852 Titrando with Touch Control and generator electrode without diaphragm

852 Titrando with Touch Control and generator electrode without diaphragm
Beställningsnummer: 2.852.0160

Coulometer including generator electrode without diaphragm, complete volumetric titration cell and Touch Control.

Coulometry is the ideal method for water determination in liquids, solids and gases when it comes to water determination in the trace range (10 µg to 10 mg absolute water). In addition, coulometry is an absolute method and thus no titer determination is necessary.

Recommended coulometry measuring range: 10 µg - 200 mg absolute water

The 852 Titrando controls not only coulometric, but also volumetric Karl Fischer titration.

  • Dokument
  • Ingående delar och tillbehör
  • Alternativ

Ladda ner hela leveransomfattningen och extra tillbehör som PDF

  • Double Pt-wire electrode for volumetry
    6.0338.100
    Double Pt-wire electrode for volumetry

    Indicator electrode used for volumetric Karl Fischer titration.

    1 piece(s)

  • Double Pt-wire electrode for coulometry
    6.0341.100
    Double Pt-wire electrode for coulometry

    Indicator electrode used for coulometric Karl Fischer titration.

    1 piece(s)

  • Generator electrode without diaphragm
    6.0345.100
    Generator electrode without diaphragm

    Generator electrode without diaphragm for coulometric Karl Fischer titrations, SGJ 29/22.
    This generator electrode is well suited for most applications where the sample is highly soluble in alcohol.

    1 piece(s)

  • Set of seals
    6.1244.040
    Set of seals

    Set of seals for 6.1414.030. The set is comprised of one seal and various O-rings.

    1 piece(s)

  • KF adsorber tube for coulometer cell
    6.1403.030
    KF adsorber tube for coulometer cell

    For KF coulometers.


    1 piece(s)

  • KF Adsorber tube
    6.1403.040
    KF Adsorber tube
    Used with KF equipment. Including cover and O-ring.

    1 piece(s)

  • KF titration vessel lid
    6.1414.030
    KF titration vessel lid
    For volumetric KF titrations.

    1 piece(s)

  • Titration vessel / 20-90 mL
    6.1415.220
    Titration vessel / 20-90 mL

    1 piece(s)

  • Titration vessel / 50-150 mL
    6.1415.250
    Titration vessel / 50-150 mL

    1 piece(s)

  • SGJ stopper SGJ 14
    6.1437.000
    SGJ stopper SGJ 14

    1 piece(s)

  • Stopper / B-14/15 / M10
    6.1446.060
    Stopper / B-14/15 / M10

    1 piece(s)

  • Septum 12 mm, 5 pieces
    6.1448.010
    Septum 12 mm, 5 pieces
    Set of 5 items.

    2 piece(s)

  • Septum 16 mm, 5 pieces
    6.1448.020
    Septum 16 mm, 5 pieces
    Set of 5 pcs.

    2 piece(s)

  • KF titration vessel / 80-250 mL / coulometric
    6.1464.320
    KF titration vessel / 80-250 mL / coulometric

    1 piece(s)

  • Stirring bar / 16 mm
    6.1903.020
    Stirring bar / 16 mm
    Stirring Bar with magnetic core, PTFE coated, length 16 mm

    2 piece(s)

  • Stirring bar / 25 mm
    6.1903.030
    Stirring bar / 25 mm

    Stirring bar with magnetic core, PTFE covering, length 25 mm.


    3 piece(s)

  • Base plate on both sides
    6.2001.090
    Base plate on both sides
    Double stand for attaching 2 x 801, 803, 804 to a Titrando

    1 piece(s)

  • Clamping ring
    6.2013.010
    Clamping ring

    For support rods with a diameter of 10 mm.


    2 piece(s)

  • Support rod / 250 mm
    6.2016.030
    Support rod / 250 mm

    2 piece(s)

  • Holding clip for bottles
    6.2043.005
    Holding clip for bottles

    Holding spring for reagent bottles in exchange units.


