Separate Pt ring electrode

Separate Pt ring electrode
Beställningsnummer: 6.0351.100

This platinum ring electrode has to be used in combination with a reference electrode (c(KCl) = 3 mol/L as reference electrolyte) and is well suited for:
 

  • redox titrations, e.g. iodometry or cerimetry
  • auxiliary electrode for differential potentiometry
  • Tekniska specifikationer
  • Dokument
  • Applikationer
  • Ingående delar och tillbehör
  • Alternativ
Electrode plug-in head Metrohm plug-in head G
Indicator electrode shape Ring
Indicator electrode type Pt
Max. installation length (mm) 125
Measuring range –2000 ... 2000
Measuring unit mV
Min. immersion depth (mm) 7
pH range 0 ... 14
SGJ sleeve Flexible SGJ sleeve
Shaft diameter bottom (mm) 12
Shaft diameter top (mm) 12
Shaft material Glass
Temperature range, long-term (°C) –20 ... 80
Temperature range, short-term (°C) –20 ... 80

Ladda ner hela leveransomfattningen och extra tillbehör som PDF

  • Sleeve with SGJ 14/12 mm
    6.1236.050
    Sleeve with SGJ 14/12 mm
    Sleeve with SGJ 14/12 mm, polyethylene.

    1 piece(s)

  • 
            
    Storage vessel
            
     
    6.2008.040
    Storage vessel  


    Together with 6.2008.050 storage vessel holder provides a support for the electrode on 6.3032.XXX dosing units.


    1 piece(s)

Ladda ner hela leveransomfattningen och extra tillbehör som PDF

  • Ag/AgCl reference electrode (length 12.5 cm)
    6.0726.100
    Ag/AgCl reference electrode (length 12.5 cm)

    Silver/silver chloride reference electrode with Double-Junction System, installation length 10 cm.
    The standard ground-joint 14/15 enables easy assembly, and the flexible ground-joint diaphragm, which is insensitive to contamination, can be replaced at any time. The reference electrolyte and the bridge electrolyte can be selected freely according to use, and are easy to replace. This sensor is supplied without electrolyte filling.

  • LL ISE reference electrode
    6.0750.100
    LL ISE reference electrode

    Silver / silver chloride reference electrode with double junction system.
    This reference electrode is well suited for:

    • automated applications
    • ion measurements
    • surfactant titrations

    The ground-joint diaphragm, which is insensitive to contamination, offers a constant and reproducible electrolyte outflow. Additionally, the reference electrolyte is gelified for even better signal stability. The sensor is delivered with c(KCl) = 3 mol/L as bridge electrolyte, which can be freely selected and exchanged as needed.

  • Electrode cable / 1 m / F
    6.2104.020
    Electrode cable / 1 m / F
    For connecting electrodes with Metrohm plug-in head G to Metrohm instruments (socket F).
  • Electrolyte  3 mol/L KCl (250 mL)
    6.2308.020
    Electrolyte 3 mol/L KCl (250 mL)
    Electrolyte solution c(KCl) = 3 mol/L, (for Ag/AgCl reference systems)