Du er blevet omdirigeret til din lokale version af den anmodede side
859 Titrotherm complete with tiamo™

859 Titrotherm complete with tiamo™

2.859.1010

Dette produkt er udgået, men understøttes stadig
Gå til erstatningsprodukt
    • Piston tongs
    • 6.1546.030
    • For pistons for 807 Dosing Units or cylinder units OMNIS.
    • <p>For pistons for 807 Dosing Units or cylinder units OMNIS.</p>
    • PCS
    • 1
    • Stirring propeller / 87 mm
    • 6.1909.010
    • Propeller stirrer, length from lower edge of SGJ: 96 mm. For use with beakers with 722, 802 Rod Stirrer
    • <p>Propeller stirrer, length from lower edge of SGJ: 96 mm. For use with beakers with 722, 802 Rod Stirrer</p>
    • PCS
    • 1
    • Clamping ring
    • 6.2013.010
    • For support rods with a diameter of 10 mm.
    • <p>For support rods with a diameter of 10 mm.</p>
    • PCS
    • 1
    • Support stand with support rod
    • 6.2026.010
    • Complete, with stand rod, total length 42 cm. Used with 649, 728 Magnetic Swing-out Stirrer alone (without Dosimat)
    • <p>Complete, with stand rod, total length 42 cm. Used with 649, 728 Magnetic Swing-out Stirrer alone (without Dosimat)</p>
    • PCS
    • 1
    • Intermediate SGJ sleeve
    • 6.2727.010
    • Used with reference and auxiliary electrodes in measuring and titration vessel with 6.1414.010 lid
    • Used with reference and auxiliary electrodes in measuring and titration vessel with 6.1414.010 lid
    • PCS
    • 1
    • 807 Dosing Unit 10 mL
    • 6.3032.210
    • 807 Dosing Unit with integrated data chip with 10 mL glass cylinder and light protection, mountable to a reagent bottle with ISO/DIN GL 45 glass thread. FEP tubing connection, antidiffusion tip.
    • <p>807 Dosing Unit with integrated data chip with 10 mL glass cylinder and light protection, mountable to a reagent bottle with ISO/DIN GL 45 glass thread. FEP tubing connection, antidiffusion tip.</p>
    • PCS
    • 1
    • Thermoprobe
    • 6.9011.020
    • High-sensitivity temperature sensor for thermometric titration with an 859 Titrotherm.The Thermoprobe has a short response time and a high resolution, which enables the precise recording of even the smallest temperature changes.This sensor can be used in aqueous and non-aqueous solutions which do not contain any HF, for determinations such as: acid number (TAN) in accordance with ASTM D8045; total base number (TBN); free fatty acids; Ca /Mg determination; phosphate;
    • <p>High-sensitivity temperature sensor for thermometric titration with an 859 Titrotherm.<br/>The Thermoprobe has a short response time and a high resolution, which enables the precise recording of even the smallest temperature changes.<br/>This sensor can be used in aqueous and non-aqueous solutions which do not contain any HF, for determinations such as:<br/> </p><ul><li>acid number (TAN) in accordance with ASTM D8045</li><li>total base number (TBN)</li><li>free fatty acids</li><li>Ca /Mg determination</li><li>phosphate</li></ul>
    • PCS
    • 1
    • 800 Dosino (cable length 1.5 m)
    • 1.800.0030
    • Drive with write/read hardware for intelligent dosing units. With permanently attached cable (length 1.5 m).
    • <p>Drive with write/read hardware for intelligent dosing units. With permanently attached cable (length 1.5 m).</p>
    • PCS
    • 1
    • 802 Rod Stirrer for 727 Ti Stand
    • 1.802.0010
    • Rod stirrer with separate 6.2137.000 Speed controller and 6.1909.010 Propeller stirrer.
    • Rod stirrer with separate 6.2137.000 Speed controller and 6.1909.010 Propeller stirrer.
