Ag/AgCl reference electrode (length 12.5 cm)
6.0726.100
Ag/AgCl reference electrode (length 12.5 cm)
en
6.0726.100
Feature overview
Silver/silver chloride reference electrode with Double-Junction System, installation length 10 cm.
The standard ground-joint 14/15 enables easy assembly, and the flexible ground-joint diaphragm, which is insensitive to contamination, can be replaced at any time. The reference electrolyte and the bridge electrolyte can be selected freely according to use, and are easy to replace. This sensor is supplied without electrolyte filling.
Tech specs
| Shaft material | Glass |
|---|---|
| Temperature range, long-term (°C) | 0 ... 80 |
| Temperature range, short-term (°C) | 0 ... 80 |
| Max. installation length (mm) | 100 |
| SGJ sleeve | Standard ground-joint 14/15 |
| Shaft diameter top (mm) | 12 |
| Shaft diameter bottom (mm) | 12 |
| Min. immersion depth (mm) | 10 |
| Electrode plug-in head | Metrohm socket B |
| Diaphragm | Ground-joint diaphragm |
| Reference electrolyte type | variable |
| Bridge electrolyte type | variable |
| Reference system | Ag wire/AgCl |
| Electrolyte outflow (µL/h) with reference to 3 mol/L KCl | 5...50 |
| Reference resistance (kΩ) with reference to 3 mol/L KCl | <3 |
-
- Storage vessel
- 6.2008.040
- Together with 6.2008.050 storage vessel holder. it provides a support for the electrode on 807 Dosing Units.
- <p>Together with 6.2008.050 storage vessel holder. it provides a support for the electrode on 807 Dosing Units.</p>
- PCS
- 1
-
- Storage vessel
- 6.2008.040
- Together with 6.2008.050 storage vessel holder. it provides a support for the electrode on 807 Dosing Units.
- <p>Together with 6.2008.050 storage vessel holder. it provides a support for the electrode on 807 Dosing Units.</p>
- PCS
- 1
-
- Diaphragm for reference electrode
- 6.1243.030
- Spare ground-joint diaphragm for 6.0726.1XX and 6.0729.1XX reference electrodes
- Spare ground-joint diaphragm for 6.0726.1XX and 6.0729.1XX reference electrodes
- PCS
- 1
- Strand / 1 m / 2 x B
- 6.2106.020
- Electrode cable with 2 x plug B (4 mm) for connecting electrodes with plug-in head B
- Electrode cable with 2 x plug B (4 mm) for connecting electrodes with plug-in head B
- PCS
- 1
- Strand / 2 m / 2 x B
- 6.2106.060
- Electrode cable with 2 x plug B (4 mm) for connecting electrodes with plug-in head B
- Electrode cable with 2 x plug B (4 mm) for connecting electrodes with plug-in head B
- PCS
- 1
- Electrolyte 3 mol/L KCl (250 mL)
- 6.2308.020
- Electrolyte solution c(KCl) = 3 mol/L, (for Ag/AgCl reference systems)
- Electrolyte solution c(KCl) = 3 mol/L, (for Ag/AgCl reference systems)
- PCS
- 1
- Electrolyte KNO3-1mol/L 250 mL
- 6.2310.010
- Electrolyte solution KNO3 1 M (reference electrolyte for combined silver electrodes)
- Electrolyte solution KNO<SUB>3</SUB> 1 M (reference electrolyte for combined silver electrodes)
- PCS
- 1
- TEABr 0.4 mol/L in ethylene glycol (250 mL)
- 6.2320.000
- Electrolyte solution TEABr (tetraethylammonium bromide in ethylene glycol), c(TEABr) = 0.4 mol/L
- Electrolyte solution TEABr (tetraethylammonium bromide in ethylene glycol), c(TEABr) = 0.4 mol/L
- PCS
- 1