Application Finder
- AN-O-009Determination of eight organic acids and phosphate using the column Metrosep Organic Acids
Determination of organic acids and phosphate using ion-exclusion chromatography with direct conductivity detection.
- AN-O-042Organic acids in organic compounds using conductivity detection after inverse suppression
Arabinonic acid, glyceric acid, glycolic acid and formic acid can be determined in organic compounds using ion-exclusion chromatography with subsequent conductivity detection in accordance with inverse suppression. The Metrohm Suppressor Module in its lithium form is used for this purpose: This reduces background conductivity and ensures that the acids are present in their completely disassociated Li+ form. The suppressor is regenerated with lithium chloride.
- AN-O-046Organic acids in gas sweetening solvent by ion-exclusion chromatography with inverse suppression
Acidic gas sweetening solvents are used to remove acid gases such as H2S and CO2 from streams. Typically, amines are applied as alkaline components in these solvents. The determination of organic acids (glycolic, acetic, formic, propionic, and butyric acid) is achieved by ion-exclusion chromatography with conductivity detection after inverse suppression.
- AN-S-195Anions and organic acids with high pressure gradient
Determination of 21 anions and organic acids using anion chromatography with conductivity detection after chemical suppression and applying a high pressure gradient.
- AN-O-045Organic acids in monoethylene glycol by ion-exclusion chromatography with inverse suppression
Monoethylene glycol (MEG) is used to remove water from natural gas before further processing. Due to high temperatures applied, glycol degradation to glycolic, formic, and acetic acid may occur. These reactions are unwanted as the emerging acids are corrosive. The determination of the organic acids is achieved by ion-exclusion chromatography with conductivity detection after inverse suppression.
- AN-S-3414-Hydroxybutyrate in addition to standard anions and organic acids
4-Hydroxybutyrate (GHB) is numbered among the hydroxycarboxylic acids and is used as a psychoactive drug which is illegal in many countries. GHB can be determined through anion chromatography with suppression. GHB can be separated from the standard anions and the organic acid anions glycolate, acetate and formate on the Metrosep A Supp 16 - 250/4.0 column and under the conditions specific in this Application Note.Key words: Liquid Ecstasy, KO drops
- AN-S-362Organic acid anions in wine applying a low-pressure gradient
Organic acids in wine are omnipresent in winemaking. Some of them are present already in the grape while others appear during fermentation. The sum of organic acids and their composition have a direct influence on the taste of the respective wine. In this application a wine is tested for minor organic acids, especially shikimic and iso-citric, besides typical acids and anions. The separation is performed by anion chromatography applying a low-pressure gradient to achieve the required selectivity.
- 8.000.6011Ion chromatographic determination of anions, cations and organic acids in biofuels
Quality and process control of biofuels require straightforward, fast and accurate analysis methods. Ion chromatography (IC) is at the leading edge of this effort. Traces of anions in a gasoline/ethanol blend can accurately be determined in the sub-ppb range after Metrohm Inline Matrix Elimination using anion chromatography with conductivity detection after sequential suppression. While the analyte anions are retained on the preconcentration column, the interfering organic gasoline/bioethanol matrix is washed away.Detrimental alkali metals and water-extractable alkaline earth metals in biodiesel are determined in the sub-ppm range using cation chromatography with direct conductivity detection applying automated extraction with nitric acid and subsequent Metrohm Inline Dialysis. Unlike high-molecular substances, ions in the high-ionic strength matrix diffuse through a membrane into the low-ionic water acceptor solution. In biogas reactor samples, low-molecular-weight organic acids stem from the biodegradation of organic matter. Their profile allows important conclusions concerning conversion in the anaerobic digestion reaction. Volatile fatty acids and lactate can be accurately determined by using ion-exclusion chromatography with suppressed conductivity detection after inline dialysis or filtration.
- AN-S-311Organic acids in addition to standard anions in monoethylene glycol (MEG) applying a Dose-in Gradient
The separation of short-chain organic acids from fluoride and chloride requires diluted eluents. These weak eluents, however, induce long retention times for divalent anions. Adding a stronger eluent later in the separation sequence by use of a Dose-in Gradient makes these anions elute more rapidly. Furthermore, the Dose-in Gradient offers the advantage of low equipment and technical expense.
- AN-S-340Traces of organic acids in addition to standard anions with the aid of a dose-in gradient
Traces of organic acids can be determined only with difficulty in the presence of high concentrations of standard anions, because their small peaks generally disappear under the larger peaks of the standard anions. A simple dose-in-gradient improves the separation: acetate and formate are baseline-separated from fluoride. Furthermore, oxalate elutes considerably less than sulfate. The separation takes place on a column of the Metrosep A Supp 7 - 250/4.0 type with subsequent conductivity detection following sequential suppression.
- AN-S-33915 organic acids on the Metrosep A Supp 7 - 250/4.0 using a high-pressure gradient
High-pressure gradients combine the advantages of weak and concentrated eluents. Weak eluents promote the separation of the components that elute early and in close proximity to one another; in contrast to this, concentrated eluents accelerate the analysis of the components that are stronger retained at the column. The high-pressure gradient used in this application makes it possible to separate 15 organic acid anions in a single run. The blank subtraction option in the MagIC Net software simplifies the allocation of the peaks and with it the quantification.
- AN-S-310Short-chain organic acid anions in addition to standard anions applying a Dose-in Gradient and MiPuT
Formate, acetate, propionate, and butyrate in addition to standard anions are determined in a coal extract. To improve the separation of the early eluting organic acid anions, a Dose-in Gradient is applied. Due to the limited sample volume available, Metrohm intelligent Pick-up Technique (MiPuT) is also utilized.
- WP-086Measuring organic acids and inorganic anions with ion chromatography mass spectrometry
This White Paper focuses on selected IC-MS applications for the straightforward identification and quantification of organic acids and inorganic anions in different matrices.
- AN-O-037Organic acids in roasted coffee
Determination of citric, malic, quinic, succinic, lactic, formic, and acetic acid in roasted coffee using anion chromatography with conductivity detection after suppression.
- AN-O-021Six organic acids in paper industry process water
Determination of glycolic acid, formic acid, glutaric acid, acetic acid, propionic acid, and butyric acid in paper industry process water using ion-exclusion chromatography with suppressed conductivity detection.
- AN-O-022Seven organic acids in potato juice
Determination of acetic, propionic, isobutyric, butyric, isovaleric, valeric, and caproic acid in potato juice using ion-exclusion chromatography with suppressed conductivity detection.
- AN-O-029Organic acids in animal foodstuffs
Determination of fumarate, lactate, formate, and propionate in animal food using ion-exclusion chromatography with suppressed conductivity detection.
- AN-S-006Hypophosphite, phosphate, and organic acids in ethylene glycol
Determination of hypophosphite, formate, phosphate, adipate, p-nitrobenzoate, and sebacate in ethylene glycol using anion chromatography with conductivity detection after chemical suppression.
- AN-S-219Anions and organic acids in engine coolant
Determination of glycolate, formate, chloride, nitrite, nitrate, phosphate, sulfate, and oxalate in engine coolant using anion chromatography with conductivity detection after chemical suppression.
- AN-S-234Oxohalides and monovalent organic acids in the presence of standard anions
Determination of chlorite, bromate, chlorate, glycolate, acetate and formate in the presence of fluoride, chloride, nitrite, bromide, nitrate, phosphate and sulfate using anion chromatography and subsequent conductivity detection following chemical suppression.
- AN-S-112Five organic acids in fruit juice using chemical suppression after ion-exclusion separation
Determination of citrate, malate, succinate, lactate, and acetate using ion-exclusion chromatography with conductivity detection after chemical suppression.
- AN-S-252Standard anions and organic acids in Bayer liquor using inline matrix neutralization
Determination of fluoride, acetate, formate, chloride, sulfate, malonate, succinate, and oxalate in Bayer liquor using anion chromatography with conductivity detection after sequential suppression.
- AN-O-039Organic acids in samples from biogas production by ion-exclusion chromatography after dialysis
Determination of formate, acetate, propionate, isobutyrate, butyrate, isovaleriate, valeriate, and capronate using ion-exclusion chromatography with suppressed conductivity detection after inline dialysis.
- AN-O-036The use of the Metrohm CO2 Suppressor (MCS) in the determination of organic acids
Determination of formate, acetate, propionate, isobutyrate, butyrate, isovalerate, valerate, and capronate added to tap water using anion chromatography with conductivity detection after suppression. The MCS is placed upstream of the chemical suppressor to remove interfering CO2.
- AN-S-319Fast IC: separation of organic acid anions as well as sulfate in three minutes
Fast IC means a high sample throughput. This is attained with short columns, relatively high flows and strong eluents. Malate, tartrate, oxalate as well as sulfate are separated within three minutes.
