Combined Au ring electrode

Combined Au ring electrode

6.0452.100

Combined Au ring electrode

en

6.0452.100

Feature overview

Combined gold ring electrode with a ceramic pin diaphragm.
This is well suited for redox titrations when the pH value varies, e.g.:
 

  • for titrations using Hg(NO3)2
  • for titrations in presence of chromium or iron


c(KCl) = 3 mol/L is used as reference electrolyte and storage solution.

Tech specs

Shaft materialGlass
Measuring range (theoretical)–2000 ... 2000
Measuring unitmV
Temperature range, long-term (°C)–5 ... 80
Temperature range, short-term (°C)–5 ... 80
pH range0 ... 14
Max. installation length (mm)113
SGJ sleeveFlexible SGJ sleeve
Shaft diameter top (mm)12
Shaft diameter bottom (mm)12
Min. immersion depth (mm)15
Electrode plug-in headMetrohm plug-in head G
Indicator electrode typeAu
Indicator electrode shapeRing
DiaphragmCeramic diaphragm
Reference electrolyte typec(KCl) = 3 mol/L
Electrolyte flow rate (μl/h) at 10 cm water column10 ... 25
Reference systemLL system
Resistance (kOhm)5
Diaphragm resistance (kOhm)0.4 ... 0.9
This field is required.
    • Sleeve with SGJ 14/12 mm
    • 6.1236.050
    • Sleeve with SGJ 14/12 mm, polyethylene.
    • Sleeve with SGJ 14/12 mm, polyethylene.
    • PCS
    • 1
    • Storage vessel 
    • 6.2008.040
    • Together with 6.2008.050 storage vessel holder. it provides a support for the electrode on 807 Dosing Units.
    • <p>Together with 6.2008.050 storage vessel holder. it provides a support for the electrode on 807 Dosing Units.</p>
    • PCS
    • 1
    • Sleeve with SGJ 14/12 mm
    • 6.1236.050
    • Sleeve with SGJ 14/12 mm, polyethylene.
    • Sleeve with SGJ 14/12 mm, polyethylene.
    • PCS
    • 1
    • Storage vessel 
    • 6.2008.040
    • Together with 6.2008.050 storage vessel holder. it provides a support for the electrode on 807 Dosing Units.
    • <p>Together with 6.2008.050 storage vessel holder. it provides a support for the electrode on 807 Dosing Units.</p>
    • PCS
    • 1
    • Electrode cable / 1 m / F
    • 6.2104.020
    • For connecting electrodes with Metrohm plug-in head G to Metrohm instruments (socket F).
    • For connecting electrodes with Metrohm plug-in head G to Metrohm instruments (socket F).
    • PCS
    • 1
    • Electrolyte 3 mol/L KCl (250 mL)
    • 6.2308.020
    • Electrolyte solution c(KCl) = 3 mol/L, (for Ag/AgCl reference systems)
    • Electrolyte solution c(KCl) = 3 mol/L, (for Ag/AgCl reference systems)
    • PCS
    • 1