Applications
- 410000005-BPortable Raman Instrumentation for SERS Applications
For SERS developers and end users of SERS for specific applications to investigate low concetation levels of compounds, the centerpiece of their technological platform must be a Raman setup that provides reliable lab grade performance and is affordable and portable, allowing them to tackle real world problems. The portable i-Raman Plus system coupled with a BAC151 video microscope sampling accessory provides an ideal setup. With the performance and flexibility of use with different laser spot size and power for SERS research.
- 410000029See-through ID with Raman technology
Metrohm’s ST Raman technology enables fast, contactless identification of substances through opaque packaging, expanding safe, field-ready use of Raman spectroscopy.
- 410000030-ASpectroscopie Raman à transmission portable pour le test atline de l'uniformité de la composition de comprimés pharmaceutiques
Les méthodes analytiques pour effectuer le test CU doivent dans l'idéal être rapides, non invasives et ne pas exiger de grande préparation de l'échantillon. Récemment, la spectroscopie par transmission en proche infrarouge (NIR) et la spectroscopie à transmission Raman ont toutes deux été explorées comme méthodes alternatives pour le test CU atline (près de la production) sans préparation de l'échantillon. Bien que rapide et non destructive, la spectroscopie à transmission NIR souffre d'une faible sélectivité chimique et de sa sensibilité aux modifications de l'environnement de test. La spectroscopie Raman à transmission associée à la modélisation chimiométrique émerge rapidement comme technique appréciée pour le test CU en raison de sa haute spécificité chimique. C'est particulièrement utile lorsqu'il s'agit de formulations pharmaceutiques complexes.
- 410000031-ARapid Field Testing of Ecstasy Pills Using a 1064-nm Handheld Raman Device
B&W Tek’s TacticID®-1064 is a field-ready handheld Raman system utilizing 1064-nm wavelength laser excitation. Designed for forensic analysis by safety personnel, first responders, and law enforcement personnel, the TacticID-1064 significantly reduces fluorescence, allowing users to identify tough street samples such as ecstasy tablets in a variety of colors and mixture forms.
- 410000032-AAvantages et inconvénients de l'emploi de la corrélation par rapport aux algorithmes à variables multiples pour l'identification de matériaux par spectroscopie portative
Les deux principales représentations mathématiques utilisées comme outils de décision pour les données spectroscopiques en spectroscopie Raman portative, à savoir l'indice de qualité de corrélation (en anglais Hit Quality Index = HQI) et le degré de signification (p-value) sont présentées.
- 410000040-ADirectives d'échantillonnage pour les mesures Raman portables – Ce que vous devez savoir
La spectroscopie Raman portable est utilisée pour tester les matières premières de différents types et formes d'échantillons. L'utilisation d'accessoires d'échantillonnage optimisé améliore l'utilité de la spectroscopie Raman portable sans compromis sur la qualité des données ni tests compliqués.
- 410000061-AIdentification of Starting Materials in Pharmaceutical industry using STRam®-1064
100% starting materials identification testing is one of the FDA’s directives as per 211.84 for FDA regulated industries such as Pharmaceutical, Vaccines, Cosmetics, Tobacco, Animal veterinary products, Food, etc. STRam®-1064 is a Raman analyzer uniquely suited for this purpose. It measures samples through thick packaging materials such as plastics, multilayer kraft paper sacks, and HDPE containers. A long wavelength laser is used to suppress fluorescence. The ID algorithm isolates the sample signature by subtracting that of the packaging material and compares that with library spectra to achieve identification.
- 8.000.6045Amines aliphatiques à l’état de trace dans les substances pharmaceutiques cationiques
Le défi analytique traité dans le présent document consiste à détecter des concentrations inférieures au ppb dans les amines de faible poids moléculaire en présence de substances cationiques fortement retenues par chromatographie ionique (CI) précédée d’une élimination de matrice par colonne couplée (CCME). Contrairement à l’injection directe CI, où l’élution tardive de substances retenues fortement nécessite des éluants avec addition d’acétonitrile, la technique CCME utilise deux colonnes de préconcentration montées en série. Au cours d’une phase d’élimination de matrice « inverse », la substance cationique et les amines cibles sont piégées sur une colonne de préconcentration à grande capacité et une à très grande capacité. Durant la détermination des amines, une solution rince la substance en déchet. Cela réduit considérablement le temps d’analyse et améliore la sensibilité ainsi que la sélectivité. Outre la détermination de monométhylamines dans le chlorhydrate de nébivolol traitée ici, la technique CCME est un outil plein de promesses pour la détection d’autres amines de faible poids moléculaire dans une large gamme de substances pharmaceutiques.
