Metrosep A Supp 7 - 150/2.0

Metrosep A Supp 7 - 150/2.0
Beställningsnummer: 6.1006.640

The Metrosep A Supp 7 - 150/2.0 is the shorter of the two A Supp 7 columns in the microbore version. With the Metrosep A Supp 7 - 150/2.0, these ions are determined with certainty and precision down to the lower µg/L range.

The high detection sensitivity is achieved through the use of the 5 µm polyvinyl alcohol polymer, with which extremely high plate numbers and thus outstanding separation and detection properties are achieved. In addition, the separation can be adapted to the specific requirements of the application by modifying the temperature.
This microbore column is particularly suitable for use with an MS detector.

  • Tekniska specifikationer
  • Dokument
  • Alternativ
  • Kromatogram
Carrier material Polyvinyl alcohol with quarternary ammonium groups
Column capacity 18 µmol (Cl)
Column dimensions 150 x 2.0 mm
Eluents Carbonate eluent (standard eluent)

Sodium carbonate: 3.6 mmol/L; 763 mg/2 L
(column temperature: 45 °C)
Housing material PEEK
Max. pressure 20 MPa
Maximum flow 0.6 mL/min
Organic modifier 0 - 100% (particularly acetone, acetonitrile and methanol)
Particle size 5 µm
pH range 3...12
Standard flow 0.2 mL/min
Standard temperature 45 °C
Temperatur range 20...60 °C

Ladda ner hela leveransomfattningen och extra tillbehör som PDF

  • Metrosep A Supp 5 Guard/2.0
    6.1006.600
    Metrosep A Supp 5 Guard/2.0

    The Metrosep A Supp 5 Guard/2.0 reliably protects the 2 mm versions of the Metrosep A Supp 5 and Metrosep A Supp 7 IC anion columns against contamination from the sample or eluent.
    It contains the same separation material as the Metrosep A Supp 5, is also made of PEEK, and is screwed directly onto the respective separation column with nearly no dead volume ("On Column Guard System"). The guard column prolongs the service life of the analytical column, with practically no influence on its chromatographic separating efficiency. The economical price and simple handling make using the A Supp 5 Guard/2.0 highly recommended.

  • Metrosep A Supp 5 S-Guard/2.0
    6.1006.610
    Metrosep A Supp 5 S-Guard/2.0

    The Metrosep A Supp 5 S-Guard/2.0 reliably protects the 2 mm versions of the Metrosep A Supp 5 and Metrosep A Supp 7 IC anion columns against contamination from the sample or eluent.
    It contains the same separation material as the Metrosep A Supp 5, is also made of PEEK, and is connected directly onto the respective separation column by means of capillary connection. The guard column prolongs the service life of the analytical column, with practically no influence on its chromatographic separating efficiency. The economical price and simple handling make using the A Supp 5 S-Guard/2.0 highly recommended.

  • Metrosep A Supp 16 Guard/2.0
    6.1031.600
    Metrosep A Supp 16 Guard/2.0


    The Metrosep A Supp 16 Guard/2.0 reliably protects the Metrosep A Supp 16 analytical separation column with 2 mm inner diameter against contamination. Thanks to the "On Column Guard System", the guard column is very easy to handle. The guard column screws easily and directly onto the analytical column. No tools are required.


  • Metrosep A Supp 16 S-Guard/2.0
    6.1031.610
    Metrosep A Supp 16 S-Guard/2.0


    The Metrosep A Supp 16 S-Guard/2.0 reliably protects the Metrosep A Supp 16 analytical separation column with 2 mm inner diameter against contamination. The guard column is connected to the separation column simply using capillary connections. No tools are required.