- 8.000.6014Determination of anions and cations in aerosols by ion chromatography
The study of adverse effects of air pollution requires semi-continuous, rapid and accurate measurements of inorganic species in aerosols and their gas phase components in ambient air. The most promising instruments, often referred to as steam collecting devices, are the Particle-Into-Liquid-Sampler (PILS) coupled to wet-chemical analyzers such as a cation and/or anion chromatograph (IC) and the Monitoring instrument for AeRosols and GAses (MARGA) with two integrated ICs. Both instruments comprise gas denuders, a condensation particle growth sampler as well as pump and control devices. While PILS uses two consecutive fixed denuders and a downstream growth chamber, the MARGA system is composed of a Wet Rotating Denuder (WRD) and a Steam-Jet Aerosol Collector (SJAC). Although the aerosol samplers of PILS and MARGA use different assemblies, both apply the technique of growing aerosol particles into droplets in a supersaturated water vapor environment. Previously mixed with carrier water, the collected droplets are continuously fed into sample loops or preconcentration columns for on-line IC analysis. While PILS has been designed to sample aerosols only, MARGA additionally determines water-soluble gases. Compared to the classical denuders, which remove gases from the air sample upstream of the growth chamber, MARGA collects the gaseous species in a WRD for on-line analysis. In contrast to the gases, aerosols have low diffusion speeds and thus neither dissolve in the PILS denuders nor in the WRD. Proper selection of the ion chromatographic conditions of PILS-IC allows a precise determination, within 4 to 5 minutes, of seven major inorganic species (Na+, K+, Ca2+, Mg2+, Cl-, NO3- and SO4 2-) in fine aerosol particles. With longer analysis times (10-15 minutes) even airborne low-molecular-weight organic acids, such as acetate, formate and oxalate can be analyzed. MARGA additionally facilitates the simultaneous determination of HCl, HNO3, HNO2, SO2 and NH3.PILS and MARGA provide semi-continuous, long-term stand-alone measurements (1 week) and can measure particulate pollutants in the ng/m3 range.
- 8.000.6017Determination of sulfide in mining leachates
Metal precipitation and cyanide recovery in the SART process (sulfidization, acidification, recycling, thickening) depend to a great extent on the sulfide concentration. Among the flow injection analysis methods coupled to wet-chemical analyzers, the combination of a gas diffusion cell with an ion chromatograph (IC) plus subsequent direct spectrophotometric detection has proven to be one of the most convenient methods of sulfide analysis.This paper deals with the determination of sulfide anions via the coupling of a gas diffusion cell to an IC with subsequent spectrophotometric detection.
- AB-091Potentiometric analysis of brass and bronze plating baths
Methods are described for the potentiometric analysis of the following bath components:Brass plating bath: copper, zinc, free cyanide, ammonium, carbonate, and sulfite.Bronze plating bath: copper, tin, and free cyanide.
- AB-135Potentiometric determination of hydrogen sulfide, carbonyl sulfide, and mercaptans in petroleum products
This Bulletin describes the potentiometric determination of hydrogen sulfide, carbonyl sulfide, and mercaptans in gaseous and liquid products of the oil industry (natural gas, liquefied petroleum gas, used absorption solutions, distillate fuels, aviation gasoline, gasoline, kerosene, etc.). The samples are titrated with alcoholic silver nitrate solution using the Ag Titrode.
- AB-199Determination of sulfide and sulfite by polarography
Sulfide and sulfite can be determined polarographically without any problems. For sulfide, polarography is performed in an alkaline solution, for sulfite in a slightly acidic primary solution. The method is suitable for the analysis of pharmaceuticals (infusion solutions), wastewater/flue gas water, photographic solutions, etc.
- AN-CIC-023Halogens and sulfur in LPG according to ASTM D7994
ASTM D7994 - 17 describes the determination of fluorine, chlorine, and sulfur in liquefied petroleum gas (LPG) by oxidative pyrohydrolytic combustion followed by ion chromatography. A synthetic butane sample is analyzed. 50 µL of the sample is injected into the combustion system using the LPG Module. The combustion products are analyzed by IC applying intelligent Partial Loop Injection Technique after Inline Matrix Elimination.
