Mira M-3 Advanced Package

Mira M-3 Advanced Package
Order number: 2.924.0020

The Metrohm Instant Raman Analyzer (MIRA) M-3 is a high performance, handheld Raman spectrometer used for rapid, nondestructive identification and verification of different material types, such as Pharmaceutical APIs and excipients. Despite the small size of the instrument, the Mira M-3 has a ruggedized design and features a high-efficiency spectrograph design equipped with our unique Orbital-Raster-Scan (ORS) technology. The Mira M-3 is fully compliant with FDA 21 CFR Part 11 regulations.

The Advanced Package includes an attachment lens for analyzing materials directly or through containers (laser Class 3b), as well as a vial holder attachment for analyzing materials contained in glass vials (laser Class 1).

  • Tech specs
  • Documents
  • Included parts
  • Opt. equipment
Barcode Scanner true
Battery life (h) ≥ 4h (with recommended batteries)
Height (mm) 45.0
Laser class according to EN 60825-1 Mira M-3 Basic Class 1
Laser output power (mW) ≤ 100 mW
Laser Wavelength (nm) 785.0
Length (mm) 128.0
Resolution (cm⁻¹) (FWHM) 14-16
Spectral Range (cm⁻¹) 400-2300
Touchscreen Display (inches) 3.7" Resistive or 9.4 cm
Weight (grams) 752.0
Width (mm) 88.0
  • Brochure: Mira M-3 portable Raman spectrometer – Material testing in seconds (english)
    • Brochure : Spectromètre Raman portable Mira M-3 - un contrôle des matériaux en l'espace de quelques secondes (français)
    • Prospekt: Mira M-3 tragbares Raman Spektrometer – Materialprüfung in Sekunden (deutsch)
    • Folleto: Espectrómetro Raman portátil Mira M-3 – Verificación de materiales en pocos segundos (español)
  • Brochure: Spectroscopy solutions for pharmaceutical analysis – Faster, safer, and much more economical (english)
  • Data sheet: Mira M-3 portable Raman spectrometer (english)
  • Declaration of Conformity for Mira M-3 (english)
  • Manual for Mira M-3 (english)
    • Mode d'emploi du Mira M-3 (français)
  • Release Notes Mira M-3 V0.1.0.7 (english)

Download the complete Scope of Delivery and Optional Accessories for as PDF:

  • 6.02707.000
    Carrying case for Mira M-3

    Protective case for the Mira M-3 and all accessories.

    1 piece(s)

  • 6.06071.010
    Mira Cal Pharma USB Stick

    Simple-to-use software that is primarily used for downloading and analyzing data, printing reports, creating spectral libraries and operating procedures, as well as managing 21 CFR Part 11 compliance.

    1 piece(s)

  • 6.06073.000
    Raman Spectral USP Library

    The USP library for the Mira M-3 contains more than 500 secondary USP standards for pharmaceutical API's and excipients.

    1 piece(s)

  • ASTM Calibration Standard
    6.07501.010
    ASTM Calibration Standard

    50:50 (v:v) Toluene/Acetonitrile ASTM standard for calibration of the wavenumber axis of Mira spectrometers.

    1 piece(s)

  • Vial Holder
    6.07502.000
    Vial Holder

    Vial holder attachment for Mira. Accommodates 15 x 26 mm glass vials.

    1 piece(s)

  • Attachment lens (LWD)
    6.07505.000
    Attachment lens (LWD)

    Long distance point-and-shoot Adapter (LWD) for the Mira Advanced Package with a focal length of 7.6 mm.

    1 piece(s)

  • Attachment lens (SWD)
    6.07505.010
    Attachment lens (SWD)

    Short distance point-and-shoot Adapter (SWD) for the Mira Advanced Package with a focal length of 1.00 mm.

    1 piece(s)

  • Lithium AA Batteries 1.5V/2,900 mA/h
    6.2133.020
    Lithium AA Batteries 1.5V/2,900 mA/h

    1.5V lithium AA batteries, 4 pieces.

    1 piece(s)

  • Cable USB MINI (OTG) - USB A, 1.8 m
    6.2151.110
    Cable USB MINI (OTG) - USB A, 1.8 m
    For connecting USB instruments.

    1 piece(s)

  • USB power supply unit 5V 1A R
    6.2166.000
    USB power supply unit 5V 1A R

    Power supply unit for the power supply of the 6.1115.100 Optrode if there is no USB connector available for this purpose on a Metrohm device (e.g. with older devices).


    1 piece(s)

  • Micro Fiber Cleaning Cloth
    6.7430.060
    Micro Fiber Cleaning Cloth

    Cleaning cloth for monitors and optics.

    1 piece(s)

  • Glass Vials for Mira
    6.7502.010
    Glass Vials for Mira

    Glass vials for use with Mira.
    15 mm x 26 mm.

    1 piece(s)

  • Protective laser glasses for Mira Advanced Packages
    6.7560.010
    Protective laser glasses for Mira Advanced Packages

    Protective laser glasses adjusted for the laser specifications of the Mira.

