Metrosep Carb 2 - 250/2.0

Metrosep Carb 2 - 250/2.0
Beställningsnummer: 6.01090.230

The Metrosep Carb 2 - 250/2.0 IC column is particularly suitable for the determination of carbohydrates using alkaline eluents and pulsed amperometric detection. The high-capacity anion exchanger column is based on a styrol-divinylbenzene copolymer. It is stable in the range of pH = 0 to pH = 14 and separates monosaccharides and disaccharides. It is also suitable for the analysis of sugar alcohols, anhydrous sugars, amino sugars, etc. The 250 mm Microbore version of the Metrosep Carb 2 separation column is optimized for complex separations.

Thanks to its low eluent consumption, it is particularly suitable for IC-MS coupling.

  • Tekniska specifikationer
  • Dokument
  • Ingående delar och tillbehör
  • Alternativ
  • Kromatogram
Carrier material Polystyrene-divinylbenzene copolymer with quaternary ammonium groups
Column dimensions 250 x 2.0 mm
Eluents Hydroxide acetate eluent (standard eluent)

Sodium hydroxide (c = 20 mol/L): 100 mmol/L; 10 mL/2 L
Sodium acetate: 10 mmol/L; 1,640.7 mg/2 L
Housing material PEEK
Max. pressure 20 MPa
Maximum flow 0.30 mL/min
Organic modifier In the eluent: 0 - 50% acetonitrile or methanol
In the sample: 0 - 100% acetone, acetonitrile or methanol
Particle size 5.0 µm
pH range 0...14
Standard flow 0.13 mL/min
Standard temperature 30 °C
Temperatur range 20...60 °C

Ladda ner hela leveransomfattningen och extra tillbehör som PDF

  • Threaded stopper
    6.2744.060
    Threaded stopper

    For UNF 10/32. Stopper for IC, e.g. for the sealing of columns.


    2 piece(s)

Ladda ner hela leveransomfattningen och extra tillbehör som PDF

  • Metrosep Carb 2 Guard/2.0
    6.01090.600
    Metrosep Carb 2 Guard/2.0

    The Metrosep Carb 2 Guard/2.0 microbore guard column effectively removes contaminations, thus protecting the analytical separation column. The design of the guard column has been selected in such a way that its influence on the chromatographic separation can be ignored.

  • Metrosep Carb 2 S-Guard/2.0
    6.01090.610
    Metrosep Carb 2 S-Guard/2.0

    The Metrosep Carb 2 S-Guard/2.0 microbore guard column effectively removes contaminations, thus protecting the analytical separation column. The design of the guard column has been selected in such a way that its influence on the chromatographic separation can be ignored.

  • PEEK capillary, 0.18 mm ID / 2 m
    6.01806.000
    PEEK capillary, 0.18 mm ID / 2 m

    Preheating capillary for Metrosep Carb 2 columns in the 2 mm version (6.01090.2x0).

  • Metrosep BO33- Trap 1 - 100/4.0
    6.1015.200
    Metrosep BO33- Trap 1 - 100/4.0

    Trap column for the removal of borate contaminants from the eluent. The Metrosep CO32- Trap 1 - 100/4.0 is used mainly in carbohydrate analysis with hydroxide eluents.

  • Metrosep CO32- Trap 1 - 100/4.0
    6.1015.300
    Metrosep CO32- Trap 1 - 100/4.0

    Trap column for the removal of carbonate traces in hydroxide eluents.