- AN-H-042Standardization of thiosulfate titrant for copper determinations
This Application Note discusses the standardization of thiosulfate titrant for use in the determination of copper with thermometric titration.
- AN-I-008Sulfide content of wastewater
Determination of sulfide in wastewater by direct potentiometry with the Ag/S ion-selective electrode.
- AN-I-013Sulfide in ground and waste water
Even in low concentration, sulfide ions cause odor and corrosion problems in ground water and waste water. They can release hydrogen sulfide in acidified water, which is toxic in even minuscule amounts. This Application Note describes the determination of sulfide concentration in water via direct measurement with the Ag/S-ISE in accordance with ASTM D4658.
- AN-N-025Traces of nitrite, thiosulfate, and iodide using amperometric detection
Determination of traces of nitrite, thiosulfate, and iodide using anion chromatography with amperometric detection at the carbon paste electrode.
- AN-N-070Sulfide in effluent
Determination of sulfide in an effluent sample using anion chromatography with amperometric detection.
- AN-O-038Separation of various sulfur/nitrogen compounds using ion-pair chromatography
Determination of sulfite, nitrite, nitrate, sulfate, imidodisulfonate, and peroxodisulfate using ion-pair chromatography with conductivity detection after suppression.
- AN-P-051Cyanide and sulfide on Metrosep A Supp 10 - 100/2.0 using amperometric detection
The determination of cyanide and sulfide in the trace range requires an alkali eluent and amperometric detection. This Application Note describes a new column/eluent combination for optimized separation. The combination consists of the Metrosep A Supp 10 - 100/2.0 Microbore Column and a sodium hydroxide eluent that contains traces of EDTA for the complexation of the transition metals. This yields a better peak shape and detection limits below 0.05 µg/L.
- AN-P-052Trace analysis of cyanide and sulfide in aqueous samples – DC amperometric determination after ion chromatographic separation
Sulfide and cyanide are toxic anions. Their trace determination in any kind of water samples, especially in wastewater, is requied for safety reasons. However, metal traces present in the eluent can mask target anions due to complexation. The addition of a stronger complexing agent to the eluent mask these metal cations enabling interference free determaination. This application is mainly used for the analysis of cyanide and/or sulfide in water. However, it also fulfills the requirements of ASTM D2036 for the determination of total, amenable, weak acid dissociable cyanides. The determination of cyanide and sulfide require an alkaline eluent and amperometric detection. This Application Note describes a new column/eluent combination for optimized separation. The combination consists of the Metrosep A Supp 10 - 100/4.0 column and a sodium hydroxide eluent containing a trace of EDTA for transition metal complexation. This yields in better peak shape and detection limits below 0.1 μg/L.
- AN-P-059Sulfide in wastewater with Metrosep A Supp 10 - 100/4.0 and amperometric detection
Ion chromatographic determination of sulfide in wastewater is performed using amperometric detection and an alkali eluent to ensure the stability of the sulfide. Measurements are performed in single-potential or direct current (DC) amperometric mode. It is the best-known and most sensitive amperometric measuring method and also provides, in addition to a high selectivity, a large selection of working electrodes.Sulfide determination is performed on a Metrosep A Supp 10 - 100/4.0 type column; a silver electrode is used as the working electrode.
- AN-P-082Sulfite determination in food and beverages applying amperometric detection
Sulfite is found in many drinks, dried fruit, snacks etc. It acts as a preservative and may be added artificially or can be a side product of fermentation. As sulfite can induce a health risk, it is banned in raw foods and must be labeled on processed foods. Analysis of sulfite by IC with DC amperometric detection is nearly impossible due to the food matrix which fouls and deactivates the electrode surface very fast. The new automatic CV activation procedure (CV treatment, patent pending) cleans the electrode surface and recovers its sensitivity. This report shows DC amperometric detection of sulfite in several foodstuffs applying this activation step prior to the sulfite detection.
