Eco IC

Eco IC
Beställningsnummer: 2.925.0020

Ion chromatography for everyone! The Eco IC is the entry into ion chromatography at a very affordable price. The instrument is particularly suitable for water analysis in routine operations and for training purposes at schools and universities. Included in the scope of delivery are the conductivity detector, the Metrohm Suppressor Module ("MSM") and the software. Later automation for up to 36 samples and the use of Inline Ultrafiltration are possible at any time.

  • Dokument
  • Ingående delar och tillbehör
  • Alternativ

Ladda ner hela leveransomfattningen och extra tillbehör som PDF

  • 
    Bottle attachment / GL 45 - 3 x UNF 10/32
    6.1602.150
    Bottle attachment / GL 45 - 3 x UNF 10/32

    For the connection of 1/16 in. capillaries. Used in conjunction with MSM auxiliary solutions and in Metrohm Inline Sample Preparation.


    1 piece(s)

  • 
            
    Eluent bottle cap GL 45
    6.1602.160
    Eluent bottle cap GL 45
    For eluent bottles, with connectors for the adsorber tube and the aspiration tubing.

    1 piece(s)

  • Glass bottle / 1000 mL / GL 45
    6.1608.020
    Glass bottle / 1000 mL / GL 45

    Bottle for auxiliary solutions.

    1 piece(s)

  • Eluent bottle / 2 L / GL 45
    6.1608.070
    Eluent bottle / 2 L / GL 45

    1 piece(s)

  • Adsorbing tube, large and bent
    6.1609.000
    Adsorbing tube, large and bent
    For filling with adsorber material.

    1 piece(s)

  • PTFE capillary 0.5 mm i.d. / 3 m
    6.1803.030
    PTFE capillary 0.5 mm i.d. / 3 m
    Capillary for inline dialysis, for Dialysis Unit, IC Dialysis Sample Processor, IC Liquid Handling Dialysis Unit

    1 piece(s)

  • PTFE capillary 0.5 mm i.d. / 1 m
    6.1803.040
    PTFE capillary 0.5 mm i.d. / 1 m
    Capillary for sample handling in IC.

    1 piece(s)

  • Y-connector for tubing 6-9 mm i.d.
    6.1807.010
    Y-connector for tubing 6-9 mm i.d.
    Connector for waste tubing

    1 piece(s)

  • Silicone tubing 6 mm i.d., 1 m
    6.1816.020
    Silicone tubing 6 mm i.d., 1 m
    For waste tubing.

    2 piece(s)

  • PharMed® pump tubing (orange/yellow), 3-stopper
    6.1826.420
    PharMed® pump tubing (orange/yellow), 3-stopper

    For MSM regeneration with peristaltic pump.


    1 piece(s)

  • PEEK capillary 0.25 mm i.d., 1 m
    6.1831.100
    PEEK capillary 0.25 mm i.d., 1 m

    1 piece(s)

  • Clip for SGJ 14/15
    6.2023.020
    Clip for SGJ 14/15
    Clip for SGJ 14/16

    1 piece(s)

  • Cable USB A - USB B  1.8 m
    6.2151.020
    Cable USB A - USB B 1.8 m
    USB connecting cable

    1 piece(s)

  • Colored sleeves for capillaries
    6.2251.000
    Colored sleeves for capillaries
    Colored pieces of heat shrink tubing for capillary coding. Three pieces each of five different colors.

    1 piece(s)

  • Tool for piston seal
    6.2617.010
    Tool for piston seal
    For removing and assembling the piston seal for all standard pump heads

    1 piece(s)

  • Adjustable wrench
    6.2621.000
    Adjustable wrench
    Max. opening: 20 mm. For IC instruments

    2 piece(s)

  • Hexagon key 4 mm
    6.2621.030
    Hexagon key 4 mm

    1 piece(s)

  • 1/4 in. wrench
    6.2621.050
    1/4 in. wrench
    For 1/4 in. screws. For IC instruments

    1 piece(s)

  • Capillary cutter
    6.2621.080
    Capillary cutter
    For plastic capillaries. Used with IC instruments

    1 piece(s)

  • 
    3 mm hex key for IC Sample Processors
    6.2621.100
    3 mm hex key for IC Sample Processors

    1 piece(s)

  • Wrench
    6.2739.000
    Wrench
    For tightening connectors

    2 piece(s)

  • Stopper for overflow (ProfIC), 5 pieces
    6.2743.080
    Stopper for overflow (ProfIC), 5 pieces
    For Professional IC instruments

    1 piece(s)

  • Pressure screw 2x
    6.2744.014
    Pressure screw 2x
    With UNF 10/32 connection. For the connection of PEEK capillaries

    1 piece(s)

  • Luer/UNF coupling
    6.2744.020
    Luer/UNF coupling
    For IC instruments

    1 piece(s)

  • Coupling olive/UNF 10/32, 1x
    6.2744.035
    Coupling olive/UNF 10/32, 1x

    Connection between pressure screw and pump tubing. 1 piece. For IC instruments with peristaltic pump.