- 8.000.6078Détermination de la teneur en eau par la technique Karl Fischer automatisée dans les substances pharmaceutiques
Le poster décrit la détermination de la teneur en eau dans les substances pharmaceutiques au moyen de la technique au four Karl Fischer.
- 8.000.6102Chromatographie ionique – la solution polyvalente pour l'analyse pharmaceutique
L'analyse pharmaceutique garantit la sécurité des médicaments en fournissant des informations sur l'identité, le contenu, la qualité, la pureté et la stabilité des produits pharmaceutiques à l'aide de la chimie analytique. La chromatographie ionique (CI) offre un large éventail d'applications compatibles avec la pharmacopée en matière de contrôle qualité, contrôle et amélioration de la fabrication des médicaments.La CI, technique très précise et polyvalente, répond aux exigences de nombreuses applications pharmaceutiques. La CI est une méthode normalisée acceptée par l'USP pour déterminer les principes actifs pharmaceutiques (API), les excipients, les impuretés,les solutions pharmaceutiques ainsi que les matières premières pharmaceutiques, les produits pharmaceutiques finis (FPP), et même les fluides corporels.Cette affiche présente quelques exemples typiques.
- 8.000.6105Détermination sélective et sensible du zinc dans une grande variété de formules en vente libre selon le chapitre <591> de l'USP
Cette affiche présentée conjointement avec l'USP lors du congrès de l'AAPS expose la nouvelle méthode USP pour le zinc conformément au chapitre <591> au moyen de la chromatographie ionique, hautement sélective et sensible. La sélectivité est obtenue par séparation, puis améliorée par réaction de dérivatisation post-colonne. La sensibilité et la limite de quantification linéaire étendue font de cette nouvelle méthode USP la méthode idéale pour l'AQ/CQ. La réalisation automatisée de la dérivatisation post-colonne facilite la validation des performances générales de la méthode.
- 8.000.6107Initiative de modernisation USP : impuretés ioniques dans les substances médicamenteuses par chromatographie ionique
Cette affiche présentée conjointement avec l'USP lors du congrès de l'AAPS montre que nous avons validé avec succès une méthode de CI permettant de déterminer les chlorures et sulfates dans les substances médicamenteuses, le bicarbonate de potassium et le carbonate de potassium. La méthode de CI proposée surmonte les limites des méthodes de turbidimétrie ou de comparaison visuelle.
- 8.000.6109Initiative de modernisation USP : dosage d'iode par chromatographie ionique
L'iodure de potassium (KI) est utilisé dans le traitement de l'hyperthyroïdie et pour protéger la glande thyroïde des effets des radiations de l'iode radioactif inhalé ou avalé. Actuellement, dans la monographie d'iodure de potassium USP, l'iodure est identifié à l'aide d'un procédé chimique par voie humide et d'un dosage par titrage manuel, qui ont montré une fidélité et une exactitude moindres. Dans le cadre de l’initiative mondiale de modernisation de la monographie de l’USP, une méthode alternative sélective et sensible a été développée et validée – la chromatographie ionique (CI). La méthode CI proposée peut également servir au test d'identification comme alternative à la chimie par voie humide.
- 8.000.6110Le fluorure dans les médicaments en vente libre par chromatographie ionique
Le fluorure est couramment utilisé dans les produits dentaires pour la prévention de la carie dentaire. Lorsque le fluorure est présent à des concentrations élevées, ces produits sont réglementés par le 21 CFR 355. Trois composés fluorés utilisés dans les produits dentaires anticaries en vente libre sont le fluorure de sodium, le fluorure stanneux et le monofluorophosphate de sodium (MFP). Le dosage du fluorure dans ces ingrédients actifs et les formulations finies est déterminé par titrage manuel ou à l'aide d'électrodes ioniques spécifiques. Dans le cadre de l’initiative mondiale de modernisation de la monographie de l’USP, une méthode alternative sélective et sensible a été développée et validée – la chromatographie ionique (CI). La méthode CI proposée peut également servir au test d'identification comme alternative à la méthode de la chimie par voie humide.
