Du er blevet omdirigeret til din lokale version af den anmodede side
CVS electrode equipment with 2 mm platinum electrode for Professional VA/CVS instruments

CVS electrode equipment with 2 mm platinum electrode for Professional VA/CVS instruments

6.5339.010

CVS electrode equipment with 2 mm platinum electrode for Professional VA/CVS instruments

en

6.5339.010

Overblik over funktioner

Complete electrode set for the determination of organic additives in electroplating baths with CVS (Cyclic Voltammetric Stripping). Contains rotating platinum working electrode (electrode diameter: 2 mm), reference electrode, platinum auxiliary electrode, measuring vessels and electrolyte solutions.

    • Separate Pt Rod Electrode
    • 6.0343.100
    • Platinum auxiliary electrode for voltammetry and CVS.
    • <p>Platinum auxiliary electrode for voltammetry and CVS.</p>
    • PCS
    • 1
    • LL-Ag/AgCl reference electrode for CVS
    • 6.0728.130
    • Inner reference system with electrolyte c(KCl) = 3 mol/L. For use with electrolyte vessel made of plastic 6.1245.010.
    • <p>Inner reference system with electrolyte c(KCl) = 3 mol/L. For use with electrolyte vessel made of plastic 6.1245.010.</p>
    • PCS
    • 1
    • Driving axle for rotating disk electrode (RDE)
    • 6.1204.510
    • Driving axle for rotating disk electrode (RDE) with titanium axle for Professional VA/CVS instruments, M3 thread.
    • <p>Driving axle for rotating disk electrode (RDE) with titanium axle for Professional VA/CVS instruments, M3 thread.</p>
    • PCS
    • 1
    • 2 mm platinum electrode tip for CVS
    • 6.1204.610
    • Metal electrode tip made of platinum (Pt), diameter of electrode disk 2 mm ±0.05 mm, polished surface, shaft made of glass, M3 thread connection. Concentricity error: < 0.3 mm. Temperature range: 0 - 50 °C.
    • <p>Metal electrode tip made of platinum (Pt), diameter of electrode disk 2 mm ±0.05 mm, polished surface, shaft made of glass, M3 thread connection. Concentricity error: &lt; 0.3 mm. Temperature range: 0 - 50 °C.</p>
    • PCS
    • 1
    • Electrolyte vessel made of plastic
    • 6.1245.010
    • Electrolyte vessel made of plastic with ceramic diaphragm for double junction reference electrode.
    • <p>Electrolyte vessel made of plastic with ceramic diaphragm for double junction reference electrode.</p>
    • PCS
    • 1
    • Electrolyte 3 mol/L KCl (250 mL)
    • 6.2308.020
    • Electrolyte solution c(KCl) = 3 mol/L, (for Ag/AgCl reference systems)
    • Electrolyte solution c(KCl) = 3 mol/L, (for Ag/AgCl reference systems)
    • PCS
    • 1
    • Electrolyte KNO3-1mol/L 250 mL
    • 6.2310.010
    • Electrolyte solution KNO3 1 M (reference electrolyte for combined silver electrodes)
    • Electrolyte solution KNO<SUB>3</SUB> 1 M (reference electrolyte for combined silver electrodes)
    • PCS
    • 1
    • Separate Pt Rod Electrode
    • 6.0343.100
    • Platinum auxiliary electrode for voltammetry and CVS.
    • <p>Platinum auxiliary electrode for voltammetry and CVS.</p>
    • PCS
    • 1
    • LL-Ag/AgCl reference electrode for CVS
    • 6.0728.130
    • Inner reference system with electrolyte c(KCl) = 3 mol/L. For use with electrolyte vessel made of plastic 6.1245.010.
    • <p>Inner reference system with electrolyte c(KCl) = 3 mol/L. For use with electrolyte vessel made of plastic 6.1245.010.</p>
    • PCS
    • 1
    • Driving axle for rotating disk electrode (RDE)
    • 6.1204.510
    • Driving axle for rotating disk electrode (RDE) with titanium axle for Professional VA/CVS instruments, M3 thread.
    • <p>Driving axle for rotating disk electrode (RDE) with titanium axle for Professional VA/CVS instruments, M3 thread.</p>
    • PCS
    • 1
    • 2 mm platinum electrode tip for CVS
    • 6.1204.610
    • Metal electrode tip made of platinum (Pt), diameter of electrode disk 2 mm ±0.05 mm, polished surface, shaft made of glass, M3 thread connection. Concentricity error: < 0.3 mm. Temperature range: 0 - 50 °C.
    • <p>Metal electrode tip made of platinum (Pt), diameter of electrode disk 2 mm ±0.05 mm, polished surface, shaft made of glass, M3 thread connection. Concentricity error: &lt; 0.3 mm. Temperature range: 0 - 50 °C.</p>
    • PCS
    • 1
    • Electrolyte vessel made of plastic
    • 6.1245.010
    • Electrolyte vessel made of plastic with ceramic diaphragm for double junction reference electrode.
    • <p>Electrolyte vessel made of plastic with ceramic diaphragm for double junction reference electrode.</p>
    • PCS
    • 1
    • Electrolyte 3 mol/L KCl (250 mL)
    • 6.2308.020
    • Electrolyte solution c(KCl) = 3 mol/L, (for Ag/AgCl reference systems)
    • Electrolyte solution c(KCl) = 3 mol/L, (for Ag/AgCl reference systems)
    • PCS
    • 1
    • Electrolyte KNO3-1mol/L 250 mL
    • 6.2310.010
    • Electrolyte solution KNO3 1 M (reference electrolyte for combined silver electrodes)
    • Electrolyte solution KNO<SUB>3</SUB> 1 M (reference electrolyte for combined silver electrodes)
    • PCS
    • 1