Unitrode easyClean with Pt1000 (fixed cable 2 m)
6.0260.020
Unitrode easyClean with Pt1000 (fixed cable 2 m)
en
6.0260.020
Feature overview
Combined pH electrode with easyClean diaphragm, integrated Pt1000 temperature sensor, and fixed cable (2.0 m). This electrode is particularly suitable:
- for automated pH measurements and titrations in difficult, viscous, or alkaline samples
- at elevated temperatures
- for long-term measurements
The easyClean diaphragm can be easily cleaned even in the case of heavily contaminating samples.
Reference electrolyte: c(KCl) = 3 mol/L, storage in storage solution.
Alternatively: reference electrolyte for measurements at T>80°C: Idrolyte, storage in Idrolyte.
Tech specs
| Shaft material | Glass |
|---|---|
| Measuring range (theoretical) | 0...14 |
| Measuring unit | pH |
| Temperature range, long-term (°C) | 0...100 |
| Temperature range, short-term (°C) | 0...100 |
| Max. installation length (mm) | 125 |
| SGJ sleeve | Flexible SGJ sleeve |
| Shaft diameter top (mm) | 12 |
| Shaft diameter bottom (mm) | 12 |
| Min. immersion depth (mm) | 20 |
| Electrode plug-in head | Fixed cable (l = 2 m) with plug F |
| Temperature sensor | Pt1000 |
| Indicator electrode shape | Hemisphere |
| Membrane glass type | U |
| Membrane resistance | 150...600 |
| Electrode zero point (mV) | ±15 |
| Electrode slope | >0.97 |
| Diaphragm | easyClean |
| Reference electrolyte type | c(KCl) = 3 mol/L |
| Electrolyte flow rate (μl/h) at 10 cm water column | 3...50 |
| Reference system | LL system |
| Resistance (kOhm) | < 5 |
-
- Sleeve with SGJ 14/12 mm
- 6.1236.050
- Sleeve with SGJ 14/12 mm, polyethylene.
- Sleeve with SGJ 14/12 mm, polyethylene.
- PCS
- 1
- Storage vessel
- 6.2008.040
- Together with 6.2008.050 storage vessel holder. it provides a support for the electrode on 807 Dosing Units.
- <p>Together with 6.2008.050 storage vessel holder. it provides a support for the electrode on 807 Dosing Units.</p>
- PCS
- 1
-
- Sleeve with SGJ 14/12 mm
- 6.1236.050
- Sleeve with SGJ 14/12 mm, polyethylene.
- Sleeve with SGJ 14/12 mm, polyethylene.
- PCS
- 1
- Storage vessel
- 6.2008.040
- Together with 6.2008.050 storage vessel holder. it provides a support for the electrode on 807 Dosing Units.
- <p>Together with 6.2008.050 storage vessel holder. it provides a support for the electrode on 807 Dosing Units.</p>
- PCS
- 1
-
- Electrolyte 3 mol/L KCl (250 mL)
- 6.2308.020
- Electrolyte solution c(KCl) = 3 mol/L, (for Ag/AgCl reference systems)
- Electrolyte solution c(KCl) = 3 mol/L, (for Ag/AgCl reference systems)
- PCS
- 1
- Idrolyte (250 mL)
- 6.2308.040
- Idrolyte (for 6.0224.100 Electrode and Unitrode at T >80°C)
- Idrolyte (for 6.0224.100 Electrode and Unitrode at T >80°C)
- PCS
- 1
- Storage solution
- 6.2323.000
- Storage solution for all combined pH glass electrodes with reference electrolyte c(KCl) = 3 mol/L
- Storage solution for all combined pH glass electrodes with reference electrolyte c(KCl) = 3 mol/L
- PCS
- 1
- pHit kit
- 6.2325.000
- Maintenance kit for pH electrodes The kit contains:50 mL cleaning solution; 50 mL 3M KCl solution; 50 mL storage solution; 2 Storage vessels; Instructions for use;
- <p>Maintenance kit for pH electrodes </p><p>The kit contains:</p><ul><li>50 mL cleaning solution</li><li>50 mL 3M KCl solution</li><li>50 mL storage solution</li><li>2 Storage vessels</li><li>Instructions for use</li></ul>
- PCS
- 1
- Cleaning solution 3 x 50 mL
- 6.2325.100
- Reliable measuring results over long periods of time can be guaranteed only if the pH glass membrane and the diaphragm receive preventive and regular care. Cleaning by etching with toxic chemicals or applying mechanical treatment to the diaphragm is not only complicated and expensive, it also accelerates the ageing of the pH glass electrode.The cleaning solution was developed for easy and gentle cleaning of pH glass electrodes. Regular use can considerably prolong their service life.This cleaning solution is also part of the pHit kit.
- <p>Reliable measuring results over long periods of time can be guaranteed only if the pH glass membrane and the diaphragm receive preventive and regular care. Cleaning by etching with toxic chemicals or applying mechanical treatment to the diaphragm is not only complicated and expensive, it also accelerates the ageing of the pH glass electrode.<br/>The cleaning solution was developed for easy and gentle cleaning of pH glass electrodes. Regular use can considerably prolong their service life.<br/><br/>This cleaning solution is also part of the pHit kit.</p>
- PCS
- 1