- AB-098Détermination de l'acide ascorbique (vitamine C) et de ses composés
En plus des quantités naturellement présentes dans les fruits et légumes, l'acide ascorbique (vitamine C) est utilisé comme antioxydant dans les aliments et les boissons. L'acide ascorbique est par ailleurs présente dans de nombreux médicaments.L'acide ascorbique ainsi que ses sels et esters peuvent être déterminés par titrage ou polarographie, où l'acide ascorbique est oxydé en acide déhydroascorbique.Au cours de la détermination titrimétrique, il est possible d'employer une indication du point équivalent bi-voltamétrique ou photométrique. Il faut cependant remarquer que seule l'indication bi-voltamétrique est indépendante de la coloration individuelle de l'échantillon. La polarographie est la méthode la plus sélective des méthodes décrites, car les autres substances réductibles ou oxydantes ne sont pas détectées.
- AB-410Analyses pharmaceutiques au moyen de la spectroscopie proche infrarouge
Le présent Application Bulletin inclue des applications NIR et des études de faisabilité sur des instruments NIRSystems dans l'industrie pharmaceutique. Des analyses qualitatives et quantitatives d'échantillons les plus divers sont présentées dans ce bulletin. Chaque application décrit l'appareil qui fut utilisé à l'origine pour l'analyse ainsi que le système recommandé pour l'analyse et les résultats obtenus.
- AN-C-181Le potassium dans le bitartrate de potassium selon l'USP
Dans le cadre de la modernisation des monographies de l'USP, le potassium est déterminé dans du bitartrate de potassium par chromatographie cationique avec détection directe de la conductivité. La monographie USP41 consacrée au bitartrate de potassium ne mentionne pas encore de dosage du potassium. La séparation est réalisée sur une colonne Metrosep C 6 - 150/4,0 (L76). Le dosage du potassium est effectué selon les définitions USP à l'aide de deux produits disponibles dans le commerce. Les critères d'acceptation sont tous remplis sans exception.
- AN-C-182Le potassium dans le tartrate de sodium et de potassium selon l'USP
Dans le cadre de la modernisation des monographies de l'USP, le potassium est déterminé dans du tartrate de sodium et de potassium par chromatographie cationique avec détection directe de la conductivité. La monographie USP41 consacrée au tartrate de sodium et de potassium ne mentionne pas encore de dosage du potassium. La séparation est réalisée sur une colonne Metrosep C 6 - 150/4,0 (L76). Le dosage du potassium est effectué selon les définitions USP à l'aide de deux produits disponibles dans le commerce. Les critères d'acceptation sont tous remplis sans exception.
- AN-C-183Le potassium dans des comprimés effervescents de bicarbonate de potassium pour suspension orale selon l'USP
Dans le cadre de la modernisation des monographies de l'USP, le potassium est déterminé par chromatographie cationique avec détection directe de la conductivité dans des comprimés effervescents de bicarbonate de potassium pour suspension orale. La séparation est réalisée sur une colonne Metrosep C 6 - 150/4,0 (L76). Les critères d'acceptation sont tous remplis sans exception. La monographie USP41 consacrée aux comprimés effervescents de bicarbonate de potassium pour suspension orale réalise le dosage du potassium par spectroscopie d'absorption atomique.
- AN-C-184Le potassium et le sodium dans des comprimés effervescents de bicarbonate et d'acide citrique pour suspension orale selon l'USP
Dans le cadre de la modernisation des monographies de l'USP, le potassium et le sodium sont déterminés par chromatographie cationique avec détection directe de la conductivité dans des comprimés effervescents de bicarbonate et d'acide citrique pour suspension orale. La séparation est réalisée sur une colonne Metrosep C 6 - 150/4,0 (L76). Les critères d'acceptation sont tous remplis sans exception. La monographie USP41 consacrée aux comprimés effervescents de bicarbonate et d'acide citrique pour suspension orale réalise le dosage du potassium par photométrie de flamme.
- AN-C-185Le potassium dans des comprimés effervescents de bicarbonate de potassium et de chlorure de potassium pour suspension orale selon l'USP
Dans le cadre de la modernisation des monographies de l'USP, le potassium est déterminé par chromatographie cationique avec détection directe de la conductivité dans des comprimés effervescents de bicarbonate de potassium et de chlorure de potassium pour suspension orale. La séparation est réalisée sur une colonne Metrosep C 6 - 150/4,0 (L76). Les critères d'acceptation sont tous remplis sans exception. La monographie USP41 consacrée aux comprimés effervescents de bicarbonate de potassium et de chlorure de potassium pour suspension orale réalise le dosage du potassium par spectroscopie d'absorption atomique.
