Metrosep C Supp 1 - 250/4.0

Metrosep C Supp 1 - 250/4.0
Beställningsnummer: 6.1052.430

The Metrosep C Supp 1 - 250/4.0 separation column is used for difficult separations of standard cations, some transition cations and amines in the low concentration range. Conductivity detection after sequential suppression allows for low detection limits thanks to low baseline noise.

  • Tekniska specifikationer
  • Dokument
  • Alternativ
  • Kromatogram
Carrier material Polyvinyl alcohol with carboxyl groups
Column capacity 30 µmol (K+)
Column dimensions 250 x 4.0 mm
Eluents Nitric acid eluent (standard eluent)

Nitric acid (c = 1 mol/L): 5.0 mmol/L; 10 mL/2 L
Rubidium (from rubidium nitrate): 50 µg/L Rb+; 172.5 µg/2 L (RbNO3)
Housing material PEEK
Max. pressure 15 MPa
Maximum flow 1.5 mL/min
Organic modifier 0 - 50% acetonitrile, 0 - 30% acetone, no methanol
Particle size 5 µm
pH range 1...12
Standard flow 1.0 mL/min
Standard temperature 40 °C
Temperatur range 20...40 °C
  • Brochure: Cation suppression in ion chromatography – Cation determination in the trace range (english)
    • Prospectus : Suppression cationique en chromatographie ionique – déterminations des cations dans le domaine des traces (français)
    • Prospekt: Kationensuppression in der Ionenchromatographie – Kationenbestimmung im Spurenbereich (deutsch)
  • Catalog: The column program 2018 (english)
    • Katalog: Das Säulenprogramm 2018 (deutsch)
  • Columns manual for Metrosep C Supp 1 (english)
    • Säulenhandbuch Metrosep C Supp 1 (deutsch)
  • Leaflet for Metrosep C Supp 1-XXX/4.0, German, English, French, Spanish

Ladda ner hela leveransomfattningen och extra tillbehör som PDF

  • Metrosep C Supp 1 Guard/4.0
    6.1052.500
    Metrosep C Supp 1 Guard/4.0

    The Metrosep C Supp 1 Guard/4.0 contains the C-Supp-1 column material and is used to protect Metrosep C-Supp-1 cation columns. Particles and contaminations are reliably retained, allowing the service life of the analytical separation column to be prolonged considerably. The Metrosep C Supp 1 Guard/4.0 also functions according to the "On Column Guard System" and is screwed directly onto the separation column with nearly no dead volume.

  • Metrosep C Supp 1 S-Guard/4.0
    6.1052.510
    Metrosep C Supp 1 S-Guard/4.0

    The Metrosep C Supp 1 S-Guard/4.0 contains the C-Supp-1 column material and is used to protect Metrosep C-Supp-1 cation columns. Particles and contaminations are reliably retained, allowing the service life of the analytical separation column to be prolonged considerably.