Ion-selective electrode, Pb
6.0502.170
Ion-selective electrode, Pb
en
6.0502.170
Feature overview
Lead-selective electrode with crystal membrane.
This ISE has to be used in combination with a reference electrode and is suitable for:
- ion measurements of Pb2+ (10-6 to 0.1 mol/L)
- ion measurements in small sample volumes (minimum immersion depth 1 mm)
- titrations (e.g., sulfate determination with lead nitrate)
Thanks to the robust/break-proof plastic shaft made of EP, this sensor is mechanically very resistant.
The polishing set supplied enables easy cleaning and renewing of the electrode surface.
Tech specs
| Shaft material | EP |
|---|---|
| Measuring range (theoretical) | 1x10-6 ... 0.1 |
| Measuring unit | mol/L |
| Temperature range, long-term (°C) | 0 ... 80 |
| Temperature range, short-term (°C) | 0 ... 80 |
| pH range | 4 ... 7 |
| Indicator electrode shape | Flat |
| Max. installation length (mm) | 123 |
| SGJ sleeve | Flexible SGJ sleeve |
| Shaft diameter top (mm) | 12 |
| Shaft diameter bottom (mm) | 12 |
| Min. immersion depth (mm) | 1 |
| Electrode plug-in head | Metrohm plug-in head G |
| Indicator electrode type | Crystal (Pb) |
-
- Polishing set for solid-state electrodes
- 6.2802.000
- Polishing set with 1 polishing cloth and about 2 g aluminum oxide powder (grain size 0.3 µm)
- Polishing set with 1 polishing cloth and about 2 g aluminum oxide powder (grain size 0.3 µm)
- PCS
- 1
-
- Polishing set for solid-state electrodes
- 6.2802.000
- Polishing set with 1 polishing cloth and about 2 g aluminum oxide powder (grain size 0.3 µm)
- Polishing set with 1 polishing cloth and about 2 g aluminum oxide powder (grain size 0.3 µm)
- PCS
- 1
-
- LL ISE reference electrode
- 6.0750.100
- Silver / silver chloride reference electrode with double junction system.This reference electrode is well suited for:automated applications; ion measurements; surfactant titrations; The ground-joint diaphragm, which is insensitive to contamination, offers a constant and reproducible electrolyte outflow. Additionally, the reference electrolyte is gelified for even better signal stability. The sensor is delivered with c(KCl) = 3 mol/L as bridge electrolyte, which can be freely selected and exchanged as needed.
- <p>Silver / silver chloride reference electrode with double junction system.<br/>This reference electrode is well suited for:</p><ul><li>automated applications</li><li>ion measurements</li><li>surfactant titrations</li></ul><p>The ground-joint diaphragm, which is insensitive to contamination, offers a constant and reproducible electrolyte outflow. Additionally, the reference electrolyte is gelified for even better signal stability. The sensor is delivered with c(KCl) = 3 mol/L as bridge electrolyte, which can be freely selected and exchanged as needed.</p>
- PCS
- 1
- Electrode cable / 1 m / F
- 6.2104.020
- For connecting electrodes with Metrohm plug-in head G to Metrohm instruments (socket F).
- For connecting electrodes with Metrohm plug-in head G to Metrohm instruments (socket F).
- PCS
- 1