- AN-PAN-1001Online analysis of hydrogen sulfide and ammonia in sour water stripper
This Process Application Note details the simultaneous online analysis of H2S and NH3 in sour water which was previously treated in the sour water stripper (SWS). The method includes automatic cleaning and calibration. Fast and accurate results are continuously supplied for process control.
- AN-PAN-1004ABC Titration: Analysis of alkali, carbonate, hydroxide, and sulfide in pulping liquors
The Kraft process is the dominant pulping process in the pulp and paper industry with the highest chemical recovery efficiency. In order to run each part of the papermaking process optimally, constant quality checks and analyses should be performed. This Process Application Note illustrates the straightforward online analysis of alkali (active, effective, total titratable alkali (TTA)), carbonate, hydroxide, sulfide and the causticizing degree (CE%) in pulping liquors using a 2060 Process Analyzer from Metrohm Process Analytics.
- AN-PAN-1026Mercaptans and hydrogen sulfide in raw oil in accordance with ASTM D3227 and UOP163
Online mercaptan and H₂S monitoring with the 2060 TI Ex Proof Analyzer certified for Zone-1 and Zone-2 areas.
- AN-PAN-1035Online analysis of indigo, hydrosulfite, and other parameters in textile dye baths
The size of the indigo molecule makes it difficult to dye synthetic fibers, but the large pores of cellulose (such as in cotton) accept it readily. Indigo is insoluble in water, so it must first be reduced to the water-soluble leuco-indigo form by sodium hydrosulfite in a strong alkaline bath. Good circulation within the bath is imperative for consistent dye coverage, but care must be taken not to introduce any oxygen. Fabrics must be oxidized between dips in the dye bath in order to set the indigo within the pores of the fibers, but multiple dips are necessary for darker, uniform coverage. Many parameters need to be monitored and controlled to ensure high quality of the end product: the pH value for proper NaOH (alkali) dosage, the concentrations of both hydrosulfite and indigo, as well as the temperature of the bath and even the redox potential.
- AN-S-022Chloride, sulfite, and sulfate in a surfactant solution
Determination of chloride, sulfite, and sulfate in a surfactant solution using anion chromatography with conductivity detection after chemical suppression.
- AN-S-070Trace anions in wastewater (photographic industry) using amperometric detection
Determination of iodide and thiosulfate in photographic process wastewater using anion chromatography with amperometric detection at the carbon paste electrode after chemical suppression.
- AN-S-076Six anions in wastewater
Determination of fluoride, chloride, nitrate, sulfite, phosphate, and sulfate in wastewater using anion chromatography with conductivity detection after chemical suppression.
- AN-S-095Determination of sulfite in ginger powder using dialysis for sample preparation
Determination of sulfite in ginger powder using anion chromatography with conductivity detection after chemical suppression and dialysis for sample preparation.
- AN-S-100Nine anions in colored liquors
Determination of fluoride, chloride, nitrite, bromide, nitrate, phosphate, sulfite, sulfate, and thiosulfate in colored liquors using anion chromatography with conductivity detection after chemical suppression.
- AN-S-124Chlorite, chloride, sulfite, and oxalate in beer
Determination of chlorite, chloride, sulfite, and oxalate in beer using anion chromatography with conductivity detection after chemical suppression.
- AN-S-133Four anions in wastewater after inline removal of excess chloride
Determination of nitrite, nitrate, sulfite, and sulfate in wastewater containing high levels of chloride using anion chromatography with conductivity detection after chemical suppression and after inline chloride removal.
- AN-S-135Eight anions in river water
Determination of fluoride, chloride, nitrite, bromide, nitrate, phosphate, sulfite, and sulfate in river water using anion chromatography with conductivity detection after chemical suppression.
- AN-S-139Sulfite, oxalate, thiosulfate, and thiocyanate in the presence of standard anions
Determination of sulfite, oxalate, thiosulfate, and thiocyanate in the presence of fluoride, chloride, nitrite, bromide, nitrate, phosphate, and sulfate using anion chromatography with a high pressure gradient and conductivity detection after chemical suppression.