- AN-C-186Le sodium dans le tartrate de sodium et de potassium selon l'USP
Dans le cadre de la modernisation des monographies de l'USP, le sodium est déterminé dans du tartrate de sodium et de potassium par chromatographie cationique avec détection directe de la conductivité. La monographie USP41 consacrée au tartrate de sodium et de potassium ne mentionne pas encore de dosage du sodium. La séparation est réalisée sur une colonne Metrosep C 6 - 150/4,0 (L76). Le dosage du potassium est effectué selon les définitions USP à l'aide de deux produits disponibles dans le commerce. Les critères d'acceptation sont tous remplis sans exception. Voir l'AN-C-182 pour la détermination respective du potassium. L'application de cette méthode permet de déterminer le sodium et le potassium simultanément selon l'USP.
- AN-CIC-026Fluor organique lié dans l'ézétimibe par couplage CIC
L'ézétimibe est un médicament réduisant le cholestérol. Il réduit la résorption du cholestérol dans l'intestin grêle. La molécule contient deux groupes fluorophényle. La quantité de fluor dans le médicament est déterminée par application du couplage CIC (combustion chromatographie ionique). Pour éviter une introduction excessive de fluorure dans le système, l'ézétimibe est dissous dans de l'éthanol avant la combustion.
- AN-CS-015Limite de la choline dans le suxaméthonium sur une Metrosep C Supp 1 - 150/4,0 respectant scrupuleusement l'USP
Le suxaméthonium (ou succinylcholine) est un agent paralysant au délai d'action court utilisé, par exemple, pour l'intubation trachéale. La choline est un constituant de base du médicament qu'il faut considérer comme une substance étrangère. L'USP applique la chromatographie cationique avec détection de la conductivité après suppression. La composition de l'éluant et le type de colonne ne sont pas exactement conformes à l'USP. Cependant, les résultats répondent aux exigences respectives. La teneur en choline de l'échantillon n'est pas conforme aux spécifications USP.
- AN-D-003Contrôle de la qualité des concentrés de dialyse
La chromatographie ionique (IC) fournit une solution automatisée, rapide et sensible pour quantifier avec précision les composants cationiques et anioniques, y compris l'acétate, simultanément. Cette approche globale fait de l’IC une alternative économique aux techniques traditionnelles de contrôle qualité des solutions pharmaceutiques comme les concentrés d’hémodialyse. La facilité d'utilisation, la précision et le débit élevé des circuits intégrés augmentent la productivité et répondent aux exigences des laboratoires de routine et de recherche modernes.
- AN-K-038Détermination de l'eau dans la N-acétyle-L-cystéine
Le titrage Karl Fischer peut être utilisé pour déterminer la teneur en eau de la N-acétyl-L-cystéine. Des mélanges de solvants spéciaux peuvent être utilisés pour éviter des réactions secondaires indésirables lors du titrage Karl Fischer. La teneur en eau de la N-acétyl-L-cystéine peut ainsi être déterminée rapidement et avec précision, comme le montre la présente note d'application.
- AN-K-044Détermination de l'eau dans le panthénol
La teneur en eau dans le panthénol est déterminée selon Karl Fischer.
- AN-NIR-078Analyse automatisée de l'humidité dans les peptides pharmaceutiques
La quantification de l'humidité résiduelle dans les peptides pharmaceutiques lyophilisés est une mesure importante pour le contrôle de la qualité dans l'industrie pharmaceutique. À des fins de développement, de telles mesures sont nécessaires et régulièrement effectuées au cours des études de stabilité et pour optimiser le processus de lyophilisation. Actuellement, le titrage Karl Fischer est largement utilisé pour la détermination de l'humidité dans les analyses de routine. Cependant, cette méthode prend du temps et détruit l'échantillon pendant l'analyse. Cette note d'application montre que la spectroscopie dans le proche infrarouge (NIRS) est une méthode rapide, sans réactif et non destructive pour déterminer le taux d'humidité dans les produits pharmaceutiques lyophilisés.
