851 Titrando with generator electrode with diaphragm

851 Titrando with generator electrode with diaphragm
Beställningsnummer: 2.851.0010

Coulometer including generator electrode with diaphragm and 801 Magnetic Stirrer.

Coulometry is the ideal method for water determination in liquids, solids and gases when it comes to water determination in the trace range (10 µg to 10 mg absolute water). In addition, coulometry is an absolute method and thus no titer determination is necessary.

Coulometric titrations are carried out easily and quickly with the 851 Titrando.

Recommended measuring range: 10 µg - 200 mg absolute water

  • Dokument
  • Ingående delar och tillbehör
  • Alternativ
  • Brochure: 851 Titrando / 852 Titrando (english)
    • 中文产品手册:851 Titrando / 852 Titrando (中文)
    • Prospectus : 851 Titrando / 852 Titrando (français)
    • Prospekt: 851 Titrando / 852 Titrando (deutsch)
  • Brochure: Food Analysis - Quality control in the food and beverage industry (english)
    • Prospectus: Analyse agroalimentaire - Le contrôle qualité dans l’industrie des aliments et des boissons (français)
    • Prospekt: Lebensmittelanalytik - Qualitätskontrolle von Nahrungsmittel (deutsch)
    • Folleto: Análisis de alimentos - Control de calidad en la industria de alimentos y bebidas (español)
  • Declaration of conformity 851 Titrando, English (english)
  • Manual for 851 Titrando (english)
    • Mode d’emploi 851 Titrando (français)
    • Handbuch 851 Titrando (deutsch)
    • Manual 851 Titrando (español)
  • Release Notes for 5.851.0012 - 5.852.0012 Titrando (english)

Ladda ner hela leveransomfattningen och extra tillbehör som PDF

  • Double Pt-wire electrode for coulometry
    6.0341.100
    Double Pt-wire electrode for coulometry

    Indicator electrode used for coulometric Karl Fischer titration.

    1 piece(s)

  • Generator electrode with diaphragm
    6.0344.100
    Generator electrode with diaphragm

    Generator electrode with diaphragm for coulometric Karl Fischer titrations, SGJ 29/22.
    This generator electrode is well suited for:
     

    • samples with very low absolute water contents < 50 ppm
    • coulometric water content determination in oil samples
    • applications where ketone reagents are used
    • applications where low-conducting reagents are used (addition of chloroform, xylene >10%)

    1 piece(s)

  • KF adsorber tube for coulometer cell
    6.1403.030
    KF adsorber tube for coulometer cell

    For KF coulometers.


    1 piece(s)

  • SGJ stopper SGJ 14
    6.1437.000
    SGJ stopper SGJ 14

    1 piece(s)

  • Stopper / B-14/15 / M10
    6.1446.060
    Stopper / B-14/15 / M10

    1 piece(s)

  • Septum 16 mm, 5 pieces
    6.1448.020
    Septum 16 mm, 5 pieces
    Set of 5 pcs.

    2 piece(s)

  • KF titration vessel / 80-250 mL / coulometric
    6.1464.320
    KF titration vessel / 80-250 mL / coulometric

    1 piece(s)

  • Stirring bar / 25 mm
    6.1903.030
    Stirring bar / 25 mm

    Stirring bar with magnetic core, PTFE covering, length 25 mm.


    1 piece(s)

  • Support stand without support rod
    6.2001.060
    Support stand without support rod
    To attach an 801, 804, 803 Stirrer to a Titrando, Titrino plus, Dosimat plus or 856 and 867.

    1 piece(s)

  • Clamping ring
    6.2013.010
    Clamping ring

    For support rods with a diameter of 10 mm.


    1 piece(s)

  • Support rod / 250 mm
    6.2016.030
    Support rod / 250 mm

    1 piece(s)

  • Holding clip for bottles
    6.2043.005
    Holding clip for bottles

    Holding spring for reagent bottles in exchange units.


    2 piece(s)

  • Titration vessel holder
    6.2047.020
    Titration vessel holder
    Titration vessel holder for coulometric cells.Used with 756, 831 KF Coulometer

    1 piece(s)

  • Adapter red  2 mm plug / 4 mm socket
    6.2103.130
    Adapter red 2 mm plug / 4 mm socket
    For connecting plug B (4 mm) to 2 mm socket.

    1 piece(s)

  • Adapter black 2 mm plug / B socket 4 mm
    6.2103.140
    Adapter black 2 mm plug / B socket 4 mm
    For connecting plug B (4 mm) to 2 mm socket.

