896 Professional Detector – Conductivity & Amperometry


    896 Professional Detector – Conductivity & Amperometry
Artikkelnummer: 2.896.0030

Intelligent stand-alone detector equipped with the high performance IC Conductivity Detector and the IC Amperometric Detector, with the four measuring modes DC, PAD, flexIPAD and CV. For use with intelligent IC instruments or as independent detector for conductivity and amperometric detection.


  • Dokumenter
  • Delebetegnelse
  • Tilleggsutstyr
  • Declaration of conformity for 896 Professional Detector (english)
  • Manual 896 Professional Detector – Conductivity & Amperometry (english)
    • Handbuch 896 Prof. Detector-Amp-Cond, CN (中文)
    • Handbuch 896 Prof. Detector-Amp-Cond, CN (français)
    • Handbuch 896 Professional Detector – Conductivity & Amperometry (deutsch)
    • Handbuch 896 Prof. Detector-Amp-Cond, CN (español)

Last ned en komplett deleliste i PDF:

  • PEEK capillary 0.25 mm i.d. / 3 m
    6.1831.010
    PEEK capillary 0.25 mm i.d. / 3 m
    For all IC components.

    1 piece(s)

  • PEEK capillary 0.75 mm i.d. / 3 m
    6.1831.030
    PEEK capillary 0.75 mm i.d. / 3 m
    For all IC components.

    1 piece(s)

  • Cable USB A - USB B  1.8 m
    6.2151.020
    Cable USB A - USB B 1.8 m
    USB connecting cable

    1 piece(s)

  • Connecting cable to 61257XXX
    6.2165.000
    Connecting cable to 61257XXX
    Connecting cable for amperometric detector cell.

    1 piece(s)

  • Pressure screw 5x
    6.2744.010
    Pressure screw 5x
    With UNF 10/32 connection. For the connection of PEEK capillaries

    1 piece(s)

  • 
      
    Dummy cell to the IC Amperometric Detector.
    6.2813.040
    Dummy cell to the IC Amperometric Detector.
    Dummy cell for performance tests.

    1 piece(s)

Last ned en komplett deleliste i PDF:

  • Wall-Jet Cell
    6.1257.010
    Wall-Jet Cell

    Amperometric detector cell with Wall-Jet geometry.

  • 
    Thin-Layer cell
    6.1257.100
    Thin-Layer cell

    Amperometric detector cell with Thin-Layer geometry. For special applications and systems with higher backpressure (e.g. amperometry MS couplings).


  • 
    Au working electrode, 3 mm
    6.1257.210
    Au working electrode, 3 mm
    Working electrode made of gold for amperometric detection, 3 mm diameter.
  • GC working electrode
    6.1257.220
    GC working electrode

    Working electrode made of Glassy Carbon for amperometric detection, 3 mm diameter.


  • Pt working electrode
    6.1257.230
    Pt working electrode
    Platinum working electrode for amperometric detection, 3 mm diameter.
  • Ag working electrode
    6.1257.240
    Ag working electrode
    Silver working electrode for amperometric detection, 3 mm diameter.
  • 
    Au working electrode, 2 mm
    6.1257.260
    Au working electrode, 2 mm
    Working electrode made of gold for amperometric detection, 2 mm diameter.
  • Cu working electrode, 2 mm
    6.1257.270
    Cu working electrode, 2 mm

    Working electrode made of copper for amperometric detection, 2 mm diameter. Alternative working electrode for the gold electrode in carbohydrate analysis.

  • 
      
    Ag/AgCl reference electrode for 6.1257.xxx
    6.1257.720
    Ag/AgCl reference electrode for 6.1257.xxx


    Silver/silver chloride reference electrode for amperometric detection.


  • Pd reference electrode to 6.1257.xxx
    6.1257.740
    Pd reference electrode to 6.1257.xxx

    Palladium reference electrode for amperometric detection.

  • 50 µm spacer for the Wall-Jet cell.
    6.1257.810
    50 µm spacer for the Wall-Jet cell.

    50 µm spacer for the amperometric Wall-Jet cell, 3 pcs.

  • 
    50 µm spacer to Thin-Layer cell
    6.1257.820
    50 µm spacer to Thin-Layer cell

    50 µm spacer for the amperometric Thin-Layer cell, 3 pcs.


  • 25 µm spacer for the Wall-Jet cell
    6.1257.830
    25 µm spacer for the Wall-Jet cell

    25 µm spacer for the amperometric Wall-Jet cell, 3 pcs.

  • 
    25 µm spacer to Thin-Layer cell
    6.1257.840
    25 µm spacer to Thin-Layer cell

    25 µm spacer for the amperometric Thin-Layer cell, 3 pcs.


  • 
    Maintenance set for 6.1257.2XX working electrodes
    6.2802.200
    Maintenance set for 6.1257.2XX working electrodes

    Tool for removing protruding PEEK materials and for subsequent polishing of working electrodes including polishing disks.


  • 
    Polishing disks for 6.2802.200 maintenance set
    6.2802.210
    Polishing disks for 6.2802.200 maintenance set

    Replacement polishing disks for maintenance tool for 6.1257.2XX working electrodes.


  • IQ/OQ Kit for IC
    6.5333.000
    IQ/OQ Kit for IC
    The IQ/OQ Kit contains all parts and standard solutions required for IQ/OQ in ion chromatography.
  • IC equipment Wall-Jet cell: without electrodes
    6.5337.000
    IC equipment Wall-Jet cell: without electrodes

    Equipment comprised of Wall-Jet cell with additional accessories, without electrode.

  • IC equipment Wall-Jet cell: Carb (Au, Pd)
    6.5337.010
    IC equipment Wall-Jet cell: Carb (Au, Pd)

    Equipment comprised of Wall-Jet cell with additional accessories. For carbohydrate analysis with a gold working electrode and a Pd reference electrode.

  • IC equipment Wall-Jet cell: Cyanide (Ag, Pd)
    6.5337.020
    IC equipment Wall-Jet cell: Cyanide (Ag, Pd)

    Equipment comprised of Wall-Jet cell with additional accessories. For cyanide analysis with a silver working electrode and a Pd reference electrode.

  • IC equipment Wall-Jet cell: Anion (GC, Ag/AgCl).
    6.5337.030
    IC equipment Wall-Jet cell: Anion (GC, Ag/AgCl).

    Equipment comprised of Wall-Jet cell with additional accessories. For anion analysis with a Glassy Carbon and an Ag/AgCl reference electrode.

  • IC equipment Thin-Layer cell: without electrodes
    6.5337.200
    IC equipment Thin-Layer cell: without electrodes

    Equipment comprised of Thin-Layer cell with additional accessories, without electrodes.