- 8.000.6041Simultaneous determination of fluoride species plus acid anions in etching baths by ion chromatography with dual detection
This poster presents a straightforward ion chromatographic determination of HF, HNO3, short-chain organic acids and H2SiF6 in etching bath samples. Standard ions such as fluoride, nitrate, acetate and sulfate are determined via suppressed conductivity detection while dissolved silicate is spectrophotometrically detected in the same run after downstream post-column reaction (PCR) as molybdosilicic acid. Analytical results of several commercial HF-HNO3-H2SiF6 mixtures obtained by ion chromatography (IC) and titration showed good agreement, which confirms the applicability of the presented «dual» detection IC method for controlling the composition of acidic texturing baths.
- AN-CIC-007Analysis of a standard mixed in liquid using Metrohm Combustion IC
This application describes the determination of fluoride, chloride, bromide and sulfur (as sulfate) in an ethanol standard solution with halo organic (4-halogen benzoic acids; F, Cl and Br) and sulfur organic compounds (3-(Cyclohexylamino)-1-propanesulfonic acid) by means of Metrohm Combustion Ion Chromatography with flame sensor and Inline Matrix Elimination.Keyword: pyrohydrolysis
- AN-S-396Assessing wine quality with IC
Monitoring the range of organic acids in wine is crucial to improve flavor and quality, and to fulfill universal standardized criteria such as the International Code of Oenological Practices. Analytically, organic acids can be properly determined with ion chromatography (IC) and suppressed conductivity detection. As a multicomponent method, inorganic acids can also be resolved which are also valuable tracers for wine quality and taste. This Application Note presents two IC methods for wine quality analysis: a fast isocratic screening method of major organic acids and anions including sulfite, and a complex monitoring method with a binary gradient to separate 15 organic acids. Inline Ultrafiltration was used for economical sample treatment.
- AN-CIC-029Organic halides in crude oil
Crude oil typically contains no organic halides. These are introduced at production sites, in pipelines, or in storage tanks. These components produce HF, HCl, and other acids in reforming and hydro-treating processes, leading to corrosion and catalyst poisoning. Speciation of the halides is an important parameter to measure in order to trace the contamination source. The current specifications expect to find less than 2 mg/kg organic chlorine in crude oil. Sulfur in crude oil could be quantified on the fly. Due to the specific request in this application, only the halogens are determined.
- AN-S-309Anions in 70% hydrogen peroxide applying Inline Matrix Elimination
Hydrogen peroxide is used as a cleaning, oxidizing and bleaching agent. Depending on its purity, it may contain inorganic anions as well as organic acid anions, such as oxalate, phthalate, and dipicolinic acid. Dipicolinic acid is a complexing agent that binds transition metal cations and is sometimes added to increase the stability of hydrogen peroxide.
- AN-N-007Acetate and methanesulfonate in an organic disodium salt
Determination of acetate and methansulfonate in an organic salt using anion chromatography with direct conductivity detection.
- TA-019Simultaneous determination of mineral acids, fluoride and silicate in etching baths.
This article describes an ion chromatography method for the simultaneous determination of HF, HNO3, H2SO4, short-chain organic acids, and of H2SiF6 in acid texturing baths.
- AN-C-180Bicine in gas sweetening solvent by cation chromatography
Bicine (2-(Bis(2-hydroxyethyl)amino)acetic acid) is a corrosive component. It has to be avoided in acidic gas sweetening solvents. These solvents are based on organic amines. Bicine is amphoteric, holding a carboxylic and an amine group. Under the applied conditions, the amine groups are at least partially protonated and therefore may be separated by cation chromatography. The detection mode is direct conductivity detection.
- AB-073Polarographic analysis – half-wave potentials of organic substances
This Bulletin is a supplement to Application Bulletin no. 36 (Half-wave potentials of inorganic substances) in the sense that the half-wave potentials of 100 different organic substances are listed. At the same time the supporting electrolytes used and the limits of determination are given.The various substances are listed in alphabetical order. The most important polarographically active functional groups are taken into consideration. This means that substances for related structures can also be determined polarographically in the same or similar supporting electrolytes, although they may not appear in the list.Unless otherwise stated, the half-wave potentials refer to a temperature of 20 °C, and the potentials are given in volts, measured with a sat. KCI-Ag/AgCl electrode assembly.The determination limits give the smallest concentrations which can be measured without risking serious errors in the results. In all cases, the limit of detection lies below the limit of determination.
- AN-T-242Acidity in aviation turbine fuel according to ASTM D3242
This application presents the fully automated determination of acidity in jet fuel as per ASTM D3242 via photometric titration with an automatic titrator and the Optrode.
- AN-S-281Inorganic and organic anions in wine applying Inline Ultrafiltration
Product consistency and quality is of utmost importance to winemakers. This wine analysis evaluates nutrients and other ionic ingredients, which could potentially have deleterious effects on efficiency and production during the fermentation process. Inorganic and organic anions as acetate, chloride, phosphate, malate, sulfite, tartrate, sulfate, and oxalate are separated and quantified on a Metrosep A Supp 10 - 100/4.0 applying Inline Ultrafiltration and conductivity detection.
- 8.000.6112Technical Poster: Haloacetic acids in water
LC-MS/MS quantification methods are commonly used to determine trace levels of organic compounds. However, highly polar reversed phases (RPs) lack sufficient retention for very polar compounds, or they fail for charged organics. Separation using ion chromatography (IC) and subsequent MS/MS detection is an innovative alternative approach that combines the fast elution and flexibility of the IC system with the excellent resolution and high sensitivity of the MS/MS detector. This poster presents a fast, robust and reliable IC-MS/MS method for the detection of HAAs and other ionic analytes using the high-end MS/MS system QTRAP 6500+ from SCIEX coupled to a the 940 Professional IC Vario One SeS/PP/HPG instrument. This analytical setup is able to identify and quantify the presence of HAAs at trace levels with LLODs between 0.02 μg/mL and 0.2 μg/L on a single HAA. This capability easily fulfills the sensitivity requirements specified in EU Drinking Water Directive, which specifies a maximum residue level (MRL) of 60 mg/mL for the sum of monochloroacetic acid, dichloroacetic acid, trichloroacetic acid, monobromoacetic acid and dibromoacetic acid present in the representative sample.
- AN-M-016Resolving haloacetic acids in water
During drinking water disinfection with chlorine, chloramine, or ozone, potentially toxic halogenated byproducts can be formed. The disinfectants can react with naturally occurring bromide and/or organic matter in the source water and form one of the most common and highly toxic disinfection byproducts (DBPs): haloacetic acids (HAAs). To protect human health, maximum tolerable levels of HAA in drinking waters are regulated (EPA 816-F-09-004). The EPA Method 557 specifies the analysis of HAAs beside bromate and dalapon by ion chromatography coupled to tandem mass spectroscopy (IC-MS/MS) with LODs varying from 0.02–0.11 µg/L. However, even with single MS, a high sensitivity is achieved to determine the current MCLs within an adequate accuracy. This Application Note describes the analysis of bromate, chlorite, monochloroacetic acid (MCAA), monobromoacetic acid (MBAA), bromochloroacetic acid (BCAA), bromodichloroacetic acid (BDCAA), dibromoacetic acid (DBAA), dichloroacetic acid (DCAA), tribromoacetic acid (TBAA), chlorodibromoacetic acid (CDBAA), and trichloroacetic acid (TCAA) with IC/MS. The Metrohm Driver 2.1 for EmpowerTM offers the analysis as a single software solution with EmpowerTM.
- WP-066An introduction to ion chromatography mass spectrometry (IC-MS)
Ion chromatography mass spectrometry (IC-MS) is a powerful tool that can handle many challenging analytical tasks which cannot be performed adequately by IC alone. IC-MS is a robust, sensitive, and selective technique used for the determination of polar contaminants like inorganic anions, organic acids, haloacetic acids, oxyhalides, or alkali and alkaline earth metals. After separation of the sample components via IC, mass selective detection guarantees peak identity with low detection limits. The inclusion of automated Metrohm Inline Sample Preparation (MISP) allows not only water samples, but also chemicals, organic solvents, or post-explosion residues to be readily analyzed without need for extensive manual laboratory work. This White Paper explains the benefits of IC-MS over IC in certain cases, the hyphenation of IC and different MS systems, as well as related norms and standards.
- WP-039Ion chromatography – addressing the latest challenges in environmental analysis
The analytical challenges of environmental analysis increase in difficulty from year to year. As well as analysis of particularly toxic types of metals such as chromium(VI), highly diverse and partially persistent organic fluorine compounds (e.g., trifluoroacetic acid) are presently in focus. The analysis of toxic oxohalides such as bromate and perchlorate is also a current subject of investigation.
- 8.000.6005Hyphenated techniques as modern detection systems in ion chromatography
The coupling of highly efficient ion chromatography (IC) to multi-dimensional detectors such as a mass spectrometer (MS) or an inductively coupled plasma mass spectrometer (ICP/MS) significantly increases sensitivity while simultaneously reducing possible matrix interference to the absolute minimum. By means of IC/MS several oxyhalides such as bromate and perchlorate can be detected in the sub-ppb range. Additionally, organic acids can be precisely quantified through mass-based determination even in the presence of high salt matrices. By means of IC-ICP/MS different valence states of the potentially hazardous chromium, arsenic and selenium in the form of inorganic and organic species can be sensitively and unambiguously identified in one single run.
