663 VA Stand for Metrohm Autolab potentiostats

663 VA Stand for Metrohm Autolab potentiostats
Part Number: 2.663.0020

The 663 VA Stand is a voltammetric measuring stand for potentiostats from Metrohm Autolab. The 663 VA Stand can be used to perform polarographic and voltammetric measurements on the following electrodes: Multi-Mode electrode pro (MME), rotating disk electrodes or scTRACE Gold.

Delivery with complete accessories and all electrodes for a complete measurement system: Multi-Mode electrode pro (MME), Ag/AgCl reference electrode and Pt auxiliary electrode. Without cable and power supply unit. An IME663 interface is required as connector to the potentiostats from Metrohm Autolab.

  • Especificações Técnicas
  • Documentos
  • Peças
  • Opções
Dimensions in mm (W/H/D) 290/295/420
Dimensions remark Height with covering folded open: 570 mm

Faça o download do escopo completo de entrega e acessórios opcionais

  • Ag/AgCl reference electrode
    6.0728.020
    Ag/AgCl reference electrode

    Reference system with electrolyte c(KCl) = 3 mol/L.

    1 piece(s)

  • Stirrer for VA Stand
    6.1204.200
    Stirrer for VA Stand
    Stirrer for VA Stand, complete, metal-free

    1 piece(s)

  • Mercury drop capillary (silanized) for MME
    6.1226.050
    Mercury drop capillary (silanized) for MME


    Silanized mercury drop capillary (10 pieces)


    1 piece(s)

  • Electrode Holder
    6.1241.020
    Electrode Holder

    Electrode holder for 6.1247.XXX VA auxiliary electrodes.

    1 piece(s)

  • Driving belt
    6.1244.020
    Driving belt
    For Rotating Disk Electrodes and stirrer in VA Stands (3 pieces).

    1 piece(s)

  • Electrolyte vessel
    6.1245.010
    Electrolyte vessel

    Electrolyte vessel for reference electrode with ceramic diaphragm.

    1 piece(s)

  • Multi-Mode Electrode pro
    6.1246.120
    Multi-Mode Electrode pro
    Mercury electrode for voltammetry. Can be operated as DME, SMDE or HMDE.

    1 piece(s)

  • Glassy Carbon Rod (GC)
    6.1247.000
    Glassy Carbon Rod (GC)

    With 6.1241.020 electrode holder for VA auxiliary electrode.

    1 piece(s)

  • Needles for MME
    6.1247.020
    Needles for MME

    Needles for Multi Mode Electrode (3 pieces).

    1 piece(s)

  • Titration vessel / 10-90 mL
    6.1415.210
    Titration vessel / 10-90 mL

    1 piece(s)

  • Tubing for nitrogen connection
    6.1801.080
    Tubing for nitrogen connection
    For supplying gas to voltammetry instruments

    1 piece(s)

  • Pb Ion standard 1 g/L 50 mL
    6.2301.100
    Pb Ion standard 1 g/L 50 mL
    Pb ion standard, c(Pb2+ ) = 1.000 g/L

    1 piece(s)

  • Electrolyte  3 mol/L KCl (250 mL)
    6.2308.020
    Electrolyte 3 mol/L KCl (250 mL)
    Electrolyte solution c(KCl) = 3 mol/L, (for Ag/AgCl reference systems)

    1 piece(s)

  • Mercury drop catcher
    6.2406.000
    Mercury drop catcher
    Silver wire (to capture mercury drops by amalgamation)

    1 piece(s)

  • Stand ring for titration vessels
    6.2703.000
    Stand ring for titration vessels

    1 piece(s)

  • Stopper for pipetting opening
    6.2709.030
    Stopper for pipetting opening
    For 663 VA Stand

    1 piece(s)

  • Stopper for stirrer opening on VA Stand
    6.2709.050
    Stopper for stirrer opening on VA Stand
    E.301.0004 O-rings included. Used for the stirrer opening of VA Stands.

    1 piece(s)

  • Tray for filling the MME
    6.2711.030
    Tray for filling the MME

    For 884 Professional VA, 797 VA Computrace, 757 VA Computrace and 647, 663, 694, 747 VA Stands

    1 piece(s)

  • Syringe 10 mL with Luer connection
    6.2816.020
    Syringe 10 mL with Luer connection
    For various applications in IC and VA

    1 piece(s)

  • Needle with Luer connector
    6.2816.030
    Needle with Luer connector

    Needle for filling in mercury into the Multi-Mode Electrode and for sample addition in Karl Fischer titration.


     


    1 piece(s)

Faça o download do escopo completo de entrega e acessórios opcionais

  • Separate Pt Rod Electrode
    6.0343.000
    Separate Pt Rod Electrode

    Auxiliary electrode for VA stands.