- AN-NIR-099Quality Control of fermentation broths
Cell fermentation processes are a reliable production method for small molecules and protein-based active pharmaceutical ingredients (APIs). The fermentation process requires monitoring of many different parameters to ensure optimal production. These quality parameters include pH, bacterial content, potency, glucose, and concentration of reducing sugars. Traditional laboratory analysis takes a significant amount of time and requires different analytical techniques to monitor these different quality parameters. Near-infrared spectroscopy (NIRS) offers a faster and more cost-efficient alternative to traditional methods for the determination of critical parameters in fermentation broths at any stage of the fermentation process.
- AN-NIR-101Quality control of dried cannabis
Typically, cannabis potency testing is performed by HPLC, but the drawback is that it requires chemicals and it is time-consuming. Near-infrared spectroscopy (NIRS) is a preferred method for quantification of THC, CBD and CBG in dried cannabis because it provides results in less than a minute and does not require any chemicals.
- AN-P-089Lactose intolerance and reliance on accurate food labels
Worldwide, milk and dairy products are vital sources for human nutrition. A major component and energy source in dairy products is lactose. To efficiently metabolize lactose, the enzyme lactase is indispensable. However, globally nearly 70% of the population is lactose intolerant and they have difficulties to digest lactose. Lactose malabsorption leads to numerous gastrointestinal and extra-intestinal symptoms and other complaints with varying extents. Therefore, consumers rely on accurate food labels and for manufacturers appropriate sensitive analytical techniques are a must to comply with these demands. Ion chromatography with pulsed amperometric detection (IC-PAD) enables the determination of very low lactose contents. Validation according to AOAC requirements shows the high sensitivity and reliability of this method as a routine analysis.
- AN-RS-032Raman and SERS identification of a combination prescribed opioid
Handheld Raman spectrometers are valued for their ability to provide onsite material identification in seconds. In the case of combination pharmaceuticals, a single tablet contains more than one active ingredient in different proportions. MIRA DS is uniquely capable of identifying multiple compounds in such tablets by using Raman to identify the major component and SERS (surface-enhanced Raman spectroscopy) for the minor component. This application describes quick, dual analysis of a prescription medication containing acetaminophen and hydrocodone. The application is easily extrapolated to the study of street drugs.
- AN-RS-034Orbital Raster Scan (ORS™)
- AN-RS-044Optimize raw material identification and verification (RMID) with MIRA P
This Application Note explains how to scale MIRA P usage across an entire manufacturing operation by transferring models between different MIRA P instruments.
- AN-RS-045Transition RMID Operations Between Handheld Raman Devices
This application shows how to seamlessly transition from Metrohm’s NanoRam 785 to the newer MIRA P system, ensuring continuity in raw material identification (RMID).
- AN-RS-055Low-frequency Raman spectroscopy
Low frequency Raman spectroscopy extends conventional Raman analysis by capturing vibrational modes down to 65 cm-1, enabling deeper insights into molecular structure, protein characterization, polymorph identification, and phase changes.
- AN-S-286Sulfate and sulfamate analysis in Topiramate as per USP 33 - NF 28 Suppl. 1
Topiramate is an antiepilepsy drug. According to USP Topiramate tablets have to be tested for impurities. The determination of sulfate and sulfamate is mentioned under 'Specific Tests'. The isocratic method applies a column eluent combination primarily used for non-suppressed IC. But as sulfamate shows a negative peak under theses conditions the use of suppression is advantageous.
- AN-S-361Nitrite dans l'eltrombopag à l'aide l'élimination de la matrice inline
L'eltrombopag est un composé pharmaceutique utilisé dans certaines formes de thrombocytopénies. Il s'agit d'un médicament orphelin. La molécule d'eltrombopag est un composé carboxyle aromatique protoné. Dans les conditions de la chromatographie ionique, (éluant alcalin), il peut être déprotoné et peut ainsi bloquer les sites d'échange d'ions sur la colonne. Ceci entraîne une baisse du temps de rétention avec le temps. Afin d'éviter cela, l'élimination de la matrice inline est utilisée, l'eltrombopag protoné est alors éliminé de la colonne de préconcentration avant injection. Le nitrite est ensuite analysé par détection de conductivité après suppression séquentielle.
- AN-S-369Le phosphite et le phosphate dans l'acide pamidronique par détection de la conductivité avec suppression
L'acide pamidronique est utilisé dans le traitement de l'ostéoporose en fortifiant les os. C'est un bisphosphonate contenant un groupe amine primaire. Le phosphite et le phosphate sont des composés apparentés qu'il s'agit de quantifier. L'USP impose l’utilisation de l'acide formique comme éluant avec détection d'indice de réfraction. Mais une procédure CI standard offre une alternative d'une meilleure sensibilité. Le phosphite et le phosphate sont analysés par détection de conductivité après suppression séquentielle.