    • PCS
    • 1
    • 804 Ti Stand without stand rod
    • 1.804.0010
    • Titration stand and controller for 802 Stirrer. The 804 Ti Stand together with the optional 802 Stirrer provides an alternative to the magnetic stirrer. Without stand.
    • Titration stand and controller for 802 Stirrer. The 804 Ti Stand together with the optional 802 Stirrer provides an alternative to the magnetic stirrer. Without stand.
    • PCS
    • 1
    • Piston tongs
    • 6.1546.030
    • For pistons for 807 Dosing Units or cylinder units OMNIS.
    • <p>For pistons for 807 Dosing Units or cylinder units OMNIS.</p>
    • PCS
    • 1
    • Stirring propeller / 87 mm
    • 6.1909.010
    • Propeller stirrer, length from lower edge of SGJ: 96 mm. For use with beakers with 722, 802 Rod Stirrer
    • <p>Propeller stirrer, length from lower edge of SGJ: 96 mm. For use with beakers with 722, 802 Rod Stirrer</p>
    • PCS
    • 1
    • Clamping ring
    • 6.2013.010
    • For support rods with a diameter of 10 mm.
    • <p>For support rods with a diameter of 10 mm.</p>
    • PCS
    • 1
    • Support stand with support rod
    • 6.2026.010
    • Complete, with stand rod, total length 42 cm. Used with 649, 728 Magnetic Swing-out Stirrer alone (without Dosimat)
    • <p>Complete, with stand rod, total length 42 cm. Used with 649, 728 Magnetic Swing-out Stirrer alone (without Dosimat)</p>
    • PCS
    • 1
    • Intermediate SGJ sleeve
    • 6.2727.010
    • Used with reference and auxiliary electrodes in measuring and titration vessel with 6.1414.010 lid
    • Used with reference and auxiliary electrodes in measuring and titration vessel with 6.1414.010 lid
    • PCS
    • 1
    • 807 Dosing Unit 10 mL
    • 6.3032.210
    • 807 Dosing Unit with integrated data chip with 10 mL glass cylinder and light protection, mountable to a reagent bottle with ISO/DIN GL 45 glass thread. FEP tubing connection, antidiffusion tip.
    • <p>807 Dosing Unit with integrated data chip with 10 mL glass cylinder and light protection, mountable to a reagent bottle with ISO/DIN GL 45 glass thread. FEP tubing connection, antidiffusion tip.</p>
    • PCS
    • 1
    • Thermoprobe
    • 6.9011.020
    • High-sensitivity temperature sensor for thermometric titration with an 859 Titrotherm.The Thermoprobe has a short response time and a high resolution, which enables the precise recording of even the smallest temperature changes.This sensor can be used in aqueous and non-aqueous solutions which do not contain any HF, for determinations such as: acid number (TAN) in accordance with ASTM D8045; total base number (TBN); free fatty acids; Ca /Mg determination; phosphate;
    • <p>High-sensitivity temperature sensor for thermometric titration with an 859 Titrotherm.<br/>The Thermoprobe has a short response time and a high resolution, which enables the precise recording of even the smallest temperature changes.<br/>This sensor can be used in aqueous and non-aqueous solutions which do not contain any HF, for determinations such as:<br/> </p><ul><li>acid number (TAN) in accordance with ASTM D8045</li><li>total base number (TBN)</li><li>free fatty acids</li><li>Ca /Mg determination</li><li>phosphate</li></ul>
    • PCS
    • 1
    • PFA titration vessel / 10 to 90 mL
    • 6.1450.210
    • For ultratrace analysis and for solutions containing fluoride.
    • For ultratrace analysis and for solutions containing fluoride.
    • PCS
    • 1
    • 807 Dosing Unit ETFE 5 mL
    • 6.1575.150
    • 807 Dosing Unit ETFE 5 mL for dosing alkali reagents or hydrofluoric acid (HF) with Dosinos. Less precision and reproducibility is to be expected in comparison with glass cylinders. 