- AN-S-140Iodide, thiosulfate, and thiocyanate in the presence of standard anions
Determination of iodide, thiosulfate, and thiocyanate in the presence of fluoride, chloride, nitrite, bromide, nitrate, phosphate, and sulfate using anion chromatography with a high-pressure gradient and conductivity detection after chemical suppression.
- AN-S-144Heat stable salts in a scrubber solution
Determination of chloride, bromide, nitrate, sulfite, sulfate, phosphate, oxalate, thiosulfate, and thiocyanate (heat stable salts) in scrubber solutions using anion chromatography with conductivity detection after chemical suppression.
- AN-S-147Ten anions in an extract of explosives
Determination of chloride, nitrite, cyanate, azide, nitrate, chlorate, sulfate, thiocyanate, thiosulfate, and perchlorate in an extract of explosives using anion chromatography with conductivity detection after chemical suppression.
- AN-S-154Eleven anions with high pressure gradient elution
Determination of fluoride, chloride, nitrite, bromide, nitrate, phosphate, sulfate, oxalate, thiosulfate, iodide, and citrate in a standard solution using anion chromatography with a high pressure gradient and conductivity detection after chemical suppression.
- AN-S-155Sulfite, oxalate, and thiosulfate in the presence of standard anions in process water of the paper industry
Determination of chloride, bromide, nitrate, sulfite, sulfate, oxalate, and thiosulfate in a process water of the paper industry using anion chromatography with conductivity detection after chemical suppression.
- AN-S-178Five anions in lignin
Determination of chloride, sulfite, sulfate, oxalate, and thiosulfate in lignin using anion chromatography with conductivity detection after chemical suppression.
- AN-S-182Bromide and sulfur oxoanions in photographic developer solutions
Determination of bromide, sulfite, sulfate, and thiosulfate in a photographic developer solution using anion chromatography with conductivity detection after chemical suppression.
- AN-S-192Online determination of acids in an etching bath with inline dilution
Determination of fluoride, nitrate, phosphate, sulfite, and sulfate in an etching bath using anion chromatography with conductivity detection after chemical suppression.
- AN-S-201Eight anions separated on column Metrosep A Supp 1
Determination of formate, chloride, nitrite, phosphite, phosphate, sulfite, nitrate, and sulfate using anion chromatography with conductivity detection after chemical suppression.
- AN-S-225Sulfite in the presence of standard anions in beer on the column Metrosep A Supp 10 - 100/4.0
Determination of chloride, phosphate, sulfite, bromide, nitrate, and sulfate in a beer using anion chromatography with conductivity detection after chemical suppression.
- AN-S-226Sulfite, sulfate, and thiosulfate in metam potassium
Determination of chloride, sulfite, sulfate, and thiosulfate in metam potassium (potassium N-methyldithiocarbamate) using anion chromatography with conductivity detection after chemical suppression.
- AN-S-229Oxalate, thiosulfate, and thiocyanate in amines
Determination of oxalate, thiosulfate, and thiocyanate in an amine solution using anion chromatography with conductivity detection after chemical suppression.
- AN-S-238Sulfur species with «High–Low Detection»
Determination of sulfide, sulfite, sulfate, and thiosulfate in the presence of chloride, nitrate, and phosphate using anion chromatography with combination of suppressed and nonsuppressed conductivity detection.
- AN-S-248Chloride and sulfur species in pulp mill effluent by simultaneous conductivity and UV detection
Determination of chloride, sulfite, sulfate, and thiosulfate in a process water using anion chromatography with conductivity detection after chemical suppression and subsequent UV/VIS detection.
- AN-S-274Major anions in cooling lubricant after inline dialysis
Determination of chloride, nitrite, bromide, nitrate, phosphate, sulfite, sulfate, and oxalate in a cooling lubricant using anion chromatography with conductivity detection and subsequent UV detection (see AN-U-047) after sequential suppression and Metrohm Inline Dialysis.
- AN-S-279Perchlorate and thiosulfate separated on a guard column
Determination of perchlorate and thiosulfate using anion chromatography with conductivity detection after sequential suppression.