- AN-H-115Determination of hydrofluoric acid, ammonium fluoride, and maleic acid in acid cleaning solutions
A direct thermometric titration (TET) with 2 mol/L NaOH is used to determine the HF, NH4F, and maleic acid (C4H4O4) contents of acid cleaning solutions. Three endpoints (EPs) are obtained, which may be assigned as follows:EP1: C4H4O4 (pKa1 = 1.9), HF (pKa = 3.17)EP2: C4H4O4 (pKa2 = 6.07)EP2: NH4F (pKa = 8.2)The HF content is determined by subtracting the difference (EP2-EP1) from EP1.
- AN-H-065Determination of salts of carboxylic acids by aqueous acidometric titration
Determination of sodium and potassium salts of carboxylic acids in aqueous media. May be used for analysis of reagent purity.
- AN-O-017Glycolic acid, formic acid, acetic acid and carbonic acid in a scrubber solution
Determination of glycolic acid, formic acid, acetic acid and carbonic acid in a scrubber solution using ion-exclusion chromatography with conductivity detection after chemical suppression.
- AN-T-203Acidity in volatile solvents and chemical intermediates
The presence of acidic components in volatile solvents could be a result of contamination, decomposition during storage, distribution or manufacture. An increased acid content in solvents could lead to a variety of problems like shorter storage stability or chemical corrosion. Using the Optrode for indication, the acidity is determined by photometric titration with sodium hydroxide as titrant and phenolphthalein as indicator. If the volatile solvent is water soluble, it is dissolved in deionized water, if not, it is dissolved in carbon-dioxide free ethanol.
- AN-H-027Determination of organic soda in Bayer aluminate liquors
Determination of total basicity of extractable organic compounds of acidic character in Bayer process refinery liquors.
- AN-O-001Fatty acids (C12 ... C18) with ion-pair chromatography
Determination of lauric acid, myristic acid, palmitic acid, and stearic acid using ion-pair chromatography with direct conductivity detection.
- AN-O-010Gluconic acid and glycolic acid
Determination of gluconic acid and glycolic acid using ion-exclusion chromatography with direct conductivity detection.
- AN-T-042Citric and oxalic acid in mixtures
Citric acid and oxalic acid are present in many products, such as foods or chemical solvents (e.g., decontamination solutions). Both acids are reducing agents and citric acid is additionally a powerful antioxidant. Due to their mutual impact (buffer effect), a content calculation is only possible with correction factors for each acid. A fast and accurate determination by potentiometric titration using the dEcotrode plus and sodium hydroxide as titrant can be realized in this Application Note.
- AN-O-018Boric acid and acetic acid in process water
Determination of boric acid and acetic acid in process water using ion-exclusion chromatography with conductivity detection after chemical suppression.
- AN-N-002Determination of methylarsonic acid and dimethylarsinic acid
Determination of methylarsonic acid and dimethylarsinic acid using anion chromatography with direct conductivity detection.
- AN-H-036Determination of free fatty acids (FFA) in olive oil
Determination of free fatty acids (FFA) in oils.
- AN-O-008Citric acid and tartaric acid in fruit salt
Determination of citric acid and tartaric acid in fruit salt using ion-exclusion chromatography with direct conductivity detection.
- AN-NIR-091Quality Control of Mixed Acetic, Hydrofluoric, and Nitric Acids
This application note discusses an alternative near-infrared (NIR) spectroscopy method that can reliably determine all parameters within a minute, even in complex acid mixtures.
- AN-T-234Direct comparison of OMNIS and Titrando for mixed acids and TMAH
This Application Note compares the OMNIS Titrator and 888 Titrando for determinations of nitric acid, phosphoric acid, and acetic acid in an aluminum etching bath, as well as the determination of tetramethylammonium hydroxide (TMAH). Identical analysis parameters were used, showing that OMNIS delivers results on par or even better than with other established titration systems.
- AN-S-143Glycerophosphates in amino acids
Determination of α-glycerophosphate and β-glycerophosphate in amino acids using anion chromatography with conductivity detection after chemical suppression.
- AN-O-020Citric acid and lactic acid in an electroplating bath
Determination of citric acid and lactic acid in an electroplating bath using ion-exclusion chromatography with conductivity detection.
- AN-T-154Determination of alpha acids in hops according to EBC 7.4
The alpha acid level (AA%) in hops plays a major role in the bitterness they can impart to beer. The AA% can vary between 1% up to 20% in hops. During boiling in the brewing process, alpha acids transform into iso-alpha acids which make the beer bitter. For this reason, it is important for brewers to know the exact AA value of the hops they use. The determination of AA% in hops with conductometric titration according to the EBC method 7.4 is shown in this Application Note.
- AN-C-178Aspartic acid, glutamic acid, TRIS, sodium, and potassium in cardioplegic solution
A cardioplegic solution protects the ischemic myocardium from cell death. It is applied together with hypothermia e.g. in open heart surgery. Here the simultaneous determination of aspartic acid, glutamic acid, tris(aminomethyl)aminomethane (TRIS), sodium and potassium in such a solution is given. The two amino acids can be determined as they are partially in the triple protonated ammonium form at the eluent pH. Determination is achieved by direct conductivity detection.
- AN-O-002Glycolic acid and monochloroacetic acid in cocoamidopropyl betaine
Determination of glycolic acid and monochloroacetic acid in cocoamidopropyl betaine using ion-exclusion chromatography with direct conductometric detection.
- AN-O-007Citric acid and ascorbic acid in vitamin tablets
Determination of citric acid and ascorbic acid in vitamin tablets using ion-exclusion chromatography with direct conductivity detection.
- AN-S-089Acetate and dichloroacetate in monochloroacetic acid
Determination of acetate and dichloroacetate in chloroacetic acid using anion chromatography with conductivity detection after chemical suppression.
- AN-N-051Acetate, chloride, citrate, and sulfate in a concentrate of an infusion solution containing amino acids and dipeptides
Determination of acetate, chloride, citrate, and sulfate in a concentrate of an infusion solution using anion chromatography with direct conductivity detection. Non-suppressed IC is used to avoid interferences by the amino acids.
- AN-RS-009Verification of fatty acids in functional foods and cosmetics
Determination of the identity and purity of ingredients is essential for the product quality of functional foods (neutraceuticals) and cosmetics. It prevents the utilization of inferior substances in the production process and thus avoids expensive delays and out-of-spec products. This Application Note describes the identification and checking of fatty acids in functional foods and cosmetics using the Metrohm Instant Raman Analyzer MIRA P.
- AN-H-143Sulfuric acid and tartaric acid in tartaric sulfuric anodizing bath – Rapid, sequential determination using a thermometric sensor (thermometric titration)
Tartaric Sulfuric Anodizing (TSA) is an established technique for corrosion protection in the aerospace industry. It is an alternative to the environmentally harmful chromic anodizing process. As such, a method to monitor the levels of sulfuric acid and tartaric acid in TSA plating baths is required. Potentiometric titration methods have been developed, and are widely used across the industry. Their disadvantage is that two titrations with different electrodes and solvents are required.In this Application Note, an alternative method is presented, where the concentration of both acids is determined in sequence using a thermometric sensor. Compared to potentiometric titration, thermometric titration is faster and more convenient (no sensor maintenance required). On a fully automated system, the determination of both parameters takes about 7 minutes.
- AN-S-064Glycolate, acetate, and chloride in monochloroacetic acid
Determination of glycolate, acetate, and chloride in monochloroacetic acid (MCA) using anion chromatography with conductivity detection after chemical suppression.
- 8.000.6014Determination of anions and cations in aerosols by ion chromatography
The study of adverse effects of air pollution requires semi-continuous, rapid and accurate measurements of inorganic species in aerosols and their gas phase components in ambient air. The most promising instruments, often referred to as steam collecting devices, are the Particle-Into-Liquid-Sampler (PILS) coupled to wet-chemical analyzers such as a cation and/or anion chromatograph (IC) and the Monitoring instrument for AeRosols and GAses (MARGA) with two integrated ICs. Both instruments comprise gas denuders, a condensation particle growth sampler as well as pump and control devices. While PILS uses two consecutive fixed denuders and a downstream growth chamber, the MARGA system is composed of a Wet Rotating Denuder (WRD) and a Steam-Jet Aerosol Collector (SJAC). Although the aerosol samplers of PILS and MARGA use different assemblies, both apply the technique of growing aerosol particles into droplets in a supersaturated water vapor environment. Previously mixed with carrier water, the collected droplets are continuously fed into sample loops or preconcentration columns for on-line IC analysis. While PILS has been designed to sample aerosols only, MARGA additionally determines water-soluble gases. Compared to the classical denuders, which remove gases from the air sample upstream of the growth chamber, MARGA collects the gaseous species in a WRD for on-line analysis. In contrast to the gases, aerosols have low diffusion speeds and thus neither dissolve in the PILS denuders nor in the WRD. Proper selection of the ion chromatographic conditions of PILS-IC allows a precise determination, within 4 to 5 minutes, of seven major inorganic species (Na+, K+, Ca2+, Mg2+, Cl-, NO3- and SO4 2-) in fine aerosol particles. With longer analysis times (10-15 minutes) even airborne low-molecular-weight organic acids, such as acetate, formate and oxalate can be analyzed. MARGA additionally facilitates the simultaneous determination of HCl, HNO3, HNO2, SO2 and NH3.PILS and MARGA provide semi-continuous, long-term stand-alone measurements (1 week) and can measure particulate pollutants in the ng/m3 range.
