You have been redirected to your local version of the requested page
Ag Titrode with AgBr coating

Ag Titrode with AgBr coating

6.00430.100BR

Ag Titrode with AgBr coating

en

6.00430.100BR

Feature overview

Combined silver ring electrode with a pH glass membrane as reference electrode.
The silver ring is coated with bromide (AgBr) for a higher sensitivity and a better limit of detection.
This maintenance-free electrode is suitable for precipitation titrations when the pH value remains constant (titrant silver nitrate), for example of:
 

  • chloride, bromide, iodide
  • sulfides
  • hydrogen sulfide
  • mercaptans
  • cyanides


This electrode is stored in distilled water.

Tech specs

Shaft materialGlass
Measuring range (theoretical)-2000...2000
Measuring unitmV
Temperature range, long-term (°C)0...80
Temperature range, short-term (°C)0...80
pH range0...14
Max. installation length (mm)125
SGJ sleeveflexible
Shaft diameter top (mm)12
Shaft diameter bottom (mm)6
Min. immersion depth (mm)20
Electrode plug-in headMetrohm plug-in head G
Indicator electrode typeAg
Indicator electrode shapeRing
Reference systempH
    • Sleeve with SGJ 14/12 mm
    • 6.1236.050
    • Sleeve with SGJ 14/12 mm, polyethylene.
    • Sleeve with SGJ 14/12 mm, polyethylene.
    • PCS
    • 1
    • Storage vessel 
    • 6.2008.040
    • Together with 6.2008.050 storage vessel holder. it provides a support for the electrode on 807 Dosing Units.
    • <p>Together with 6.2008.050 storage vessel holder. it provides a support for the electrode on 807 Dosing Units.</p>
    • PCS
    • 1
    • Sleeve with SGJ 14/12 mm
    • 6.1236.050
    • Sleeve with SGJ 14/12 mm, polyethylene.
    • Sleeve with SGJ 14/12 mm, polyethylene.
    • PCS
    • 1
    • Storage vessel 
    • 6.2008.040
    • Together with 6.2008.050 storage vessel holder. it provides a support for the electrode on 807 Dosing Units.
    • <p>Together with 6.2008.050 storage vessel holder. it provides a support for the electrode on 807 Dosing Units.</p>
    • PCS
    • 1
    • Electrode cable plug-in head G / plug P, 0.55 m
    • 6.02104.000
    • Cable for connecting an analog electrode (plug-in head G) to an analog measuring module from OMNIS.
    • <p>Cable for connecting an analog electrode (plug-in head G) to an analog measuring module from OMNIS.</p>
    • PCS
    • 1
    • Electrode cable plug-in head G / plug P, 1.5 m
    • 6.02104.010
    • Cable for connecting an analog electrode (plug-in head G) to an analog measuring module from OMNIS.
    • <p>Cable for connecting an analog electrode (plug-in head G) to an analog measuring module from OMNIS.</p>
    • PCS
    • 1
    • Electrode cable / 1 m / F
    • 6.2104.020
    • For connecting electrodes with Metrohm plug-in head G to Metrohm instruments (socket F).
    • For connecting electrodes with Metrohm plug-in head G to Metrohm instruments (socket F).
    • PCS
    • 1