    • <p>807 Dosing Unit ETFE 5 mL for dosing alkali reagents or hydrofluoric acid (HF) with Dosinos. Less precision and reproducibility is to be expected in comparison with glass cylinders.</p><p> </p>
    • PCS
    • 1
    • Electrode holder with rinsing device
    • 6.2021.030
    • Electrode holder with rinsing device for 4 electrodes and 2 buret tipsConnection for rinsing water, integrated magnetic switch for 722, 802 Stirrer. Used with 727 Ti Stand
    • <p>Electrode holder with rinsing device for 4 electrodes and 2 buret tipsConnection for rinsing water, integrated magnetic switch for 722, 802 Stirrer. Used with 727 Ti Stand</p>
    • PCS
    • 1
    • Bottle holder for Dosinos
    • 6.2061.010
    • Bottle holder for up to two Dosinos, mounted on 1 L reagent bottles.
    • Bottle holder for up to two Dosinos, mounted on 1 L reagent bottles.
    • PCS
    • 1
    • 807 Dosing Unit 2 mL
    • 6.3032.120
    • 807 Dosing Unit with integrated data chip with 2 mL glass cylinder and light protection, mountable to a reagent bottle with ISO/DIN GL 45 glass thread. FEP tubing connection, antidiffusion tip.
    • <p>807 Dosing Unit with integrated data chip with 2 mL glass cylinder and light protection, mountable to a reagent bottle with ISO/DIN GL 45 glass thread. FEP tubing connection, antidiffusion tip.</p>
    • PCS
    • 1
    • 807 Dosing Unit 5 mL
    • 6.3032.150
    • 807 Dosing Unit with integrated data chip with 5 mL glass cylinder and light protection, mountable to a reagent bottle with ISO/DIN GL 45 glass thread. FEP tubing connection, antidiffusion tip.
    • <p>807 Dosing Unit with integrated data chip with 5 mL glass cylinder and light protection, mountable to a reagent bottle with ISO/DIN GL 45 glass thread. FEP tubing connection, antidiffusion tip.</p>
    • PCS
    • 1
    • 807 Dosing Unit 20 mL
    • 6.3032.220
    • 807 Dosing Unit with integrated data chip with 20 mL glass cylinder and light protection, mountable to a reagent bottle with ISO/DIN GL 45 glass thread. FEP tubing connection, antidiffusion tip.
    • <p>807 Dosing Unit with integrated data chip with 20 mL glass cylinder and light protection, mountable to a reagent bottle with ISO/DIN GL 45 glass thread. FEP tubing connection, antidiffusion tip.</p>
    • PCS
    • 1
    • 807 Dosing Unit 50 mL
    • 6.3032.250
    • 807 Dosing Unit with integrated data chip with 50 mL glass cylinder and light protection, mountable to a reagent bottle with ISO/DIN GL 45 glass thread. FEP tubing connection, antidiffusion tip.
    • <p>807 Dosing Unit with integrated data chip with 50 mL glass cylinder and light protection, mountable to a reagent bottle with ISO/DIN GL 45 glass thread. FEP tubing connection, antidiffusion tip.</p>
    • PCS
    • 1
    • Thermoprobe HF
    • 6.9011.040
    • High-sensitivity temperature sensor for thermometric titrations with an 859 Titrotherm in HF-containing media.The Thermoprobe has a short response time and a high resolution, which enables the precise recording of even the smallest temperature changes.This sensor can be used in acidic, fluoride-containing solutions but is not resistant to organic solvents. It is suitable for: the determination of sodium; titration of etching baths;
    • <p>High-sensitivity temperature sensor for thermometric titrations with an 859 Titrotherm in HF-containing media.<br/>The Thermoprobe has a short response time and a high resolution, which enables the precise recording of even the smallest temperature changes.<br/>This sensor can be used in acidic, fluoride-containing solutions but is not resistant to organic solvents. It is suitable for:<br/> </p><ul><li>the determination of sodium</li><li>titration of etching baths</li></ul>
    • PCS
    • 1