You have been redirected to your local version of the requested page
Solitrode with Pt1000 (IP67, fixed cable 1.2 m)

Solitrode with Pt1000 (IP67, fixed cable 1.2 m)

6.0228.030

Solitrode with Pt1000 (IP67, fixed cable 1.2 m)

en

6.0228.030

Feature overview

Combined pH electrode with integrated temperature sensor (Pt1000) and fixed cable conforming to IP67 (1.2 m).
This electrode is suitable for an introduction to GLP-compliant pH measurements in solutions that do not contain precipitates, proteins, or sulfides. This electrode is mechanically resistant thanks to the robust/unbreakable plastic shaft made of polypropylene and impact protection for the glass membrane.
Additionally, this electrode offers a waterproof plug in accordance with IP67 for mobile use with Metrohm pH meters.
Reference electrolyte: c(KCl) = 3 mol/L, storage in storage solution.

Tech specs

SGJ sleeveFlexible SGJ sleeve
Membrane glass typeT
Resistance (kOhm)5
Shaft material (completion)Glass/FKM
Shaft materialPP
Measuring unitpH
Temperature range, long-term (°C)0 ... 80
Temperature range, short-term (°C)0 ... 80
pH range0 ... 14
Max. installation length (mm)113
Shaft diameter top (mm)12
Shaft diameter bottom (mm)12
Min. immersion depth (mm)15
Electrode plug-in headFixed cable with plug I (IP67) + 1 x 2 mm
Indicator electrode shapeHemisphere
Membrane resistance200 ... 400
Electrode zero point (mV)±15
Electrode slope>0.97
Temperature sensorPt1000 (2 mm)
DiaphragmCeramic diaphragm
Reference electrolyte typec(KCl) = 3 mol/L
Electrolyte flow rate (μl/h) at 10 cm water column5 ... 25
Diaphragm resistance (kOhm)0.5 ... 5
This field is required.
    • Sleeve with SGJ 14/12 mm
    • 6.1236.050
    • Sleeve with SGJ 14/12 mm, polyethylene.
    • Sleeve with SGJ 14/12 mm, polyethylene.
    • Stk
    • 100
    • Storage vessel 
    • 6.2008.040
    • Together with 6.2008.050 storage vessel holder. it provides a support for the electrode on 807 Dosing Units.
    • <p>Together with 6.2008.050 storage vessel holder. it provides a support for the electrode on 807 Dosing Units.</p>
    • Stk
    • 100
    • Grease (1 oz.)
    • 6.2803.000
    • Special quality (without silicone). For grease-free ground joint connections see 6.2713.XXX
    • Special quality (without silicone). For grease-free ground joint connections see 6.2713.XXX
    • g
    • 1
    • Sleeve with SGJ 14/12 mm
    • 6.1236.050
    • Sleeve with SGJ 14/12 mm, polyethylene.
    • Sleeve with SGJ 14/12 mm, polyethylene.
    • Stk
    • 100
    • Storage vessel 
    • 6.2008.040
    • Together with 6.2008.050 storage vessel holder. it provides a support for the electrode on 807 Dosing Units.
    • <p>Together with 6.2008.050 storage vessel holder. it provides a support for the electrode on 807 Dosing Units.</p>
    • Stk
    • 100
    • Grease (1 oz.)
    • 6.2803.000
    • Special quality (without silicone). For grease-free ground joint connections see 6.2713.XXX
    • Special quality (without silicone). For grease-free ground joint connections see 6.2713.XXX
    • g
    • 1
    • Electrolyte 3 mol/L KCl (250 mL)
    • 6.2308.020
    • Electrolyte solution c(KCl) = 3 mol/L, (for Ag/AgCl reference systems)
    • Electrolyte solution c(KCl) &#61; 3 mol/L, (for Ag/AgCl reference systems)
    • PCS
    • 1
    • Storage solution
    • 6.2323.000
    • Storage solution for all combined pH glass electrodes with reference electrolyte c(KCl) = 3 mol/L
    • Storage solution for all combined pH glass electrodes with reference electrolyte c(KCl) &#61; 3 mol/L
    • PCS
    • 1
    • pHit kit
    • 6.2325.000
    • Maintenance kit for pH electrodes The kit contains:50 mL cleaning solution; 50 mL 3M KCl solution; 50 mL storage solution; 2 Storage vessels; Instructions for use;
    • <p>Maintenance kit for pH electrodes </p><p>The kit contains:</p><ul><li>50 mL cleaning solution</li><li>50 mL 3M KCl solution</li><li>50 mL storage solution</li><li>2 Storage vessels</li><li>Instructions for use</li></ul>
    • PCS
    • 1
    • Cleaning solution 3 x 50 mL
    • 6.2325.100
    • Reliable measuring results over long periods of time can be guaranteed only if the pH glass membrane and the diaphragm receive preventive and regular care. Cleaning by etching with toxic chemicals or applying mechanical treatment to the diaphragm is not only complicated and expensive, it also accelerates the ageing of the pH glass electrode.The cleaning solution was developed for easy and gentle cleaning of pH glass electrodes. Regular use can considerably prolong their service life.This cleaning solution is also part of the pHit kit.
    • <p>Reliable measuring results over long periods of time can be guaranteed only if the pH glass membrane and the diaphragm receive preventive and regular care. Cleaning by etching with toxic chemicals or applying mechanical treatment to the diaphragm is not only complicated and expensive, it also accelerates the ageing of the pH glass electrode.<br />The cleaning solution was developed for easy and gentle cleaning of pH glass electrodes. Regular use can considerably prolong their service life.<br /><br />This cleaning solution is also part of the pHit kit.</p>
    • PCS
    • 1