- AN-S-373Le chlorure dans des comprimés effervescents de bicarbonate de potassium et de chlorure de potassium pour suspension orale
Dans le cadre de la modernisation des monographies de l'USP, le chlorure est déterminé par chromatographie cationique avec détection directe de la conductivité après suppression séquentielle dans des comprimés effervescents de bicarbonate de potassium et de chlorure de potassium pour suspension orale. La séparation est réalisée sur une colonne Metrosep A Supp 16 - 100/4,0 (L91). Les critères d'acceptation sont tous remplis sans exception. La monographie USP41 consacrée aux comprimés effervescents de bicarbonate de potassium et de chlorure de potassium pour suspension orale réalise le dosage du chlorure par titrage.
- AN-S-397Dosage par CI pour le chlorure de sodium dans les comprimés de chlorure de sodium pour solution
Comme alternative au titrage, la chromatographie ionique (CI) avec détection de la conductivité supprimée a été approuvée par l'USP comme méthode validée pour quantifier la teneur en chlorure des comprimés de NaCl destinés à être dissous ou utilisés par voie orale.
- AN-S-400Assay of nitrite in sodium nitrite
In severe cases of cyanide poisoning, sodium nitrite is used along with sodium thiosulfate for treatment. This Application Note describes the nitrite ion chromatography assay with the Metrosep A Supp 4 column and suppressed conductivity detection. This column equivalency study was in cooperation with the USP according to the USP General Chapter <621>.
- AN-S-401Nitrite in duloxetine hydrochloride API
Nitrosamine presence in medicines, even at trace level poses high safety risks to patients (carcinogenic). Nitrosamine formation can be avoided by controlling and monitoring the nitrite concentration in pharmaceutical products and substances. This Application Note describes the analysis of nitrite in duloxetine hydrochloride with ion chromatography (IC).
- AN-S-402Nitrite in hydroxypropyl methylcellulose
Nitrosamine formation can be avoided by controlling the nitrite concentration in pharmaceutical products and processes. To monitor nitrosamine formation, sensitive analytical methods such as ion chromatography for the determination of nitrite in pharmaceutical products and substances are essential.
- AN-T-036Hydrochlorure de benzydamine dans une solution désinfectante
Détermination de l'hydrochlorure de benzydamine {1-benzyl-3-[3- (diméthylamino)-propoxy]-1H-indazole hydrochlorure} dans une solution désinfectante par titrage potentiométrique avec du tétraphénylborate de sodium utilisant l'électrode pour tensioactifs NIO.
- AN-T-083Titrage photométrique du sulfate de chondroïtine selon Ph. Eur. et USP
Cette Application Note (note d’application) décrit la détermination photométrique des sulfates de chondroïtine avec du chlorure de cétylpyridinium 1 comme titrant et au moyen de l’Optrode (660 nm). Cette méthode est conforme aux exigences de Ph. Eur. et de l’USP.
- AN-T-157Titrage potentiométrique automatique du sulfanilamide
La pureté du sulfanilamide a été déterminée à l'aide du titrage potentiométrique automatique avec du nitrite de sodium utilisé comme titrant. Du bromure de potassium a été additionné à la solution, puisque les ions de bromure catalysent le titrage par diazotation.
- AN-T-222Teneur en dioxyde de soufre des médicaments traditionnels chinois
Les remèdes de la médecine traditionnelle chinoise (MTC) gagnent en popularité dans d'autres cultures. Dans certaines MTC, le dioxyde de soufre (SO2) est utilisé comme conservateur, antioxydant et désinfectant. Les produits sont traités par sulfuration au gaz SO2. Or, le dioxyde de soufre est un gaz très toxique. Les autorités sanitaires mondiales ont fixé des limites strictes pour la teneur en SO2 des produits. Il est donc crucial de déterminer la teneur en dioxyde de soufre pour respecter ces limites. Dans cette méthode bien adaptée, la teneur en SO2 de différents produits naturels de MTC est analysée de manière fiable et précise conformément à la norme ISO 22590 à l'aide de l'Eco Titrator équipé d'une Optrode et d'hydroxyde de sodium comme réactif de titrage.