- AN-T-192Determination of acid-neutralizing capacity according to USP<301>
This Application Note details the determination of acid-neutralizing capacity (ANC) in several pharmaceutical samples in compliance with USP<301> standards.
- AN-O-041The concentration of maleic acid and kojic acid in starch through UV/VIS detection in accordance with ion-exclusion chromatography
Evidence of maleic acid in Asian foodstuffs led to the recall of many starchy foods because long-term consumption of maleic acid can cause kidney problems. Cyclic kojic acid is however approved in Asia, both as a bleaching additive in foodstuffs and as a preservative in cosmetics. This Note describes their simultaneous determination in a single analysis.
- AN-M-001Aliphatic monocarboxylic acids in produced water using IC/MS coupling
Determination of acetic, propionic, butyric, valeric, and caproic acid in produced water using anion chromatography with conductivity and MS detection after post-column addition of ammonia for MS detection and inline sample preparation by dialysis.
- AB-190Determination of 4-carboxybenzaldehyde in terephthalic acid by polarography
4-Carboxybenzaldehyde, in the following referred to as 4-CBA, can be reduced directly at the dropping mercury electrode (DME) in an ammoniacal solution. After a very simple sample preparation it is now possible to determine the concentration of 4-CBA in terephthalic acid quickly and precisely by polarography down to the lower ppm range.
- AN-S-136Adipic and phthalic acid in a digestion solution
Determination of adipic acid and phthalic acid in an alkaline ester digestion solution using anion chromatography with conductivity detection after chemical suppression.
- AN-S-246Sulfate in methanedisulfonic acid
Determination of sulfate in methanedisulfonic acid using anion chromatography with conductivity detection after sequential suppression.
- AN-T-035Tranexamic acid in injection solutions
Determination of tranexamic acid in injection solutions by nonaqueous potentiometric titration with perchloric acid using a glass electrode.
- AN-PAN-1062Online monitoring of sulfuric acid and hydrogen peroxide using Raman spectroscopy
Etching is a vital process in semiconductor fabrication, involving the chemical removal of layers from the wafer substrate. Strict quality control measures are necessary to determine acid etchant concentrations in mixed acid solutions (e.g., SPM, DSP, or DSP+), critical for optimizing etch rate, selectivity, and uniformity during multiple wafer etching steps. This application presents a method to measure sulfuric acid and hydrogen peroxide in etching baths simultaneously using Raman spectroscopy with the PTRam Analyzer from Metrohm Process Analytics.
- AN-H-024Determination of tar acids (phenolics) in tar products
Determination of tar acids in coal tar products. This procedure may also be applied to the determination of a range of weakly acidic organic compounds such as carboxylic acids, hydroxy acids, phenols, phenolic acids, keto-enols, imides, and aromatic nitro compounds.11 Vaughan, G. A. Thermometric and Enthalpimetric Titrimetry. Van Nostrand Reinhold Co. Ltd (1973)
- AB-179Polarographic determination of maleic and fumaric acid alone or in mixtures
Maleic and fumaric acid can be reduced electrochemically to succinic acid. In acidic solutions a differentiation of the two acids is not possible since both are reduced at the same potential. On the other hand, separation at pH 7.8...8.0 is easily possible since fumaric acid is now more difficult to reduce at the lower proton concentration (as a result of cis-trans isomerism) than maleic acid.
- 8.000.6034Determination of the sodium contribution of solvent-extractable organic compounds in Bayer process liquor
This poster presents a highly reproducible procedure for the determination of the sodium contribution of acid-extractable organic species in Bayer process liquor. The precision of the method is estimated to be 0.2% RSD.
- AN-V-070Determination of iodide in glacial acetic acid
Iodide contamination in glacial acetic acid poses risks for downstream processes. Cathodic stripping voltammetry (CSV) at the HMDE offers reliable iodide measurement.
- AN-S-146Chloride and sulfate in succinic acid
Determination of chloride and sulfate in succinic acid using anion chromatography with conductivity detection after chemical suppression.
- AN-S-137Fluoride in adipic acid
Determination of fluoride in adipic acid using anion chromatography with conductivity detection after chemical suppression.
- AN-S-209Fluoride, methlysulfonic, ethyldisulfonic, and methyldisulfonic acid in chromium plating baths
Determination of fluoride, MSA (methylsulfonic acid), EDSA (ethyldisulfonic acid), and MDSA (methyldisulfonic acid) using anion chromatography with conductivity detection after chemical suppression.
- AN-V-056Ascorbic acid in vitamin capsules
Determination of ascorbic acid (vitamin C) in vitamin capsules after sample digestion.
- AN-PAN-1029Monitoring peracetic acid (PAA) in a beverage bottling facility
Precise online monitoring of peracetic acid (PPA) for beverage bottling requires a reliable stainless steel process analyzer.
- AN-U-028Salicylic acid impurity in aspirin tablets according to the USP method
Determination of salicylic acid and acetylsalicylic acid according to USP 28-NF 23 (second supplement) using RP chromatography with UV detection.
- AN-T-114Iodometric determination of ascorbic acid in orange juice
This Application Note describes the iodometric, bivoltametric determination of ascorbic acid in orange juice using the Double Pt-sheet electrode.
- AN-U-003Glycolic and lactic acid in the presence of N-methyl pyrrolidone
Determination of glycolic and lactic acid in the presence of N-methyl pyrrolidone used in drug delivery systems using ion-exclusion chromatography with UV/VIS detection.
- AN-N-038Traces of iodide in acetic acid using amperometric detection
Determination of traces of iodide in acetic acid using anion chromatography with amperometric detection at the carbon paste electrode.
- AN-V-006Cadmium, lead, and antimony in acetic acid
Determination of Cd, Pb, and Sb in acetic acid.
- AN-S-063Phosphate and phosphite in poly(vinylphosphonic acid) using dialysis for sample preparation
Determination of phosphate and phosphite in poly(phosphonic acid) using anion chromatography with conductivity detection after chemical suppression and dialysis for sample preparation.
- AN-S-315Methanedisulfonic acid in chromium baths using nested dilution, Dosino Regeneration and STREAM
Methanedisulfonic acid (MDSA) is used as a catalyst in chromium plating baths. The MDSA concentration in the bath must be known in order to monitor the chromating. The analysis of a bath sample requires dilution by a factor of 2,500. This Application Note shows the automatic Inline Dilution that takes place in two steps. While one sample is being analyzed, the time-optimized dilution of the next sample is already running. The MSM is regenerated using an 800 Dosino and the STREAM setup: The eluent is used for rinsing the regenerated MSM after exiting the detector.
- AN-S-388Assay for citric acid/citrate and phosphate according to USP <345>
In the course of USP column equivalency tests, the Metrosep A Supp 3 - 250/4.0 is applied for the assay of citric acid/citrate and phosphate according to USP general Chapter <345>. This report shows that the Metrosep A Supp 3 - 250/4.0 column is equivalent to packing L61 required in USP general Chapter <345>.
- AN-NIR-150Monitoring the production of stearic acid and its salts with NIR spectroscopy
Stearic acid and stearate derivatives are produced through multistep processing and require monitoring of key quality attributes, including iodine value, acid value, moisture, ash content, melting point, and granulometry. This study demonstrates that near-infrared (NIR) spectroscopy with the OMNIS NIR Analyzer enables rapid, nondestructive quantitative analysis of these parameters for both in-process and final-product samples.
- AN-C-179Cations and lactic acid in whey powder applying two separation mechanisms in the same analysis
Whey is the remaining liquid after cheese production. It is mainly used as feed. It is also used as dietary supplement as a beverage or in powder form. This application determines lactic acid as well as cations in one determination. The Metrosep C 6 - 250/4.0 column separates sodium, potassium, magnesium, and calcium by ion exchange. It also acts as an ion-exclusion column, which separates lactic acid. Both lactic acid and the cations can be determined in the same run applying direct conductivity detection. While cations typically elute as negative peaks, lactic acid elutes as an early positive peak. MagIC Net shows both in the usual positive direction.
- AN-T-115Bivoltametric titration with 2,6-dichlorophenol indophenol for the determination of ascorbic acid in orange juice
This Application Note describes the bivoltametric titration of ascorbic acid in orange juice. 2,6-dichlorophenol indophenol (DPIP) is used as titrant; endpoint determination takes place using the Double Pt-sheet electrode.
- AB-215Determination of folic acid by polarography
This Application Bulletin describes the polarographic determination of folic acid, a vitamin of the B series, also known as vitamin B9 or vitamin BC. Instructions for the determination in solutions (e.g. fruit juice), vitamin capsules and multivitamin tablets are given. The linear range of the determination is also specified. The limit of detection is approx. 75 µg/L folic acid.