    1 piece(s)

Download the complete Scope of Delivery and Optional Accessories for as PDF:

  • 6.06073.601
    Complete collection of Raman spectra (> 8,690 spectra)

    Metrohm provides an extensive collection of Raman spectra for Mira spectrometers. The complete Raman spectral library, with more than 8,690 spectra, is comprised of 21 sublibraries and is thus eminently suited for the identification of unknown Raman spectra and for the characterization of a very wide variety of materials.

  • 6.06073.602
    Raman spectral library for the pharmaceutical industry

    Raman spectra of active substances and auxiliary materials that are relevant to the pharmaceutical industry and medical research (> 1,170)

  • 6.06073.603
    Raman spectral library for the solvents

    Raman spectra of solvents (> 460 spectra).

  • 6.06073.604
    Raman spectral library for the polymer industry

    Raman spectra of polymers, polymer additives, plastics, plasticizers, and packaging materials (> 920 spectra).

  • 6.06073.605
    Raman spectral library of aldehydes and ketones

    Raman spectra of aliphatic and aromatic aldehydes and ketones (> 1,070 spectra).

  • 6.06073.606
    Raman spectral library of alcoholic and phenolic compounds

    Raman spectra of alcoholic and phenolic compounds (> 890 spectra).

  • 6.06073.607
    Raman spectral library of esters, lactones, and anhydrides

    Raman spectra of esters, lactones, and anhydrides (> 2,930 spectra).

  • 6.06073.608
    Raman spectral library of (halogenated) hydrocarbons

    Raman spectra of hydrocarbons and halogenated hydrocarbons (> 560 spectra).

  • 6.06073.609
    Raman spectral library for the semiconductor industry

    Raman spectra of chemical substances that are used in the semiconductor industry (> 370 spectra).

  • 6.06073.610
    Raman spectral library of hazardous substances (EPA, USCG)

    Raman spectra of selected hazardous substances that are listed in the "EPA Cameo Database for Chemical Emergencies and Responders" and the "USCG CHRIS Hazardous Chemicals Database (> 1,360 spectra).

  • 6.06073.611
    Raman spectral library for hazardous substances (EPA, USCG, NIOSH)

    Raman spectra of selected hazardous substances that are listed in the "EPA Cameo Database for Chemical Emergencies and Responders", "USCG Chris Hazardous Chemicals Database" and "NIOSH Guide to Chemical Hazards Databases", as well as chemicals that are regulated by the "Toxic Substances Control Act" (> 3,030 spectra).

  • 6.06073.612
    Raman spectral library for forensic analysis

    Raman spectra of substances that are relevant to forensic analysis (> 740 spectra).

  • 6.06073.613
    Raman spectral library of agricultural chemicals

    Raman spectra of pesticides, insecticides, herbicides, fungicides, algicides, and similar agricultural chemicals (> 460 spectra).

  • 6.06073.614
    Raman spectral library for the dye industry

    Raman spectra of selected dyes, colorants, pigments, and indicators (> 300 spectra).

  • 6.06073.615
    Raman spectral library of sulfur and phosphorus compounds

    Raman spectra of sulfur and phosphorus compounds (> 970 spectra).

  • 6.06073.616
    Raman spectral library of substances with a high production volume

    Raman spectra of substances with a high production volume, as listed in the "HPV Challenge Program Chemical List" (> 690 spectra).

  • 6.06073.617
    Raman spectral library of minerals and inorganic materials

    Raman spectra of minerals and inorganic materials (> 1,410 spectra). This library is not included in the complete Raman spectral library (6.6071.601). The library is comprised of > 450 Raman spectra of minerals and > 960 Raman spectra of inorganic materials.

  • 6.06073.618
    Raman spectral library of minerals

    Raman spectra of minerals (> 450 spectra; extracted from the 6.6071.617 spectral library).

  • 6.06073.619
    Raman spectral library of inorganic materials

    Raman spectra of inorganic materials (>960 spectra; extracted from the 6.6071.617 spectral library).

  • 6.06073.620
    Raman spectral library of food additives

    Raman spectra of food additives, including FDA-controlled substances. Additionally, spectra of indirect food additives and substances that come into contact with foodstuffs, such as packaging materials and associated processing chemicals (> 1,070 spectra).

  • 6.06073.621
    Raman spectral library of biochemicals

    Raman spectra of biochemicals, including vitamins, resins, starches, glycerins, fatty acids, sugars, carbohydrates, proteins, and peptides (> 1,900 spectra).

  • 6.06073.622
    Raman spectral library of flavors and scents

    Raman spectra of flavors, scents, and other substances that are used for manufacturing cosmetics and fragrances (> 1,030 spectra).

  • Tablet Holder
    6.07504.000
    Tablet Holder

    Tablet holder attachment for the Mira M-3 that is used for analysis of formulated tablets of various sizes and shapes.

  • Mira Sampling Blackout Cloth
    6.07507.000
    Mira Sampling Blackout Cloth

    Optical Blackout cloth for sampling in sunlight conditions.