856 Conductivity Module with Touch Control, including conductivity measuring cell (stainless steel)

856 Conductivity Module with Touch Control, including conductivity measuring cell (stainless steel)
Order number: 2.856.0120

High-end conductometer, based on the 856 Conductivity Module, including 900 Touch Control, conductivity measuring cell (stainless steel) and calibration standards. The stainless steel measuring cell is particularly suitable for the measurement of low conductivities.

The Conductivity Module has two USB interfaces for connecting printers, barcode readers or sample changers and four MSB interfaces for stirrers or Dosinos. In combination with the 900 Touch Control, the 856 Conductivity Module is in compliance with GLP and FDA 21 CFR part 11 requirements.

  • Documents
  • Included parts
  • Opt. equipment

Download the complete Scope of Delivery and Optional Accessories for as PDF:

  • Conductivity measuring cell c = 0.1 cm-1 with Pt1000 (fixed cable)
    6.0916.040
    Conductivity measuring cell c = 0.1 cm-1 with Pt1000 (fixed cable)

    Conductivity measuring cell made of stainless steel with cell constant c = 0.1 cm-1, with integrated Pt1000 temperature sensor and fixed cable (1.2 m) for connecting to an 856 Conductivity Module.
    This sensor is suitable for measurements of low conductivities (0 uS/cm to 300 uS/cm) in e.g., deion. water or for measurements in accordance with USP <645>.

    1 piece(s)

  • Support stand without support rod
    6.2001.060
    Support stand without support rod
    To attach an 801, 804, 803 Stirrer to a Titrando, Titrino plus, Dosimat plus or 856 and 867.

    1 piece(s)

  • Clamping ring
    6.2013.010
    Clamping ring

    For support rods with a diameter of 10 mm.


    1 piece(s)

  • Support rod / 400 mm
    6.2016.070
    Support rod / 400 mm

    1 piece(s)

  • Electrode holder
    6.2021.020
    Electrode holder
    Electrode holder for 4 electrodes and 2 buret tips

    1 piece(s)

  • Conductivity standard 100 µS/cm, 5 x 30 mL
    6.2324.110
    Conductivity standard 100 µS/cm, 5 x 30 mL
    Conductivity standard for calibration of conductivity measuring cells with cell constant = 0.1/cm.

    1 piece(s)

  • 
    5 mm hex key for IC Sample Processors
    6.2621.070
    5 mm hex key for IC Sample Processors

    1 piece(s)

  • Hexagon key 2 mm
    6.2621.130
    Hexagon key 2 mm
    2 mm.

    1 piece(s)

  • USB Memory Stick for 900 Touch Control 
    6.6064.010
    USB Memory Stick for 900 Touch Control 

    1 piece(s)

Download the complete Scope of Delivery and Optional Accessories for as PDF:

  • USB thermal printer Neo's
    2.141.0100
    USB thermal printer Neo's

    Compact printer with USB interface for the Ti-Touch, the Titrino plus and Dosimat plus and the 91X Meter instruments.

    Paper width 60 mm (40 characters). Including 6.2151.120 USB cable.

  • 5-ring conductivity measuring cell c = 0.7 cm-1 with Pt1000 (fixed cable 2 m)
    6.0920.100
    5-ring conductivity measuring cell c = 0.7 cm-1 with Pt1000 (fixed cable 2 m)

    5-ring conductivity measuring cell with cell constant c = 0.7 cm-1, with integrated Pt1000 temperature sensor and fixed cable (2.0 m) for connecting to an 856 Conductivity Module in combination with a sample changer.
    This sensor is suitable for automated measurements of medium conductivities (5 uS/cm to 20 mS/cm), e.g., in:

    • drinking water
    • surface water
    • wastewater
  • 5-ring conductivity measuring cell c = 1.0 cm-1 with Pt1000 (fixed cable 2 m)
    6.0920.130
    5-ring conductivity measuring cell c = 1.0 cm-1 with Pt1000 (fixed cable 2 m)

    5-ring conductivity measuring cell with cell constant c = 1.0 cm-1, with integrated Pt1000 temperature sensor and fixed cable (2.0 m) for connecting to an 856 Conductivity Module in combination with a sample changer.
    This sensor is suitable for automated measurements of medium conductivities (5 uS/cm to 100 mS/cm), e.g., in:

    • drinking water
    • surface water
    • wastewater