- AN-P-077Proof of concept for the determination of lactose and its derivatives as well as sialic acid* in fermentation broths
The separation of lactose, lactobionic acid, sialic acid*, 6’-sialyllactose, and 3’-sialyllactose is shown as a proof of concept for the control of these components in fermentation process for a pharmaceutical product. The acceptance criterion of a minimum resolution of the peaks (< 1.3) is reached. The separation is achieved on a Metrosep Carb 2 - 250/4.0 column with subsequent pulsed amperometric detection.
- AN-N-008Five anions in an organic solvent (toluene)
Determination of acetate, formate, chloride, bromide, and sulfate in toluene using anion chromatography with direct conductivity detection.
- AB-076Polarographic determination of nitrilotriacetic acid (NTA) and ethylenediaminetetraacetic acid (EDTA) according to DIN 38413 part 5
According to the described method, NTA and EDTA can be determined in mass concentrations of 0.05 mg/L up to 25 mg/L in polluted water and wastewater.At first NTA and EDTA are converted to the corresponding Bi complexes by addition of Bi3+ ions at a pH value of 2.0. As these Bi complexes have significantly different peak potentials, they can be determined simultaneously by DP polarography. The interfering anions nitrite, sulfite, and sulfide are removed from the sample by acidification and purging. Interfering cations are removed by cation exchange; any NTA or EDTA heavy metal complexes present in the sample are disintegrated during this procedure. To remove surfactants and other organic components interfering with the analysis, the sample solution is run through a column filled with non-polar adsorber resin.
- AN-O-016Separation of eight carboxylic acids
Determination of lactate, formate, acetate, propionate, butyrate, isobutyrate, valerate,and isovalerate in a standard solution using ion-exclusion chromatography with conductivity detection after chemical suppression.
- AN-O-015C1 ... C6 carboxylic acids in aqueous absorption solutions
Determination of formate, acetate, propionate, butyrate, valerate, and capronate in an aqueous absorption solution using ion-exclusion chromatography with conductivity detection after chemical suppression.
- AN-V-0624-Carboxybenzaldehyde in polyterephthalic acid
4-Carboxybenzaldehyde can be reduced directly on the DME in a solution containing ammonium.
- AN-V-003Nickel, cobalt, and iron in polyterephthalic acid solution
Determination of Ni, Co, and Fe in a PTA solution containing HCl.
- AN-H-129Determination of weak bases in nonaqueous media through catalyzed thermometric endpoint titration (CETT)
Weak, organic bases that are soluble in nonaqueous solvents (including nonpolar solvents) are determined in glacial acetic acid using titration with strong acids, e. g., anhydrous perchloric acid or trifluoromethanesulfonic acid. The endpoint of such titrations can be determined thermometrically, insofar as a suitable thermometric endpoint indicator exists. The exceptional suitability of isobutyl vinyl ether (IBVE) as indicator has been demonstrated.
- AN-V-002Chromium, manganese, and titanium in polyterephthalic acid solution
Determination of Cr, Mn, and Ti in a PTA solution containing HCl.
- 8.000.6057Simultaneous determination of gamma-hydroxybutyric acid (GHB) and gamma-butyrolactone (GBL) in beverages
Psychoactive gamma-hydroxybutyrate (GHB) and its prodrug gamma-butyrolactone (GBL) are substances that are increasingly abused as date-rape and recreational (party) drugs. Since the non-controlled GBL converts into the illicit GHB both in-vivo and in-vitro, their legal distinction is of crucial importance.For the forensic determination of illegally added GHB and GBL in commonly consumed beverages, this work presents a simple and sensitive method that employs direct-injection ion chromatography combined with spectrophotometric detection. The method allows to trace GHB-GLB interconversion, whether in vivo or in vitro lactone cleavage or intramolecular GHB esterification, and thus complies with pertinent requirements of law enforcement agencies.
- AN-T-195Determination of nitrogen content
Kjeldahl method is used to determine the nitrogen content in organic and inorganic samples. Kjeldahl consists of three steps: digestion, distillation, and titration. During the catalytic digestion step, organic nitrogen is converted into ammonium. Sodium hydroxide is added just before the distillation step for converting ammonium into ammonia. Through steam distillation the latter is transferred into the receiver vessel containing an absorbing agent (e.g., boric acid). Finally, the separated ammonia is titrated against sulfuric acid. Protein content in samples can also be determined from the nitrogen content obtained by Kjeldahl setup. USP describes the titration method to determine nitrogen content in organic products using Kjeldahl nitrogen setup. This Application Note illustrates nitrogen determination in heparin sodium.
- AN-SEC-003UV-Vis spectroelectrochemical cell for conventional electrodes
The development of a novel reflection cell for conventional electrodes facilitates the performance of spectroelectrochemical measurements. This device allows researchers to work in aqueous solutions as well as in organic media due to its chemical resistance.
- AN-M-015Trace haloacetic acids, dalapon, and bromate measurement in drinking water
Chlorinating drinking water can form carcinogenic byproducts. EPA Method 557 enables µg/L-level quantification of haloacetic acids using Metrohm IC-MS/MS technology.
- AN-H-100Determination of total acids in highly acidic etch solutions
Determination of the total acids concentration in mixtures of nitric-hydrofluoric acid intended for etching silicon substrates.
- AB-225Simple wine analysis
The Bulletin describes the determination of the following parameters in wine: pH value, total titratable acid, free sulfurous acid, total sulfurous acid as well as ascorbic acid (vitamin C) and other reductones.
- AN-T-237Determination of phosphoric acid with sodium hydroxide
Phosphoric acid is a triprotic inorganic acid used for many purposes: as a raw material for the production of phosphate fertilizers, detergents, as an electrolyte in phosphoric acid fuel cells, rust removers, and for the passivation of iron and zinc to protect against corrosion. This Application Note presents an acid-base titration where the concentration of phosphoric acid is determined over all three of its dissociable protons by titrating it with sodium hydroxide.
- AN-O-019Comparison of suppressed and non-suppressed detection in ion-exclusion chromatography
Determination of glycolic acid, formic acid, glutaric acid, acetic acid, propionic acid, and butyric acid in a standard solution using ion-exclusion chromatography with suppressed and non-suppressed conductivity detection.
- AN-T-236Determination of hydrochloric acid with sodium hydroxide
Hydrochloric acid is a strong, inorganic mineral acid with great significance in the chemical industry. The potentiometric titration of hydrochloric acid with sodium hydroxide is one of the most important and also most frequent analyses performed in the laboratory. In this Application Note, an acid-base titration is presented where the concentration of HCl is determined with NaOH using a pH electrode with an integrated Pt1000 temperature senor for the most accurate results
- 8.000.6071Trace-level determination of anions in the primary circuit of a PWR-type nuclear power plant using ion chromatography after inline sample preparation
The poster presents the ion chromatographic determination of organic degradation products such as glycolate, formate and acetate besides the standard anions fluoride, chloride, nitrate and sulfate.
- AN-H-114Determination of sulfuric acid, nitric acid, and hydrofluoric acid in etch solutions
Two separate titration sequences are required to analyze the mixture:- titration of the HF content with Al(NO3)3 (the «elpasolite» reaction)- titration of the H2SO4 with BaCl2 followed by titration with NaOH to determine the «total acids» contentThe HF, H2SO4, and «total acids» contents are converted to a HNO3 equivalent, with the HNO3 content found by subtracting the HF and H2SO4 from the «total acids» content.
- AN-H-028Standardization of 0.1 mol/L KOH in propan-2-ol
Standardization of 0.1 mol/L in propan-2-ol for use in applications for the determination of weakly acidic species in non-aqueous media.
- AN-O-047Sorbate and benzoate in flavored water applying ion-exclusion chromatography with inverse suppression
Sorbic acid and benzoic acid and their salts are used as food preservatives (E200, E201, E201, E203 and E210, E211, E212, E213 respectively). The content of such preservatives in flavored bottled water may easily be analyzed by ion exclusion chromatography. This method determines the concentration of the respective acid and does not allow differentiating between the counter cations. The determination of sorbic acids and benzoic acid is achieved by conductivity detection after inverse suppression.
- AN-S-337Terephthalate, isophthalate and 5-sulfoisophthalate on the Metrosep A Supp 15 - 50/4.0 using Inline-Partial-Loop Technique
Aromatic dicarboxylic acids, e.g., terephthalate, isophthalate and 5-sulfoisophthalate, are important monomers in the manufacture of polyesters and alkyd resins. The monomer ratio of the dicarboxylic acids has an enormous influence on polymerization. The separation of the late-eluting components is completed within 15 minutes if a short Metrosep A Supp 15 - 50/4.0 type column is used together with high eluent concentrations and flow rates.
- AN-S-151Anions in a cleaning solution
Determination of bromoacetate, methanesulfonate, chloride, phosphate, and sulfate in an acidic cleaning solution using anion chromatography with conductivity detection and chemical suppression.
