Disinfection byproducts from water treatment are suspected not only of being health hazards but even of being carcinogenic. Oxyhalides have therefore become the subject of many investigations and standards (e.g., EPA 300.1 Part B, EPA 317.0, EPA 326.0). Of primary concern is bromate, which forms from bromide during the ozonization of drinking water. The Metrosep A Supp 7 - 250/4.0 is a high-performance separation column for the parallel determination of standard anions, oxohalides and dichloroacetic acid. With this column, these ions are determined with certainty and precision down to the lower µg/L range. The high detection sensitivity is achieved through the use of the 5 µm polyvinyl alcohol polymer, with which extremely high plate numbers and thus outstanding separation and detection properties are achieved. In addition, the separation can be adapted to the specific requirements of the application by modifying the temperature.

  • Tekniska specifikationer
  • Dokument
  • Applikationer
  • Alternativ
  • Kromatogram
Carrier material Polyvinyl alcohol with quarternary ammonium groups
Column capacity 110 µmol (Cl)
Column dimensions 250 x 4.0 mm
Eluents

Carbonate eluent (standard eluent)

Sodium carbonate: 3.6 mmol/L; 763 mg/2 L
(column temperature: 45 °C)

Carbonate eluent, modified

Sodium carbonate: 3.6 mmol/L; 763 mg/2 L
Acetone: 2%; 40 mL/2 L
(column temperature: 45 °C)
Housing material PEEK
Max. pressure 15 MPa
Maximum flow 1.0 mL/min
Organic modifier 0 - 100% (particularly acetone, acetonitrile, methanol)
Particle size 5 µm
pH range 3...12
Standard flow 0.7 mL/min
Temperatur range 20...60 °C

Ladda ner hela leveransomfattningen och extra tillbehör som PDF

  • Metrosep A SUPP 5 Guard/4.0
    6.1006.500
    Metrosep A SUPP 5 Guard/4.0

    The Metrosep A Supp 5 Guard/4.0 reliably protects the Metrosep A Supp 5 and 7 IC anion columns against contamination from the sample or the eluent.

    It contains the same separation material as the Metrosep A Supp 5, is also made of PEEK, and is screwed directly onto the respective separation column with nearly no dead volume ("On Column Guard System"). The guard column prolongs the service life of the analytical column, with practically no influence on its chromatographic separating efficiency. The economical price and simple handling make using the A Supp 5 Guard/4.0 highly recommended.

  • Metrosep A Supp 5 S-Guard/4.0
    6.1006.540
    Metrosep A Supp 5 S-Guard/4.0

    The Metrosep A Supp 5 S-Guard/4.0 reliably protects the Metrosep A Supp 5 and 7 IC anion columns against contamination from the sample or eluent.

  • Metrosep RP 2 Guard/3.5
    6.1011.030
    Metrosep RP 2 Guard/3.5
    General guard column. For Metrosep Anion Dual 2 and Dual 3 in particular.
  • Spare filter for RP Guard, 10 pieces
    6.1011.120
    Spare filter for RP Guard, 10 pieces
  • Spare filter for RP 2 Guard/3.5, 10 pieces
    6.1011.130
    Spare filter for RP 2 Guard/3.5, 10 pieces
  • Metrosep A Supp 16 Guard/4.0
    6.1031.500
    Metrosep A Supp 16 Guard/4.0


    The Metrosep A Supp 16 Guard/4.0 reliably protects the Metrosep A Supp 16 analytical separation column against contamination. Thanks to the "On Column Guard System", the guard column is very easy to handle. The guard column screws easily and directly onto the analytical column. No tools are required.


  • Metrosep A Supp 16 S-Guard/4.0
    6.1031.510
    Metrosep A Supp 16 S-Guard/4.0


    The Metrosep A Supp 16 S-Guard/4.0 reliably protects the Metrosep A Supp 16 analytical separation column against contamination. The guard column is connected to the separation column simply using capillary connections. No tools are required.