    1 piece(s)

  • 2 x UNF 10/32 coupling
    6.2744.040
    2 x UNF 10/32 coupling
    For connecting 1/16 in. capillaries. For IC instruments

    3 piece(s)

  • Pressure screw short
    6.2744.070
    Pressure screw short
    Short version. With UNF 10/32 connection. 5 pieces. For the connection of PEEK capillaries

    2 piece(s)

  • Pump tubing connector with security lock and filter
    6.2744.180
    Pump tubing connector with security lock and filter
    For the connection of a pump tubing and a capillary with built-in filter

    1 piece(s)

  • Tubing adaptor for aspiration filter (ProfIC)
    6.2744.210
    Tubing adaptor for aspiration filter (ProfIC)
    For Professional IC instruments

    1 piece(s)

  • Syringe 10 mL with Luer connection
    6.2816.020
    Syringe 10 mL with Luer connection
    For various applications in IC and VA

    1 piece(s)

  • Purge tubing
    6.2816.040
    Purge tubing
    With PTFE tubing and Luer connection. For syringes. For aspirating eluents.

    1 piece(s)

  • Aspiration filter
    6.2821.090
    Aspiration filter
    Pore size 20 µm, set of 5 pieces. For 6.1834.000 Aspiration tubing and 6.1821.040 and 6.1821.050 Filter tubes.

    1 piece(s)

  • Spare filter for inline filter
    6.2821.130
    Spare filter for inline filter
    Spare filter for inline filter.

    1 piece(s)

  • MSM Rotor A
    6.2832.000
    MSM Rotor A
    Suppressor rotor for all IC instruments with MSM (Metrohm Suppressor Module)

    1 piece(s)

  • 
    Connecting piece to MSM and SPM module
    6.2835.010
    Connecting piece to MSM and SPM module

    Universal connecting piece for MSM in Professional IC Vario and Compact Flex instruments and for MSM-HC and SPM module. With inlets and outlets.


    1 piece(s)

  • 
    Adapter sleeve for Suppressor Vario
    6.2842.020
    Adapter sleeve for Suppressor Vario

    The use of the adapter sleeve makes it possible to install both the Standard MSM and the MSM-LC rotor in the MSM-HC housing.


    1 piece(s)

Ladda ner hela leveransomfattningen och extra tillbehör som PDF

  • Metrosep A Supp 17 - 100/4.0
    6.01032.410
    Metrosep A Supp 17 - 100/4.0

    The Metrosep A Supp 17 columns are anion separation columns for use at room temperature with a very good price-performance ratio. The Metrosep A Supp 17 - 100/4.0 enables rapid separation of the standard anions. Thanks to its great flexibility with respect to flow rates (up to 1.8 mL/min), very short analysis times can be achieved, depending on the separation problem.

  • Metrosep A Supp 17 - 150/4.0
    6.01032.420
    Metrosep A Supp 17 - 150/4.0

    The Metrosep A Supp 17 - 150/4.0 separation column is the column of choice for anion determinations that require good separating efficiency and short separation times at room temperature. The maximum flow rate of 1.4 mL/min offers in this connection the possibility of optimizing the determination. The Metrosep A-Supp-17 columns convince with their good price-performance ratio.

  • Metrosep A Supp 17 - 250/4.0
    6.01032.430
    Metrosep A Supp 17 - 250/4.0

    The Metrosep A Supp 17 - 250/4.0 combines high separating efficiency with a good price-performance ratio without requiring the use of a column oven. The polystyrene/divinylbenzene basic material used guarantees a long service life for the column. Complex separation tasks can be solved on this column.

  • Metrosep A Supp 17 Guard/4.0
    6.01032.500
    Metrosep A Supp 17 Guard/4.0

    The Metrosep A Supp 17 Guard/4.0 reliably protects the Metrosep A Supp 17 analytical separation columns against contamination. Thanks to the "On Column Guard System", the guard column is very easy to handle. The guard column screws easily and directly onto the analytical column. No tools are required.

  • Metrosep A Supp 17 S-Guard/4.0
    6.01032.510
    Metrosep A Supp 17 S-Guard/4.0

    The Metrosep A Supp 17 S-Guard/4.0 reliably protects the Metrosep A Supp 17 analytical separation columns against contamination. The guard column is connected to the separation column simply using capillary connections. No tools are required.

  • Upgrade Kit: IC Eco
    6.05800.060
    Upgrade Kit: IC Eco

    Upgrade Kit for retrofitting the Eco IC with a pulsation absorber.