- AN-PAN-1067Online analysis of organic additives in copper plating process
Monitoring organic additives in copper plating baths is crucial. The 2060 CVS Process Analyzer optimizes copper electroplating by providing precise bath control.
- AN-T-045Acetate, chloride, and phosphate in an infusion solution
Determination of acetate, chloride, and phosphate in an infusion solution by potentiometric titration with sodium hydroxide after conversion of the anions to the corresponding acids.
- AN-H-015Determination of acetic anhydride in acylation mixtures
Determination of acetic anhydride in the presence of acetic acid in acylation mixtures.
- AB-089Potentiometric analysis of anodizing baths
This Bulletin describes potentiometric titration methods for checking sulfuric acid and chromic acid anodizing baths. In addition to the main components aluminum, sulfuric acid, and chromic acid, chloride, oxalic acid, and sulfate are determined.
- AN-PAN-1013Online analysis of boric acid in the cooling water of pressurized water reactors
Boric acid requires precise monitoring in the primary circuit to control nuclear reactor reactivity. The 2060 TI Process Analyzer monitors boric acid online in near-real time.
- AN-H-118Determination of hydrochloric acid in acidic solutions containing iron and aluminum
The presence of the hydrated ion [Fe(H2O)6]3+ can interfere with the determination of «free acid» due to the low pKa value (~2.2) of this ion. Ions of metals such as Fe, Cu, and Al can be masked effectively with fluoride, and permit the determination of the acid content by thermometric alkalimetric titration with good accuracy and precision.
- AN-T-087Carboxyl end groups in polymers – Photometric determination based on ASTM D7409
The carboxyl end groups (CEG) in polymers, such as polyethylene terephthalate (PET), are a measure of the number of unreacted carboxylic acid groups at each end of a polymer chain. The number of CEGs may influence the hydrolysis resistance of geosynthetics, such as geogrids and geotextiles. The lower the CEG value the higher is the hydrolysis resistance of geosynthetics, which in turn increases their stability.This Application Note describes the photometric titration of carboxyl end groups in PET pellets using the Metrohm Optrode. The acidic end groups of the polymer are titrated with an ethanolic KOH solution using bromophenol blue as indicator.
- AN-H-139Determination of nitric acid, hydrofluoric acid and hexafluorosilic acid in simulated etching baths using thermometric titration
Following the addition of caustic soda, hexafluorosilic acid can be determined through back titration of excess hydroxide with hydrochloric acid. Hydrofluoric acid (hydrogen fluoride) is determined by precipitation with aluminum in the presence of sodium and potassium ions. Nitric acid is determined by subtracting the equivalence concentrations of hexafluorosilic acid and hydrofluoric acid from the total acid concentration.
- AN-H-109Determination of sulfuric acid, hydrofluoric acid, and ammonium bifluoride in acid mixtures
Results from three separate single endpoint titrations are used to calculate the results. The mixture of H2SO4, HF, and NH4F/HF contains H+ from H2SO4, HF, and NH4F/HF, SO42- from H2SO4, and F- from HF and NH4F/HF. Analysis of total H+ («total acids») by NaOH titration, F- by titrating with Al(NO3)3 («total fluoride») and SO42- by titrating with BaCl2 provides the information required to determine the composition of the mixture.
- AN-SEC-001Spectroelectrochemistry: an autovalidated analytical technique
Spectroelectrochemical experiments not only provide outstanding qualitative information about samples, but also offer other quantitative data that can be considered when performing analyses. A single set of experiments allows analysts to obtain two calibration curves: one with the electrochemical data and another with the spectroscopic information. The concentration of tested samples is calculated by using both curves, confirming the obtained results by two different routes. In this Application Note, comparison between electrochemical and spectroscopic determinations demonstrates that the two methods measure uric acid (UA) indistinctively, with close agreement of the calculated values with empirical data.
- AN-T-086Vitamin C in orange juice
Vitamin C, also known as ascorbic acid or L-ascorbic acid, is an essential nutrient involved in the repair of tissues and the enzymatic production of certain neurotransmitters. It is required for the functioning of several enzymes and immune performance, and is also an important antioxidant. This nutrient is found in many foods and is often used as a dietary supplement.This Application Note describes the photometric determination of ascorbic acid according to the standard ISO 6557-2. To increase the objectivity on the determined equivalence point and the reproducibility of the results, an autotitrator equipped with a photometric sensor, the Optrode, is used. The titrant 2,6-Dichlorophenol-indophenol (DCIP or DPIP) simultaneously serves as titrant and indicator.
- AN-H-136Determination of hydrochloric acid and nitric acid in etching baths using thermometric titration
Thermometric titration is used for the determination of hydrochloric acid and nitric acid in acid baths. The entire acid content is titrated with caustic soda in the initial titration; the hydrochloric acid content is then determined in a second titration using silver nitrate solution.
- AN-H-038Determination of sulfate and total acids in a nitrating mixture
Determination of sulfate and total acids in a nitrating mixture.
- AN-T-219pH value and TTA in flour, dough, and bread
In order to consistently manufacture high quality baked goods, it is critical to measure the pH value and acidity content in the raw materials and during the production steps. These factors have a major influence on the taste and storage lifetime of the final product. Consistent product quality is only possible with precise measurements during the process.This Application Note describes the measurement of pH value and the total titratable acidity in flour, dough, and bread using the Eco Titrator from Metrohm.
- AN-NIR-023Quality Control of PET
Determination of the diethylene glycol content, isophthalic acid content, intrinsic viscosity (ASTM D4603), and the acid number (AN) of polyethylene terephthalate (PET) is a lengthy and challenging process due to the sample’s limited solubility and the need to use different analytical methods. This application note demonstrates that the DS2500 Solid Analyzer operating in the visible and near-infrared spectral region (Vis-NIR) provides a cost-efficient and fast solution for a simultaneous determination of these parameters in PET. Vis-NIR spectroscopy allows for the analysis of PET in less than one minute without sample preparation or using any chemical reagents.
- AB-068Potentiometric determination of carboxyl and amino terminal groups in polyamide fibers
Indication of the titration endpoint of the weakly alkaline or weakly acidic terminal groups in non-aqueous solution is frequently not easy. An improvement is possible by using a suitable titrant (TBAH = tetrabutylammonium hydroxide for terminal carboxyl groups; perchloric acid for terminal amino groups).An improvement in the evaluation can also be achieved by choosing benzyl alcohol as the solvent.The choice of electrode combination and the measuring setup is also important. Differential potentiometry using the three-electrode technique results in a great improvement in titrations in poorly conducting solutions. Noisy signals are eliminated.
- AN-H-084Determination of mixtures of sulfuric, phosphoric, and nitric acids
Determination of mixtures of sulfuric, phosphoric, and nitric acids. The procedure is suitable for automated analysis using an 814 Sample Processor.
- AB-443Determination of Glycerin Purity by Potentiometric Titration
This method is applicable to all samples containing glycerin in the absence of other triols or other compounds that react with periodate to produce acidic products. Glycerin may be determined in the presence of glycols. A periodate solution reacts slowly with diols and triols in acidic aqueous media at room temperature. A quantitative amount of formic acid is generated from the reaction with glycerin (a triol). The reaction with diols produces neutral aldehydes. The amount of formic acid generated by this reaction is determined by titration against sodium hydroxide.
- AN-H-135Determination of hydrochloric acid and phosphoric acid in etching baths using thermometric titration
Thermometric titration is used for the determination of hydrochloric acid and phosphoric acid in acid mixtures. Two endpoints appear on the titration curve that are used for the determination of the two acids.
- AN-H-119Determination of ferric ion in acidic solutions
This Application Note deals with the determination of ferric ion in acidic and copper-free solutions using thermometric titration. The ferric ion is reduced by iodide. The released iodine reacts exothermically when titrated with thiosulfate solution. The endpoint is determined through temperature plotting by the temperature sensor Thermoprobe.
- AN-H-134Determination of sulfuric acid and phosphoric acid in etching baths using thermometric titration
Thermometric titration can be used for the ready determination of sulfuric acid and phosphoric acid in acid mixtures. An endpoint for each acid appears on the titration curve that can be used to quantify the respective acid.
- AN-NIR-090Quality Control of Mixed Phosphoric, Sulfuric, Nitric, and Hydrofluoric Acids
Fast and reliable detection of phosphoric, sulfuric, nitric, and hydrofluoric acids with near-infrared spectroscopy in under one minute.
- AN-H-101Determination of the water content of mineral acids
A sample of concentrated mineral acid is dissolved in anhydrous acetonitrile, and the water content titrated with a solution of TEOF in acetonitrile. The TEOF reacts exothermically with water in the presence of a strong acid (acting as a catalyst).
- AN-T-247Photometric titration of acid value in biodiesel according to EN 14104
The acid value of fatty acid methyl esters (FAME) like biodiesel can be determined according to EN 14104 using photometric titration with OMNIS and the Optrode.
- AN-T-169Determination of citrate in detergents in accordance with ASTM D4608
Citrate is used in detergents as a water softener for the prevention of lime deposits. The citrate or citric acid content is therefore an important parameter for the quality control of detergents that can be determined conveniently and precisely using titration with copper sulfate.