- AN-S-281Inorganic and organic anions in wine applying Inline Ultrafiltration
Product consistency and quality is of utmost importance to winemakers. This wine analysis evaluates nutrients and other ionic ingredients, which could potentially have deleterious effects on efficiency and production during the fermentation process. Inorganic and organic anions as acetate, chloride, phosphate, malate, sulfite, tartrate, sulfate, and oxalate are separated and quantified on a Metrosep A Supp 10 - 100/4.0 applying Inline Ultrafiltration and conductivity detection.
- AN-S-295Anions in boiler water including sulfur speciation (sulfite and sulfate)
Boiler water analysis is an important task in power plant applications. Under the given conditions, the "Metrosep A Supp 10 - 100/4.0" column separates sulfite and sulfate without any organic modifier in the eluent. Even without any stabilizer, sulfite can be determined with a high reproducibility.
- AN-S-305Determination of chlorate, thiosulfate, thiocyanate, and perchlorate in the presence of standard anions using a Dose-in Gradient
The Dose-in Gradient expands the standard IC system to a gradient system. Using isocratic elution for separating the oxyhalides and the anions containing sulfur is very time-consuming. An 800 Dosino and a T-piece are used to expand the isocratic system to a binary gradient system. This is shown in the example of the determination of the standard anions, in addition to chlorate, thiosulfate, thiocyanate, and perchlorate.
- AN-S-321Fast IC: Sulfite and sulfate in beer in less than ten minutes.
Fast IC means a high sample throughput. This is attained with short columns, relatively high flows and strong eluents. Sulfite can be determined in beer alongside sulfate and other anions with the Metrosep A Supp 10 - 50/4.0.
- AN-S-330Determination of metabisulfite as sulfite in pharmaceutical ointments
Sodium metabisulfite, also known as pyrosulfite, is used as a preservative and antioxidant in pharmaceutical products. Metabisulfite is not stable in aqueous solutions and quickly converts to sulfite. The peak in the chromatogram originates from the sulfite. This process is however calibrated using metabisulfite standard solutions, which is why the results are specified as sodium metabisulfite. This Application Note describes the determination of metabisulfite as sulfite in an ointment. It is dissolved in an aqueous solution containing formaldehyde to protect the sulfite against oxidation.
- AN-S-334Thiosulfate, thiocyanate and perchlorate in addition to standard anions using a low-pressure gradient
Retention of thiosulfate, thiocyanate and perchlorate is strong on the Metrosep A Supp 5 - 250/2.0 column. A shorter run time for the separation of the anions mentioned along with standard anions is achieved using a low-pressure gradient.
- AN-S-343Heat-stable salts in an MDEA scrubber solution
Hydrogen sulfide (H2S) and carbon dioxide (CO2) are disruptive byproducts of natural gas that must be eliminated during conveyance. This is accomplished with the aid of gas scrubbing, during which the gas flow is cleaned with absorbers such as alkanolamines or akylalkanolamines (e.g., methyldiethanolamine, MDEA). Reliable analysis is imperative, given that heat-stable salts often accumulate in the absorber and thus inhibit the absorption capacity for acid gases.The determination of heat-stable salts (SCN–, S2O32–, SO32–, SO42–, etc.) in MDEA solutions takes place on the Metrosep A Supp 5 - 250/4.0 column with conductivity detection following sequential suppression.Key words: amine gas treating, scrubber
- AN-S-381Phenylacetate in biogas production process
Food waste is an important raw material for biogas production. However, during the fermentation process, phenylacetate can be produced from phenylalanine. As phenylacetate inhibits bacterial growth and their metabolism, it is an important parameter to monitor in order to guarantee a successful fermentation process. Aside from phenylacetate, chloride, nitrate, sulfite, sulfate, phosphate, and thiosulfate are also determined in the fermentation broth sample.