  • Ag/AgCl reference electrode
    6.0728.010
    Ag/AgCl reference electrode

    Reference system without electrolyte.


  • Silver Electrode Tip
    6.1204.130
    Silver Electrode Tip

    Metal electrode tip, silver (Ag). Electrode disk diameter 2 mm. M3 thread. Temperature range: 0 ... 40 °C.

  • Gold Electrode Tip
    6.1204.140
    Gold Electrode Tip

    Metal electrode tip, gold (Au). Electrode disk diameter 2 mm. M3 thread. Temperature range: 0 ... 40 °C.

  • Lateral Gold Electrode Tip
    6.1204.150
    Lateral Gold Electrode Tip

    Metal electrode tip, gold (Au), with lateral electrode surface. Electrode disk diameter 3 mm. M3 thread. Temperature range: 0 ... 40 °C.

  • 3 mm platinum electrode tip for CVS
    6.1204.170
    3 mm platinum electrode tip for CVS

    Metal electrode tip made of platinum (Pt), diameter of electrode disk 3 mm, polished surface, M3 thread connection. Temperature range: 0 - 40 °C.

  • Ultra Trace electrode tip
    6.1204.180
    Ultra Trace electrode tip


    Carbon electrode tip from Ultra Trace graphite. Electrode disk diameter 2 mm. M3 thread connection. Temperature range: 0 - 40 °C.


  • 1 mm platinum electrode tip for CVS
    6.1204.190
    1 mm platinum electrode tip for CVS

    Metal electrode tip made of platinum (Pt), diameter of electrode disk 1 mm ±0.02 mm, polished surface, shaft made of glass, M3 thread connection. Concentricity error: < 0.2 mm. Temperature range: 0 - 50 °C.

  • Driving axle for rotating disk electrode (RDE)
    6.1204.210
    Driving axle for rotating disk electrode (RDE)

    Driving axle for rotating disk electrode (RDE) with titanium axle for VA measuring stands, M3 thread.

  • Driving axle for rotating disk electrode (RDE) with mercury contact
    6.1204.220
    Driving axle for rotating disk electrode (RDE) with mercury contact

    Driving axle for rotating disk electrode (RDE) with titanium axle and mercury contact for VA measuring stands, M3 thread.

  • 
      
    Glassy carbon electrode tip, shaft made of glass.
                
         
    6.1204.600
    Glassy carbon electrode tip, shaft made of glass.  


    Carbon electrode tip made of Glassy-Carbon (GC). Diameter of electrode disk 2 mm ±0.1 mm, polished surface, shaft made of glass, M3 thread connection, concentricity deviation: <0.25 mm. Temperature range: 0 - 50°C. 


  • 2 mm platinum electrode tip for CVS
    6.1204.610
    2 mm platinum electrode tip for CVS

    Metal electrode tip made of platinum (Pt), diameter of electrode disk 2 mm ±0.05 mm, polished surface, shaft made of glass, M3 thread connection. Concentricity error: < 0.3 mm. Temperature range: 0 - 50 °C.

  • Titration vessel / 5-70 mL
    6.1415.150
    Titration vessel / 5-70 mL
  • Titration vessel / 20-90 mL
    6.1415.220
    Titration vessel / 20-90 mL
  • Titration vessel / 50-150 mL
    6.1415.250
    Titration vessel / 50-150 mL
  • Titration vessel with thermostat jacket / 5-70 mL
    6.1418.150
    Titration vessel with thermostat jacket / 5-70 mL
  • Titration vessel with thermostat jacket  / 20-90 mL
    6.1418.220
    Titration vessel with thermostat jacket / 20-90 mL
  • Titration vessel with thermostat jacket / 50-150 mL
    6.1418.250
    Titration vessel with thermostat jacket / 50-150 mL
  • PFA titration vessel / 10 to 90 mL
    6.1450.210
    PFA titration vessel / 10 to 90 mL
    For ultratrace analysis and for solutions containing fluoride.
  • Measuring vessel / 10-90 mL
    6.1456.210
    Measuring vessel / 10-90 mL
    Measuring vessel for automated VA systems. Dilution vessel for Advanced IC Sample Processor
  • Stopper for MME opening on VA Stand
    6.2709.040
    Stopper for MME opening on VA Stand
    For closing gas tubing of the Multi-Mode Electrode in VA Stands if not in use. E.301.0004 O-rings included.
  • Polishing set for solid-state electrodes
    6.2802.000
    Polishing set for solid-state electrodes
    Polishing set with 1 polishing cloth and about 2 g aluminum oxide powder (grain size 0.3 µm)
  • MVA-Hg, equipment for mercury determination
    6.5327.000
    MVA-Hg, equipment for mercury determination
    Complete set of accessories for the determination of mercury as per Application Bulletin 96. Contains rotating gold working electrode, reference electrode, glassy-carbon auxiliary electrode and other accessories.