- AN-S-327Shorter citrate retention times in beverages analysis via step gradient
Strong citrate retention delays chromatographic anion determination in beverages containing citric acid. The use of a step gradient reduces the retention time of the citrate, thus considerably shortening the analysis period.
- AN-PAN-1065Inline monitoring of cell cultures with Raman spectroscopy
This Process Application Note presents a method to accurately monitor lactic acid and glucose inside a bioreactor in «real-time» with the 2060 Raman Analyzer from Metrohm Process Analytics.
- AN-NIR-130Multiparameter hops analysis by near-infrared spectroscopy (NIRS)
NIRS can simultaneously measure several quality parameters in hops like cohumulone, hop oils, and moisture content, the hop storage index (HSI), and alpha and beta acids.
- AN-S-359Anions in N,N-dimethylglycine sodium salt applying a Dose-in Gradient
N,N-dimethylglycine is an amino acid derivative found in plants and animals. The respective sodium salt is available as nutritional supplement. In this context it is expected to have athletic performance enhancer effects and acts against fatigue. It is also accepted as a poultry feed addition. The determination is performed applying a Dose-in Gradient with subsequent conductivity detection after sequential suppression. To enhance the selectivity of the separation, a combination of a Metrosep A Supp 7 - 250/4.0 and a Metrosep A Supp 16 Guard/4.0 was used.
- AN-T-212FOS/TAC in fermentation substrate – Reliable determination for the monitoring of biogas plants
The FOS/TAC value, sometimes referred to as VFA/TA, is a meaningful parameter for assessing both the current condition and the development of anaerobic digestion processes in a digester of a biogas plant. Knowledge of this value can help decrease the risk of acidification problems, which can result in a costly crash of the entire digestion process. Therefore, an accurate and reliable determination of the FOS/TAC value is important for both efficient and cost-effective production operations. This value is determined by an acid-base titration. Using the Eco Titrator from Metrohm equipped with an Ecotrode plus electrode, a reproducible and accurate determination of the FOS/TAC value is possible.
- AN-PAN-1019Online analysis of acids and iron in pickling baths
Pickling baths are used in the galvanic industry to clean steel surfaces and prevent corrosion through passivation. Maintaining specific Fe2+/Fe3+ and free acid/total acid ratios is vital to ensure the baths' optimal performance, which directly impacts the final product quality and reduces production costs by minimizing reagent consumption. This application presents a method to regularly monitor the acid and iron composition in pickling baths online by using a process analyzer from Metrohm Process Analytics.
- AN-S-051Chloride, sulfate, chromate, and sulfonic acids in a chromium plating bath
Determination of chloride, sulfate, chromate, methanesulfonic acid (MSA), methanedisulfonic acid (MDSA), and ethanedisulfonic acid (EDSA) in a chromium plating bath using anion chromatography with conductivity detection after chemical suppression.
- AN-S-389Heat-stable salts in monoethanolamine (MEA) for gas sweetening
In the petrochemical industry, natural gas is processed to remove contaminants and meet product specifications. Process contaminants include acidic gases such as hydrogen sulfide and carbon dioxide, which can corrode costly refinery equipment downstream. Typically, the acidic gases are removed via alkanolamine treatment using monoethanolamine (MEA) or methyldiethanolamine (MDEA). The amine solutions absorb the acidic gases, and then the amine compounds are removed from the natural gas. In addition to the acidic gases, heat stable salts (HSS) that remain in the natural gas are also corrosive to the treatment plants. These are also removed via gas sweetening and need to be determined in the used gas sweetening amine solution. Some typical heat stable salts of interest include acetate (1), formate (2), chloride (3), phosphate (4), sulfate (5), oxalate (6), thiosulfate (7), and thiocyanate (8).
- AN-H-128Determination of ferrous ion in acidic solutions with permanganate as titrant
This Application Note looks at the determination of ferrous ion in acidic solutions through redox titration with potassium permanganate as titrant and thermometric titration.
- AN-H-138Determination of nitric acid and hydrofluoric acid in etching baths using thermometric titration
Thermometric titration is used to determine hydrofluoric acid and nitric acid in etching baths containing ethanol and acetonitrile. Two endpoints appear on the titration curve that are used individually for the quantification of the respective acid.
- AN-H-079Determination of free acid in heat exchanger cleaning acid
Determination of free acid in sulfuric acid («acid shot») solutions employed in the removal of silicate scale in heat exchangers. This method is suitable for acid shot solutions where the silicic acid content is so high that the solutions have gelled.
- AN-H-137Determination of hydrochloric acid and hydrofluoric acid in etching baths using thermometric titration
Thermometric titration is used to determine hydrochloric acid and hydrofluoric acid (hydrogen fluoride) in etching baths containing ethanol and acetonitrile. Two endpoints appear on the titration curve that are used individually for the quantification of the respective acid.
- AN-H-121Determination of ferrous ion in acidic solutions with ceric solution
This Application Note looks at the determination of ferrous ion in acidic solutions from approximately 0.25 g/L by thermometric titration with ceric titrant. The exothermic oxidation reaction shows a sharp endpoint that is detected using the Thermoprobe as a sensitive temperature sensor.
- AN-H-120Determination of aluminum ion in acidic solutions containing ferric and ferrous ions
This Application Note describes the determination of aluminum ion down to approximately 0.5 g/L in acidic solutions containing ferric, ferrous, and other ions whose hydroxides do not dissolve in strongly basic solutions.
- AN-EC-035Using a portable standalone system for easy fermentation monitoring
By using an enzymatic sensor with a screen-printed electrode, producers can measure lactic acid production, thereby monitoring fermentation processes.
- AN-T-223Analysis of electroplating baths
Electroplating processes are used in several different industry sectors to protect the surface quality of various products against corrosion or abrasion and significantly improve their working life. It is essential to check the bath composition on a regular basis to ensure that the process is operating correctly. Typical examples of electroplating baths include alkaline degreasing baths or acidic or alkaline baths containing metals e.g. copper, nickel, or chromium, or components like chloride and cyanide. It is crucial that the chosen analysis technique fulfills high safety standards for these kinds of analyses and produces reliable results. The OMNIS Sample Robot system automatically pipettes and analyzes aggressive electroplating bath samples on different workstations, increasing the safety in the lab. This provides more reliable results in comparison to manual titration and is more time efficient as different parameters can be analyzed in parallel.
- AN-T-227Determination of sodium lactate
Sodium lactate is a salt form of lactic acid used in many regulated industries—therefore an accurate determination of the lactate content is required and is already covered in several norms. One such monograph by the US Pharmacopoeia (USP) results in high accuracies and well-defined titration curves but uses titrants and solvents that are more costly than necessary. In comparison, the presented modified method from Metrohm requires a 1:1 mixture of water and acetone and uses aqueous hydrochloric acid as titrant, resulting in an estimated cost reduction of 40% per titration compared to the USP method (USP–NF 2021, Issue 2). Furthermore, the time needed for each analysis is reduced to just 12% of the USP method (excluding blank determination). This Application Note presents both methods to determine lactate content and shows the results obtained on an OMNIS system.
- AB-039Potentiometric determination of nitrating acid
A potentiometric, nonaqueous method is described for analyzing nitrating acid using cyclohexylamine as titrant. Both sulfuric and nitric acid can be determined quantitatively.
- AB-195Titrimetric determination of free boric acid and tetrafluoroboric acid in nickel plating baths
This Bulletin describes the simultaneous potentiometric titration of free boric acid and free tetrafluoroboric acid in nickel plating baths. After addition of mannitol, the formed mannitol complexes are titrated with sodium hydroxide solution. The determination is carried out directly in the plating bath sample; nickel and other metal ions do not interfere.
- AN-RS-012Handheld Raman for Acid Attack Prevention
Acid throwing, a historical method for retribution against women, has become a modern threat of a different nature. Concentrated acids and other corrosive substances have emerged as modern tools of social violence. Aggressors use common plastic containers with openings that create a powerful directional spray, such as lemon juice squeeze bottles. Sulfuric and phosphoric acids were chosen for analysis here due to their highly corrosive nature- acid attacks in London most commonly use sulfuric, phosphoric, and nitric acids.2017 saw a remarkable number of acid attacks in the UK, with reported incidences averaging 2x a day. Detection and regulation of acids may contribute to prevention of this social scourge.
- 8.000.6013Analysis of produced water contaminants by ion chromatography
The analytical challenge treated by the present work consists in detecting sub-ppm quantities of bromide, sulfate, aliphatic monocarboxylic acids and several alkaline earth metals in the presence of very high concentrations of sodium and chloride. Bromide, sulfate, acetate and butyrate can be reliably determined by suppressed conductivity detection. Due to matrix effects, propionate can only be detected qualitatively. This drawback can be overcome by coupling the ion chromatograph (IC) to a mass spectrometric (MS) detector. This results in reduced matrix interferences and significantly enhanced sensitivities. The cations magnesium, barium and strontium are determined by non-suppressed conductivity detection.