- AN-U-070Paracétamol dans les comprimés avec préparation des échantillons entièrement automatisée par le 815 Robotic Soliprep pour LC
Le paracétamol est un analgésique et fébrifuge efficace. Sa détermination dans les comprimés par chromatographie en phase inverse et détection UV est simple et rapide avec la préparation des échantillons décrite dans cette Note. Le 815 Robotic SoliPrep pour LC se charge de tout de manière entièrement automatique : de la dissolution des comprimés à l'injection en boucle de 250 nL, en passant par l'homogénéisation et la filtration.
- AN-U-076Détermination de l'oxyde de zinc suivant le chapitre général <591>1) de l'USP
L'USP met à jour la monographie du chapitre général <591> « Détermination du zinc » afin d'y inclure la chromatographie ionique comme méthode d'analyse. L'oxyde de zinc est utilisé dans diverses crèmes de soins de la peau, dans des médicaments et produits pharmaceutiques. L'analyse par chromatographie ionique implique la séparation du zinc à l'aide, par exemple, de L91 (Metrosep A Supp 10) suivie d'une réaction post-colonne par le 4-(2-pyridylazo)résorcinol (PAR) comme réactif et la détection subséquente à une longueur d'onde de 530 nm.Mots-clés : USP<591>
- AN-V-043Zinc dans des produits pharmaceutiques à base de plantes contre le cancer de la prostate
Détermination de zinc dans des produits pharmaceutiques à base de plantes contre le cancer de la prostate.
- AN-V-054Palladium dans des produits pharmaceutiques
La concentration de Pd dans des produits pharmaceutiques est déterminée par polarographie après digestion humide.
- AN-V-219Sn(II) in radiopharmaceuticals
Sodium pertechnetate (99mTc) radiopharmaceuticals are widely used in medical imaging diagnostic procedures to help diagnose a large number of diseases affecting the bones and major organs. These radiopharmaceuticals are usually prepared from cold kits consisting of several ingredients, including a reducing agent. Sn(II) is a typical reducing agent which reduces the Tc(VII) that is added to the cold kit to a lower oxidation state which then forms the stable organic complex.For quality control, the tin content has to be determined in the kit vial. Sn(II) can be selectively determined using differential pulse polarography. Polarography is a straightforward, sensitive, selective, and interference-free method for the determination of mg/L levels of Sn(II) in radiopharmaceuticals.
- AN-V-240Determination of total iodine in thyroid tablets with polarography
Accurate iodine determination in thyroid tablets, ensuring treatment efficacy, is achieved using the 884 Professional VA and Multi-Mode Electrode pro per USP guidelines.
- BWT-4903Spectromètre portable NanoRam : idéalement adapté à l'inspection de matières premières et de produits chimiques utilisés dans l'industrie pharmaceutique
Le spectromètre portable NanoRam avec un spectromètre à refroidissement thermoélectrique et la technologie CleanLaze brevetée intégrés dans un petit boîtier à écran tactile fournit des possibilités de test de haute qualité des matières premières utilisées par l'industrie pharmaceutique.
- BWT-4905Le spectromètre portable NanoRam est totalement conforme à la réglementation relative à l'inspection des matières premières et des produits chimiques utilisés dans l'industrie pharmaceutique.
Le NanoRam est un spectromètre Raman portable de pointe pour l'identification rapide de produits chimiques utilisés dans les processus de fabrication de l'industrie pharmaceutique. Il a été spécifiquement conçu pour ces applications et est totalement conforme à la plupart des réglementations mondiales appliquées par les agences de contrôle, de sécurité et d'affaire s'adressant à l'industrie pharmaceutique.
- BWT-4911Utilisation de la spectroscopie Raman portable pour réduire les risques des matériaux utilisés en fabrication
La spectroscopie Raman est un outil performant capable de fournir une analyse spécifique rapide pour l'identification de matières premières. Elle réduit le risque d'utilisation en fabrication de matières non conformes aux exigences ou erronées. L'utilité de la spectroscopie Raman portable augmente la productivité avec la possibilité de réaliser un test complet sans créer de goulot d'étranglement en production. L'intégration des données Raman dans le système de gestion des données de la société fournit un moyen sûr de traiter les données et les résultats avec un risque réduit d'erreur de transcription et de perte de données.
