Separate Ag-rod electrode
6.0331.010
Separate Ag-rod electrode
en
6.0331.010
Feature overview
This metal electrode has to be used in combination with a reference electrode (c(KNO3) = 1 mol/L as reference electrolyte) and is well suited for precipitation titrations (titrant silver nitrate). The robust shaft made of polypropylene and the metal rod can be replaced separately.
Tech specs
| Shaft material | PP |
|---|---|
| Measuring range (theoretical) | –2000 ... 2000 |
| Measuring unit | mV |
| Temperature range, long-term (°C) | 0 ... 80 |
| Temperature range, short-term (°C) | 0 ... 80 |
| SGJ sleeve | Standard ground-joint 14/15 |
| Min. immersion depth (mm) | 5 |
| Electrode plug-in head | Metrohm socket B negative with cable (l = 1 m) |
| Indicator electrode type | Ag |
| Indicator electrode shape | Pin |
| Indicator electrode type (reference) | - |
-
- Strand / 1 m / 2 x B
- 6.2106.020
- Electrode cable with 2 x plug B (4 mm) for connecting electrodes with plug-in head B
- Electrode cable with 2 x plug B (4 mm) for connecting electrodes with plug-in head B
- PCS
- 1
-
- Strand / 1 m / 2 x B
- 6.2106.020
- Electrode cable with 2 x plug B (4 mm) for connecting electrodes with plug-in head B
- Electrode cable with 2 x plug B (4 mm) for connecting electrodes with plug-in head B
- PCS
- 1
-
- Ag/AgCl reference electrode (length 12.5 cm)
- 6.0729.100
- Silver/silver chloride reference electrode with Double-Junction System and separate shielding, installation length 10 cm.This reference electrode is well-suited for:Nonaqueous samples; Differential potentiometry; The standard ground-joint 14/15 enables easy assembly, and the flexible ground-joint diaphragm, which is insensitive to contamination, can be replaced at any time. The reference electrolyte and the bridge electrolyte can be selected freely according to use, and are easy to replace. The sensor is supplied without electrolyte filling.
- <p>Silver/silver chloride reference electrode with Double-Junction System and separate shielding, installation length 10 cm.<br/>This reference electrode is well-suited for:</p><ul><li>Nonaqueous samples</li><li>Differential potentiometry</li></ul><p>The standard ground-joint 14/15 enables easy assembly, and the flexible ground-joint diaphragm, which is insensitive to contamination, can be replaced at any time. The reference electrolyte and the bridge electrolyte can be selected freely according to use, and are easy to replace. The sensor is supplied without electrolyte filling.</p>
- PCS
- 1
- Electrode shaft
- 6.1241.030
- Electrode shaft for separate metal pin electrodes
- Electrode shaft for separate metal pin electrodes
- PCS
- 1
- Silver Electrode Rod
- 6.1248.010
- Silver Electrode Rod for separate metal pin electrode
- Silver Electrode Rod for separate metal pin electrode
- PCS
- 1