- AN-S-389Heat-stable salts in monoethanolamine (MEA) for gas sweetening
In the petrochemical industry, natural gas is processed to remove contaminants and meet product specifications. Process contaminants include acidic gases such as hydrogen sulfide and carbon dioxide, which can corrode costly refinery equipment downstream. Typically, the acidic gases are removed via alkanolamine treatment using monoethanolamine (MEA) or methyldiethanolamine (MDEA). The amine solutions absorb the acidic gases, and then the amine compounds are removed from the natural gas. In addition to the acidic gases, heat stable salts (HSS) that remain in the natural gas are also corrosive to the treatment plants. These are also removed via gas sweetening and need to be determined in the used gas sweetening amine solution. Some typical heat stable salts of interest include acetate (1), formate (2), chloride (3), phosphate (4), sulfate (5), oxalate (6), thiosulfate (7), and thiocyanate (8).
- AN-S-390Sulfur species besides standard anions in process water
Process water from flue gas desulfurization mainly contains sulfite and sulfate. Besides these two main components, other sulfur species may be formed in the process. This application describes the determination of such late-eluting sulfur species with ion chromatography applying a Dose-in gradient. The applied gradient profile enables the resolution of amidosulfonate, dithionate, and imidodisulfonate besides thiosulfate, thiocyanate, major anions, and acetate.
- AN-S-395Forensic examination analysis with IC
Forensic institutes examine terrorist attacks and warfare agents via trace detection analysis of the used explosives and their residuals. Of particular importance is the acquisition of «chemical fingerprints» for criminal investigation departments and governmental security agencies. Institutes for public health and environmental protection analyze such compounds that can contaminate the underlying soil and infiltrate ground water.Forensic investigation with ion chromatography (IC) using suppressed conductivity detection allows a sensitive and robust determination of anionic contaminants such as chlorate, thiosulfate, thiocyanate, and perchlorate next to the common inorganic anions over a broad concentration range.
- AN-S-396Assessing wine quality with IC
Monitoring the range of organic acids in wine is crucial to improve flavor and quality, and to fulfill universal standardized criteria such as the International Code of Oenological Practices. Analytically, organic acids can be properly determined with ion chromatography (IC) and suppressed conductivity detection. As a multicomponent method, inorganic acids can also be resolved which are also valuable tracers for wine quality and taste. This Application Note presents two IC methods for wine quality analysis: a fast isocratic screening method of major organic acids and anions including sulfite, and a complex monitoring method with a binary gradient to separate 15 organic acids. Inline Ultrafiltration was used for economical sample treatment.
- AN-T-028Hydrogen sulfide and mercaptans in petroleum products
Simultaneous determination of hydrogen sulfide and mercaptans in petroleum products by potentiometric titration with silver nitrate using the Ag-Titrode.
- AN-T-032Sulfide and hydrogen sulfide in water
This Application Note presents a potentiometric titration method for trace H2S analysis in water on an OMNIS system using silver nitrate and an Ag Titrode.
- AN-T-211Fully automated wine analysis – Determination of free and total sulfurous acid, reductants, total acidity and pH value according to OIV
The analysis of the reductants, free and total sulfurous acid, pH and total acidity of wine can be performed fully automated on an OMNIS system based on the directive OIV-MA-AS323-04B, OIV-MA-AS313-01 and OIV-MA-AS313-15.Added components like SO2 have preserving properties and affect the microbiological environment (anti-microbacterial and enzyme-deactivating), they trap fermentation byproducts such as acetaldehyde and suppress a coloring into brown. The bound and free sulfurous acid are in an equilibrium with each other and can be determined via iodometric titration. Iodometric titration is also the method of choice to quantify other reductants, such as dyes, tanning agents, degradation products of carbohydrates and ascorbic acid. Finally, the acidity of wine is an important quality parameter, which affects the color and taste of wines. The total acidity and the pH of wine can be determined on the same system. Hence, Metrohm offers an all-in-one solution for the analysis of these mentioned key parameters.
- AN-T-222Sulfur dioxide content in traditional Chinese medicines
Traditional Chinese medicine (TCM) remedies are gaining popularity in other cultures. In some TCM, sulfur dioxide (SO2) is used as a preservative, antioxidant, and disinfectant. The products are treated by sulfurization with SO2 gas. However, sulfur dioxide is a very poisonous gas. Global health authorities have set strict limits for the content of SO2 in products. It is therefore of crucial importance to determine the sulfur dioxide content to comply with these limits. In this well-suited method, the SO2 content in different natural TCM products are analyzed reliably and accurately according to ISO 22590 using the Eco Titrator equipped with an Optrode and sodium hydroxide as titrant.