    2 piece(s)

  • Titration vessel holder
    6.2047.020
    Titration vessel holder
    Titration vessel holder for coulometric cells.Used with 756, 831 KF Coulometer

    1 piece(s)

  • Adapter red  2 mm plug / 4 mm socket
    6.2103.130
    Adapter red 2 mm plug / 4 mm socket
    For connecting plug B (4 mm) to 2 mm socket.

    2 piece(s)

  • Adapter black 2 mm plug / B socket 4 mm
    6.2103.140
    Adapter black 2 mm plug / B socket 4 mm
    For connecting plug B (4 mm) to 2 mm socket.

    2 piece(s)

  • Electrode cable / 1 m / F
    6.2104.020
    Electrode cable / 1 m / F
    For connecting electrodes with Metrohm plug-in head G to Metrohm instruments (socket F).

    2 piece(s)

  • Electrode cable / 1 m / H
    6.2104.120
    Electrode cable / 1 m / H
    With plug H. For connecting generator electrode - KF Coulometer.

    1 piece(s)

  • 
    Weighing boats
    6.2412.000
    Weighing boats

    Weighing boat made of glass for the 6.1414.030 titration vessel lid or the 6.1455.31X, 6.1464.32X, 6.1465.320 titration vessel. For KF water determinations. Including protective tube.


    1 piece(s)

  • 
    GL 18 screw cap with hole
    6.2701.040
    GL 18 screw cap with hole
    Made of PBT. With a hole for the 6.1448.020 septum. For the 6.5405.000 cell without diaphragm and the 6.1464.32X and 6.1465.320 titration vessels.

    1 piece(s)

  • Sleeve
    6.2713.000
    Sleeve

    For the fat-free ground-joint connection with the standard ground-joint SGJ 14.


    3 piece(s)

  • Sleeve
    6.2713.010
    Sleeve

    Sleeve for the fat-free ground-joint connection with the standard ground-joint SGJ 29.


    1 piece(s)

  • Sleeve
    6.2713.020
    Sleeve

    For the fat-free ground-joint connection with the standard ground-joint SGJ 19.


    1 piece(s)

  • Screw nipple
    6.2730.010
    Screw nipple
    Made of PP. For 6.1448.010 Septum or for mounting 6.1403.040 Drying tube or 6.0338.100 Electrode in 6.1414.030 and 6.1414.040 KF Titration vessel lids. Used for KF titrations.

    2 piece(s)

  • Septum stopper
    6.2730.020
    Septum stopper
    With E.301.0041 O-ring. For 6.1448.010 Septum and 6.1414.030 Titration vessel lid. Used for KF applications.

    1 piece(s)

  • Stopper
    6.2730.030
    Stopper

    Complete with nipple and O-ring. For 6.1414.030 titration vessel lids. For KF instruments, VA measurement stands, VA Computrace and IC Dilution.

    4 piece(s)

  • Funnel
    6.2738.000
    Funnel

    For the KF coulometer.


    1 piece(s)

  • Molecular sieve
    6.2811.000
    Molecular sieve
    Molecular sieve. Bottle containing 250 g. Pore size: 0.3 nm. Without moisture indicator. For Rancimats and Karl Fischer instruments.

    1 piece(s)

  • Needle with Luer connector
    6.2816.030
    Needle with Luer connector

    Needle for filling in mercury into the Multi-Mode Electrode and for sample addition in Karl Fischer titration.


     


    2 piece(s)

  • Syringe 5 mL
    6.2816.090
    Syringe 5 mL

    5 mL syringe made of PP, with Luer connector.


    2 piece(s)

  • USB Memory Stick for 900 Touch Control 
    6.6064.010
    USB Memory Stick for 900 Touch Control 

    1 piece(s)

Ladda ner hela leveransomfattningen och extra tillbehör som PDF

  • USB thermal printer Neo's
    2.141.0100
    USB thermal printer Neo's

    Compact printer with USB interface for the Ti-Touch, the Titrino plus and Dosimat plus and the 91X Meter instruments.

    Paper width 60 mm (40 characters). Including 6.2151.120 USB cable.