- BWT-4912Analyse quantitative à l'aide de spectromètres Raman de nouvelle génération et de la chimiométrie – Miniaturisation et célérité
De petits spectromètres Raman quasi à haute performance sont d'ores et déjà disponibles. Nous examinons trois exemples pratiques d'applications d'analyse quantitative et semi-quantitative. Cette vitrine applicative montre la polyvalence de la spectroscopie Raman et l'impact potentiel qu'elle peut avoir dans différente secteurs comme la sécurité, l'industrie pharmaceutique, la plasturgie et les polymères.
- WP-017La spectroscopie proche infrarouge dans les pharmacopées
L'industrie pharmaceutique est soumise à une réglementation plus exhaustive que n'importe quelle autre branche. Elle a donc besoin de méthodes d'analyse répondant aux exigences des réglementations tout en se montrant pratiques. Cela est particulièrement vrai en présence de grandes quantités d'échantillons, tel que dans le cadre du contrôle d'entrée des marchandises. Dans un tel cas, il est nécessaire de disposer de méthodes d'analyse simples et rapides, simplifiant les analyses de routine et permettant de les organiser de façon plus efficace. Ce livre blanc présente quelques-uns des règlements les plus importants dans le domaine de l'analyse pharmaceutique et démontre comment la spectroscopie Vis-NIR permet de résoudre les problématiques analytiques de l'industrie pharmaceutique conformément aux réglementations.
- WP-019La chromatographie ionique – une technique universelle aux nombreuses applications dans l'industrie pharmaceutique
La chromatographie ionique est une technique souple offrant un grand choix d'applications à l'industrie pharmaceutique. – Quelques tendances de développement et les derniers progrès en la matière sont présentés ici.
- WP-045Là où la CLHP échoue : la chromatographie ionique pour les analyses agro-alimentaires et pharmaceutiques ainsi que celles de l'eau
La chromatographie en phase liquide à haute performance (CLHP) et la chromatographie ionique (CI) sont couramment utilisées dans les secteurs pharmaceutique, agro-alimentaire et environnemental afin d'analyser des échantillons de composants spécifiques et de vérifier la conformité avec les normes et les réglementations. Les utilisateurs de la CLHP peuvent néanmoins toucher aux limites de cette technique, par exemple lors de l'analyse d'anions standard ou de certaines impuretés pharmaceutiques. Ce livre blanc explique comment surmonter de tels défis à l'aide de la CI.
- WP-054Booster l'efficacité en laboratoire de contrôle qualité ou comment la NIRS permet de réduire jusqu'à 90 % des coûts
La sous-estimation des procédures de contrôle qualité (CQ) est l'un des principaux facteurs entraînant une défaillance interne et externe des produits, dont il est rapporté qu'elle aurait provoqué entre 10 et 30 % de pertes de chiffre d'affaires. En conséquence, bon nombre de normes ont été mises en place pour assister les fabricants dans leur procédure de contrôle qualité. Cependant, le temps de résultat et les coûts associés aux produits chimiques peuvent être parfois excessifs, ce qui conduit de nombreuses entreprises à introduire la spectroscopie proche infrarouge (NIRS) dans leur procédure de contrôle qualité. Cet article montre les possibilités offertes par la spectroscopie proche infrarouge et indique des économies potentielles pouvant atteindre 90 % des coûts.
- WP-062Surmonter les difficultés rencontrées lors de la mesure des ions : conseils pour l'addition standard et la mesure directe
La mesure des ions peut s'effectuer de différentes manières, par exemple par la chromatographie ionique (CI), la spectrométrie d'émission optique à plasma à couplage inductif (ICP-OES) ou la spectroscopie d'absorption atomique (SAA). Chacune de ces méthodes est bien établie et communément utilisée dans les laboratoires d'analyse. Toutefois, les coûts initiaux sont relativement élevés. La mesure des ions à l'aide d'une électrode ionique spécifique (EIS) se révèle être, au contraire, une alternative prometteuse à ces techniques coûteuses. Ce livre blanc explique les difficultés que l'on peut rencontrer lors d'une application d'addition standard ou de la mesure directe, et la manière de les surmonter afin que les analystes acquièrent une plus grande confiance dans ce type d'analyse.
- WP-096Validation des méthodes de chromatographie ionique (IC) selon USP <1225>
Ce livre blanc traite de l'USP <1225> et de la manière dont la chromatographie ionique détermine les ingrédients actifs dans les produits pharmaceutiques (dosages) et identifie les impuretés et les composants de dégradation.