Chuyển hướng tin nhắn
Solitrode with Pt1000

Solitrode with Pt1000

6.0228.600

Solitrode with Pt1000

vi

6.0228.600

Tổng quan

Combined pH electrode with integrated Pt1000 temperature sensor.
This electrode is suitable for routine pH measurements in solutions that do not contain precipitates, proteins, or sulfides. This electrode is mechanically resistant thanks to the robust/unbreakable plastic shaft made of polypropylene and impact protection for the glass membrane.
Reference electrolyte: c(KCl) = 3 mol/L, storage in storage solution.

Thông số kỹ thuật

Shaft materialPP
Shaft material (completion)Glass
Measuring range (theoretical)0 ... 14
Measuring unitpH
Temperature range, long-term (°C)0 ... 80
Temperature range, short-term (°C)0 ... 80
Max. installation length (mm)113
SGJ sleeveFlexible SGJ sleeve
Shaft diameter top (mm)12
Shaft diameter bottom (mm)12
Min. immersion depth (mm)15
Electrode plug-in headMetrohm plug-in head U
Temperature sensorPt1000
Indicator electrode typeGlass electrode
Indicator electrode shapeHemisphere
Membrane glass typeT
Membrane resistance200 ... 400
Electrode zero point (mV)± 15
Electrode slope> 0.97
Asymmetry potential± 15
Internal reference electrode typeLL system
DiaphragmCeramic diaphragm
Reference electrolyte typec(KCl) = 3 mol/L
Electrolyte flow rate (μl/h) at 10 cm water column3 ... 10
Reference systemLL system
Resistance (kOhm)<5
Sản phẩm này đã ngừng sản xuất, nhưng vẫn được hỗ trợ.
    • Sleeve with SGJ 14/12 mm
    • 6.1236.050
    • Sleeve with SGJ 14/12 mm, polyethylene.
    • Sleeve with SGJ 14/12 mm, polyethylene.
    • PCS
    • 1
    • Storage vessel 
    • 6.2008.040
    • Together with 6.2008.050 storage vessel holder. it provides a support for the electrode on 807 Dosing Units.
    • <p>Together with 6.2008.050 storage vessel holder. it provides a support for the electrode on 807 Dosing Units.</p>
    • PCS
    • 1
    • Sleeve with SGJ 14/12 mm
    • 6.1236.050
    • Sleeve with SGJ 14/12 mm, polyethylene.
    • Sleeve with SGJ 14/12 mm, polyethylene.
    • PCS
    • 1
    • Storage vessel 
    • 6.2008.040
    • Together with 6.2008.050 storage vessel holder. it provides a support for the electrode on 807 Dosing Units.
    • <p>Together with 6.2008.050 storage vessel holder. it provides a support for the electrode on 807 Dosing Units.</p>
    • PCS
    • 1
    • Electrolyte 3 mol/L KCl (250 mL)
    • 6.2308.020
    • Electrolyte solution c(KCl) = 3 mol/L, (for Ag/AgCl reference systems)
    • Electrolyte solution c(KCl) = 3 mol/L, (for Ag/AgCl reference systems)
    • PCS
    • 1
    • Storage solution
    • 6.2323.000
    • Storage solution for all combined pH glass electrodes with reference electrolyte c(KCl) = 3 mol/L
    • Storage solution for all combined pH glass electrodes with reference electrolyte c(KCl) = 3 mol/L
    • PCS
    • 1
    • pHit kit
    • 6.2325.000
    • Maintenance kit for pH electrodes The kit contains:50 mL cleaning solution; 50 mL 3M KCl solution; 50 mL storage solution; 2 Storage vessels; Instructions for use;
    • <p>Maintenance kit for pH electrodes </p><p>The kit contains:</p><ul><li>50 mL cleaning solution</li><li>50 mL&nbsp;3M KCl solution</li><li>50 mL&nbsp;storage solution</li><li>2 Storage vessels</li><li>Instructions for use</li></ul>
    • PCS
    • 1
    • Cleaning solution 3 x 50 mL
    • 6.2325.100
    • Reliable measuring results over long periods of time can be guaranteed only if the pH glass membrane and the diaphragm receive preventive and regular care. Cleaning by etching with toxic chemicals or applying mechanical treatment to the diaphragm is not only complicated and expensive, it also accelerates the ageing of the pH glass electrode.The cleaning solution was developed for easy and gentle cleaning of pH glass electrodes. Regular use can considerably prolong their service life.This cleaning solution is also part of the pHit kit.
    • <p>Reliable measuring results over long periods of time can be guaranteed only if the pH glass membrane and the diaphragm receive preventive and regular care. Cleaning by etching with toxic chemicals or applying mechanical treatment to the diaphragm is not only complicated and expensive, it also accelerates the ageing of the pH glass electrode.<br/>The cleaning solution was developed for easy and gentle cleaning of pH glass electrodes. Regular use can considerably prolong their service life.<br/><br/>This cleaning solution is also part of the pHit kit.</p>
    • PCS
    • 1