Porotrode with Pt1000 (connector U)

Porotrode with Pt1000 (connector U)

6.00235.600

Porotrode with Pt1000 (connector U)

en

6.00235.600

Feature overview

Combined pH electrode with integrated Pt1000 temperature sensor for pH measurements/titrations in:

samples containing protein (food, biological samples)
extremely contaminated samples
viscous samples
The specially developed capillary diaphragm and the reference electrolyte porolyte (6.2318.010) enable an optimum performance in samples containing protein. Storage in storage solution.

Tech specs

Shaft materialGlass
Measuring range (theoretical)0 ... 14
Measuring unitpH
Temperature range, long-term (°C)0 ... 80
Temperature range, short-term (°C)0 ... 80
pH range0 ... 14
Max. installation length (mm)125
SGJ sleeveFlexible ground-joint sleeve
Shaft diameter top (mm)12
Shaft diameter bottom (mm)12
Min. immersion depth (mm)20
Electrode plug-in headMetrohm plug-in head U
Temperature sensorPt1000
Indicator electrode typeGlass electrode
Indicator electrode shapeHemisphere
Membrane resistance200 ... 400
This field is required.
    • Porolyte 50 mL
    • 6.2318.010
    • Reference electrolyte porolyte for electrodes 6.0235.200 Porotrode and 6.00235.600 Porotrode with Pt1000.Replaces 6.2318.000 Porolyte 50 mL.
    • <p>Reference electrolyte porolyte for electrodes 6.0235.200 Porotrode and 6.00235.600 Porotrode with Pt1000.</p><p>Replaces 6.2318.000 Porolyte 50 mL.</p>
    • PCS
    • 1
    • Cleaning solution 3 x 50 mL
    • 6.2325.100
    • Reliable measuring results over long periods of time can be guaranteed only if the pH glass membrane and the diaphragm receive preventive and regular care. Cleaning by etching with toxic chemicals or applying mechanical treatment to the diaphragm is not only complicated and expensive, it also accelerates the ageing of the pH glass electrode.The cleaning solution was developed for easy and gentle cleaning of pH glass electrodes. Regular use can considerably prolong their service life.This cleaning solution is also part of the pHit kit.
    • <p>Reliable measuring results over long periods of time can be guaranteed only if the pH glass membrane and the diaphragm receive preventive and regular care. Cleaning by etching with toxic chemicals or applying mechanical treatment to the diaphragm is not only complicated and expensive, it also accelerates the ageing of the pH glass electrode.<br/>The cleaning solution was developed for easy and gentle cleaning of pH glass electrodes. Regular use can considerably prolong their service life.<br/><br/>This cleaning solution is also part of the pHit kit.</p>
    • PCS
    • 1