    1 piece(s)

  • Electrode cable / 1 m / F
    6.2104.020
    Electrode cable / 1 m / F
    For connecting electrodes with Metrohm plug-in head G to Metrohm instruments (socket F).

    1 piece(s)

  • Electrode cable / 1 m / H
    6.2104.120
    Electrode cable / 1 m / H
    With plug H. For connecting generator electrode - KF Coulometer.

    1 piece(s)

  • 
    GL 18 screw cap with hole
    6.2701.040
    GL 18 screw cap with hole
    Made of PBT. With a hole for the 6.1448.020 septum. For the 6.5405.000 cell without diaphragm and the 6.1464.32X and 6.1465.320 titration vessels.

    1 piece(s)

  • Sleeve
    6.2713.000
    Sleeve

    For the fat-free ground-joint connection with the standard ground-joint SGJ 14.


    3 piece(s)

  • Sleeve
    6.2713.010
    Sleeve

    Sleeve for the fat-free ground-joint connection with the standard ground-joint SGJ 29.


    1 piece(s)

  • Sleeve
    6.2713.020
    Sleeve

    For the fat-free ground-joint connection with the standard ground-joint SGJ 19.


    1 piece(s)

  • Stopper
    6.2730.030
    Stopper

    Complete with nipple and O-ring. For 6.1414.030 titration vessel lids. For KF instruments, VA measurement stands, VA Computrace and IC Dilution.

    1 piece(s)

  • Funnel
    6.2738.000
    Funnel

    For the KF coulometer.


    1 piece(s)

  • Molecular sieve
    6.2811.000
    Molecular sieve
    Molecular sieve. Bottle containing 250 g. Pore size: 0.3 nm. Without moisture indicator. For Rancimats and Karl Fischer instruments.

    1 piece(s)

  • Needle with Luer connector
    6.2816.030
    Needle with Luer connector

    Needle for filling in mercury into the Multi-Mode Electrode and for sample addition in Karl Fischer titration.


     


    2 piece(s)

  • Syringe 5 mL
    6.2816.090
    Syringe 5 mL

    5 mL syringe made of PP, with Luer connector.


    2 piece(s)

Ladda ner hela leveransomfattningen och extra tillbehör som PDF

  • Tiamo 2.5 Light CD: 1 license
    6.6056.251
    Tiamo 2.5 Light CD: 1 license

    tiamo™ 2.5 Light computer program for controlling a titration system.

    • Up to two Metrohm instruments (Titrino, Titrando, etc.) can be connected; balances and other generic (i.e. non-Metrohm) instruments can be included without limitation
    • Graphical method editor with numerous templates
    • Layout manager for individual monitor interface
    • Professional database with reevaluation
    • High-performance report generator
    • Data export as PDF file, CSV, SLK
    • No parallel titration
    • No data export in XML format for LIMS
    • Dialog languages: German, English, French, Italian, Spanish, Czech, Portuguese, Polish, Russian, Slovakian, Japanese, Chinese, Traditional Chinese

     

  • Tiamo 2.5 Full CD: 1 license
    6.6056.252
    Tiamo 2.5 Full CD: 1 license

    Computer program for controlling complex titration systems.

    • Graphical method editor with numerous templates
    • Layout manager for individual monitor interface
    • Professional database with reevaluation
    • Export to LIMS, NuGenesis, Cyberlab, etc.
    • High-performance report generator
    • In compliance with the directives according to FDA 21 CFR Part 11
    • Parallel titration
    • Dialog languages: German, English, French, Italian, Spanish, Portuguese, Polish, Russian, Slovakian, Czech, Japanese, Chinese and Traditional Chinese

     

  • tiamo 2.5 Multi CD: 3 licenses
    6.6056.253
    tiamo 2.5 Multi CD: 3 licenses

    Client/server-compatible computer program for controlling complex titration systems.

    • Graphical method editor with numerous templates
    • Layout manager for individual monitor interface
    • Client/server database
    • Professional database with reevaluation
    • Export to LIMS, NuGenesis, Cyberlab, etc.
    • High-performance report generator
    • In compliance with the directives according to FDA 21 CFR Part 11
    • Parallel titration
    • Dialog languages: German, English, French, Italian, Spanish, Czech, Portuguese, Polish, Russian, Slovakian, Japanese, Chinese and Traditional Chinese