Ag/AgCl reference electrode (length 16.2 cm)

Ag/AgCl reference electrode (length 16.2 cm)
Beställningsnummer: 6.0729.110

Silver / silver chloride reference system shielded with titanium shield with double junction system, installation length 13.8 cm.
This reference electrode is well suited for:

  • automated applications
  • non-aqueous samples
  • differential potentiometry

The SGJ 14/15 enables easy assembly and the flexible ground-joint diaphragm, which is insensitive to contamination, can be easily replaced. The reference and bridge electrolyte can be freely selected according to the application and are easy to exchange. This sensor is delivered without electrolyte filling.

  • Tekniska specifikationer
  • Dokument
  • Applikationer
  • Ingående delar och tillbehör
  • Alternativ
Bridge electrolyte type variable
Diaphragm Ground-joint diaphragm
Electrode plug-in head Metrohm plug-in head G
Electrolyte outflow (µL/h) with reference to 3 mol/L KCl 5...50
Max. installation length (mm) 138
Min. immersion depth (mm) 10
Reference electrolyte type variable
Reference resistance (kΩ) with reference to 3 mol/L KCl <3
Reference system Ag wire/AgCl
SGJ sleeve Standard ground-joint 14/15
Shaft diameter bottom (mm) 12
Shaft diameter top (mm) 12
Shaft material Glass
Temperature range, long-term (°C) 0 ... 80
Temperature range, short-term (°C) 0 ... 80

Ladda ner hela leveransomfattningen och extra tillbehör som PDF

  • Sleeve with SGJ 14/12 mm
    6.1236.050
    Sleeve with SGJ 14/12 mm
    Sleeve with SGJ 14/12 mm, polyethylene.

    1 piece(s)

  • 
            
    Storage vessel
            
     
    6.2008.040
    Storage vessel  


    Together with 6.2008.050 storage vessel holder provides a support for the electrode on 6.3032.XXX dosing units.


    1 piece(s)

Ladda ner hela leveransomfattningen och extra tillbehör som PDF

  • Diaphragm for reference electrode
    6.1243.030
    Diaphragm for reference electrode
    Spare ground-joint diaphragm for 6.0726.1XX and 6.0729.1XX reference electrodes
  • Electrode cable / 1 m / F
    6.2104.020
    Electrode cable / 1 m / F
    For connecting electrodes with Metrohm plug-in head G to Metrohm instruments (socket F).
  • Differential amplifier, plug F
    6.2129.010
    Differential amplifier, plug F

    Differential amplifier with plug F, for Titrandos. Power supply to be ordered seperately

    6.2117.000 Power supply 230 V

    6.2119.000 Power supply 115 V

  • Electrolyte  3 mol/L KCl (250 mL)
    6.2308.020
    Electrolyte 3 mol/L KCl (250 mL)
    Electrolyte solution c(KCl) = 3 mol/L, (for Ag/AgCl reference systems)
  • Electrolyte KNO3-1mol/L 250 mL
    6.2310.010
    Electrolyte KNO3-1mol/L 250 mL
    Electrolyte solution KNO3 1 M (reference electrolyte for combined silver electrodes)
  • TEABr 0.4 mol/L in ethylene glycol (250 mL)
    6.2320.000
    TEABr 0.4 mol/L in ethylene glycol (250 mL)
    Electrolyte solution TEABr (tetraethylammonium bromide in ethylene glycol), c(TEABr) = 0.4 mol/L