cable plug-in head Q / plug P, 1.5 m
    • 6.02104.310
    • Cable for connecting a dTrode (plug-in head Q) to the digital measuring module from OMNIS.
    • <p>Cable for connecting a dTrode (plug-in head Q) to the digital measuring module from OMNIS.</p>
    • PCS
    • 1
    • Electrolyte 3 mol/L KCl (250 mL)
    • 6.2308.020
    • Electrolyte solution c(KCl) = 3 mol/L, (for Ag/AgCl reference systems)
    • Electrolyte solution c(KCl) = 3 mol/L, (for Ag/AgCl reference systems)
    • PCS
    • 1