- AN-T-244Standardization of sodium thiosulfate
The OMNIS Titrator equipped with a Pt Titrode accurately and reliably determines titer concentration even in diluted titrants as shown in this Application Note.
- AN-U-031Sulfur species in process water of the paper industry by simultaneous conductivity and UV detection
Determination of sulfide and thiosulfate in a process water using anion chromatography with UV/VIS detection after chemical suppression and conductivity detection.
- AN-U-032Sulfide in a raw sodium vanadate solution by UV detection
Determination of sulfide in a raw vanadate solution using anion chromatography with UV/VIS detection.
- AN-U-038Sulfide in mining wastewater
Determination of sulfide in mining wastewater using anion chromatography with UV detection.
- AN-U-073Sulfur speciation in mining leachate by ion chromatography appling a perchlorate eluent and UV/VIS detection
In gold mining, there is a tendency to switch from cyanide leaching to the much less toxic thiosulfate leaching process. Thiosulfate leaching is a sensitive process that requires more optimization of the components of the leach reaction to maximize gold recovery and reagent loss. Sulfite, thiosulfate, thiocyanate, and tetrathionate are separated on a Metrosep A Supp 5 - 250/4.0 column. Perchlorate is choosen as an eluent as most of the metal perchlorates are soluble in water. This avoids metal precipitation in the IC System.
- AN-V-112Thiourea in nickel plating baths
Thiourea is determined by cathodic stripping voltammetry (CSV) at the HMDE in ammonia buffer at pH 8.9. Chloride in the sample does not interfere with this determination.
- EB-003Ion chromatography for food and beverage analysis
Efficiently analyze food products with ion chromatography (IC). Discover its robust applications in quality control for beverages, food additives, and dairy.
- WP-028Safety in Any Situation – Addressing the needs of first responders
Metrohm Raman presents a unique handheld materials identification system designed to meet the needs of defense and security professionals. Meet Mira DS, the most adaptable Raman analyzer available today. Mira DS was developed directly in response to requests from first responders in the field for a small, rugged, automated materialsidentification system that ensures the safety of the user in any situation.
- WP-065Simplified sulfite determination in foods and beverages using ion chromatography
Sulfites are well-known additives in foods and beverages used to extend shelf life and preserve colors. Such properties have led to the broad usage of sulfites in a range of foodstuffs like fruits, cereals, vegetables, seafood, juices, alcoholic and non-alcoholic (soft) beverages, and in some meat products. The term «sulfites» describes a group of molecules that include sulfur dioxide (SO2) and chemically related molecules like sodium sulfite (Na2SO3), sodium bisulfite (NaHSO3), or sodium metabisulfite (Na2S2O5). Sulfite intake has been correlated with several adverse reactions, and therefore sulfites are included in the FAO/WHO Codex Alimentarius list. Labelling sulfite content in foods and beverages is necessary when the total concentration exceeds 10 mg/kg. Metrohm ion chromatography allows the reliable measurement of sulfite in different matrices using either conductivity or amperometric detection. The inclusion of automated sample preparation and cleaning steps with Metrohm instrumentation saves additional analyst time and helps increase sample throughput.
- WP-066An introduction to ion chromatography mass spectrometry (IC-MS)
Ion chromatography mass spectrometry (IC-MS) is a powerful tool that can handle many challenging analytical tasks which cannot be performed adequately by IC alone. IC-MS is a robust, sensitive, and selective technique used for the determination of polar contaminants like inorganic anions, organic acids, haloacetic acids, oxyhalides, or alkali and alkaline earth metals. After separation of the sample components via IC, mass selective detection guarantees peak identity with low detection limits. The inclusion of automated Metrohm Inline Sample Preparation (MISP) allows not only water samples, but also chemicals, organic solvents, or post-explosion residues to be readily analyzed without need for extensive manual laboratory work. This White Paper explains the benefits of IC-MS over IC in certain cases, the hyphenation of IC and different MS systems, as well as related norms and standards.