- AN-H-087Determination of hydrofluoric acid by aluminum titration
Determination of hydrofluoric acid in mixed acid etchant solutions.
- AN-Q-006Online analysis of trace anions in borated water of a pressurized water reactor (PWR)
Water of the primary cycle of pressurized water reactors (PWR) contains boron for neutron absorption. The high borate content interferes with the direct analysis of trace anions. Inline Neutralization combined with variable preconcentration and Inline Matrix Elimination (MiPCT-ME) allows to remove boron as boric acid before injection.
- AN-T-034Hydrofluoric and nitric acid in etching baths
Determination of hydrofluoric and nitric acid in etching baths by potentiometric titration.a) Determination of the total acid content using the combined Sb electrode and NaOH as titrant.b) Determination of hydrofluoric acid using the F-ISE and the titrant La(NO3)3.The concentration of nitric acid is then determined by calculation.
- AN-H-116Determination of sulfate in phosphoric acid through the standard addition of sulfuric acid
This Application Note supplements AN-H-003 with the treatment of the standard addition of sulfate as sulfuric acid. This technique may be contemplated when either sulfate levels are too low for a satisfactory direct titration, or when the sample matrix hinders endpoint detection, leading to poor precision and accuracy.
- AN-H-140Titration of phosphoric, nitric, and acetic acid mixtures
Nitric acid, phosphoric acid, and acetic acid are easily determined in etching baths using thermometric titration (TET). Compared to potentiometric titration, TET is faster and more convenient. Analysis is complete in less than two minutes.
- AN-H-089Automated analysis of hexafluorosilicic acid
Automated determination of the H2SiF6 and HF contents of industrial grade hexafluorosilicic acid.
- AB-066Potentiometric and thermometric determination of boric acid
Boric acid is used in many primary circuits of nuclear power plants, in nickel plating baths, and in the production of optical glasses. Furthermore, boron compounds are found in washing powders and fertilizers. This bulletin describes the potentiometric and thermometric determination of boric acid. The determination also covers further boron compounds, when acidic digestion is applied.
- AN-S-114Sulfate in methanesulfonic acid
Determination of sulfate in methansulfonic acid (70%) using anion chromatography with conductivity detection after chemical suppression.
- AN-H-081Determination of phosphoric and nitric acid in nitrophos liquors
Determination of phosphoric and nitric acids in liquors from the Nitrophos fertilizer manufacturing process.
- AN-H-016Determination of acetic, phosphoric, and nitric acid mixtures
Determination of mixtures of phosphoric, nitric, and acetic acids used in etching aluminum in the manufacture of semiconductor devices.
- AB-404Total acid number titration of petroleum products
The determination of the acid number plays a significant role in the analysis of petroleum products. This is manifested in the numerous standard procedures in use over the world (internal specifications of multinational companies, national and international specifications of ASTM, DIN, IP, ISO, etc.). These procedures differ mainly in the composition of the used solvents and titrants.This bulletin describes the determination of the acid number in petroleum products by applying different types of titration.The potentiometric determination is described according to ASTM D664, the photometric according to ASTM D974 and the thermometric titration according to ASTM D8045.
- AN-T-021Sn(II) and sulfuric acid in a tin plating bath
Determination of Sn(II) and sulfuric acid in an acidic tin plating bath by potentiometric titration.
- AN-S-343Heat-stable salts in an MDEA scrubber solution
Hydrogen sulfide (H2S) and carbon dioxide (CO2) are disruptive byproducts of natural gas that must be eliminated during conveyance. This is accomplished with the aid of gas scrubbing, during which the gas flow is cleaned with absorbers such as alkanolamines or akylalkanolamines (e.g., methyldiethanolamine, MDEA). Reliable analysis is imperative, given that heat-stable salts often accumulate in the absorber and thus inhibit the absorption capacity for acid gases.The determination of heat-stable salts (SCN–, S2O32–, SO32–, SO42–, etc.) in MDEA solutions takes place on the Metrosep A Supp 5 - 250/4.0 column with conductivity detection following sequential suppression.Key words: amine gas treating, scrubber
- AN-V-098Molybdenum in sulfuric acid
Mo is determined by polarography at the SMDE in nitric acid solution.
- AN-H-003Determination of sulfate in phosphoric acid
Determination of the sulfate content of wet process phosphoric acid.
- AN-H-093Determination of boric acid by fluoride titration
Determination of boric acid in electroless plating solutions.
- AN-S-053Four anions in boric acid
Determination of fluoride, chloride, phosphate, and sulfate in boric acid using anion chromatography with conductivity detection after chemical suppression.
- AN-S-145Chloride and sulfate in hypophosphoric acid
Determination of chloride and sulfate in hypophosphoric acid using anion chromatography with conductivity detection after chemical suppression.
- AN-V-129Iron (total) in phosphoric acid
The concentration of Fe is determined polarographically in phosphoric acid. The method is suitable for iron in concentrations in the ppm range. Fe(II) and Fe(III) show signals with the same sensitivity
- AN-H-004Determination of fluoride by boric acid titration
This Application Note explains how fluoride determination in acid etching baths can be performed with thermometric titration.
- AN-C-038Five cations in 4% boric acid
Determination of sodium, ammonium, potassium, calcium, and magnesium in 4% boric acid using cation chromatography with direct conductivity detection.
- AN-S-153Chloride in 65% nitric acid using column switching
Determination of chloride in concentrated nitric acid using anion chromatography with conductivity detection and chemical suppression.
- AN-S-392Sulfamic acid besides hydramine and other anions in chemical solutions
Sulfamic acid is a reasonably strong acid, used in descaling agents and for cleaning of dairy and brewing equipment. Here, a chemical solution is analyzed for sulfamate, chloride, nitrite, nitrate, and sulfate. As the solution can also contain hydramine, sufficient separation from the ions of interest is required.
- AN-PAN-1008Online analysis of sulfuric acid in the cumene process (phenol production)
Phenol is a key chemical intermediate used to manufacture polymers, synthetic fibers, resins, detergents, herbicides, and pharmaceuticals. Most phenol production relies on the cumene hydroperoxide route, in which acid cleavage generates phenol and acetone. This Process Application Note describes the online potentiometric titration of sulfuric acid using the 2060 TI EX Proof Process Analyzer to maintain tight process control, enhance phenol quality, and reduce chemical consumption.
- AN-S-066Trace anions in boric acid after preconcentration
Determination of fluoride, chloride, nitrate, phosphate, and sulfate in boric acid with sample preconcentration using anion chromatography with conductivity detection after chemical suppression.
- AN-S-273Fluoride, chloride, and nitrate in concentrated sulfuric acid
Determination of fluoride, chloride, and nitrate in concentrated sulfuric acid (96…98%) using anion chromatography with conductivity detection after sequential suppression.
- AN-C-131Magnesium, cadmium, and iron in phosphoric acid
Determination of magnesium, cadmium, and iron in phosphoric acid using cation chromatography with direct conductivity detection.
- WP-071Improving the corn to ethanol fermentation process with near-infrared spectroscopy (NIRS)
The fermentation of corn starch to produce ethanol is a complex biochemical process that requires monitoring of many different parameters (e.g., solids, pH, sugar profile, glycerol, lactic and acetic acid, and water and ethanol content). Traditional laboratory analysis using primary methods (e.g. Karl Fischer titration) takes about an hour to complete and is a limiting step for increasing plant capacity and efficiency. As a fast and non-destructive analytical technique, near-infrared spectroscopy (NIRS) can replace routine laboratory analysis, decreasing operating costs and increasing plant efficiency and capacity. This White Paper describes the capabilities of the modern analytical method near-infrared (NIR) spectroscopy for monitoring and improving the fermentation process of corn to ethanol.
- AN-PAN-1018Online analysis of acids, bases, and aluminum in anodizing baths
Anodizing metal surfaces improves resistance against corrosion and wear. Etching baths can be monitored precisely online with the 2060 TI Process Analyzer or 2026 HD Titrolyzer.
- AB-316Determination of phosphoric acid in liquid fertilizer with thermometric titration
The phosphoric acid content can be easily titrated with a standardized solution of 2 mol/L NaOH. The interfering calcium content in phosphoric fertilizer can be eliminated by adding a saturated oxalate solution.
- AN-PAN-1010Online analysis of sulfuric acid and zinc sulfate in the viscose process
Monitoring sulfuric acid and zinc sulfate in the viscose wet-spinning process is essential. Online potentiometric titration and colorimetric analysis are recommended for this purpose.
- AN-S-185Phosphoric acid in soft drinks using 761 SD Compact IC
Determination of phosphoric acid in a soft drink using anion chromatography with conductivity detection after chemical suppression.
- AN-U-046Aluminum in an acid extract using UV/VIS detection after post-column reaction with Tiron
Determination of aluminum in an acidic extract containing metals (e.g., alkali, alkaline earth, iron, chromium, molybdenum, etc.) using cation chromatography with UV detection after post-column reaction with Tiron.
- AN-V-028Zinc, cadmium, lead, nickel, and cobalt in hydrochloric acid
Determination of Zn, Cd, Pb, Ni, and Co in hydrochloric acid (37.8%).