877 Titrino plus

877 Titrino plus
Part Number: 2.877.0010

Compact titrator for

  • potentiometric endpoint titrations (SET)
  • monotonic titrations with automatic equivalence point finding (MET)

 

  • Documentos
  • Peças
  • Opções

Faça o download do escopo completo de entrega e acessórios opcionais

  • Numerical USB keypad
    6.2147.000
    Numerical USB keypad

    Numerical USB keypad for Titrino plus, Dosimat plus, 862 Compact Titrosampler, 869 Compact Sample Changer, 863 Compact Autosampler and 899 Coulometer. With two integrated USB connectors.

    1 piece(s)

  • Adapter USB MINI (OTG) - USB A
    6.2151.100
    Adapter USB MINI (OTG) - USB A
    For connecting USB instruments.

    1 piece(s)

  • Wrench
    6.2739.010
    Wrench
    For exchange units.

    1 piece(s)

Faça o download do escopo completo de entrega e acessórios opcionais

  • USB thermal printer Neo's
    2.141.0100
    USB thermal printer Neo's

    Compact printer with USB interface for the Ti-Touch, the Titrino plus and Dosimat plus and the 91X Meter instruments.

    Paper width 60 mm (40 characters). Including 6.2151.120 USB cable.

  • 801 Stirrer with stand
    2.801.0040
    801 Stirrer with stand

    Magnetic stirrer including base plate, support rod and electrode holder for supplementing the Titrino plus, Dosimat plus, Titrandos, Sample Processors, 805 Dosimat and 780/781 pH meters as well as the 856 and 867 measuring modules. With permanently attached cable for MSB (Metrohm Serial Bus).

  • 802 Stirrer (propeller stirrer) for 804 Ti Stand
    2.802.0040
    802 Stirrer (propeller stirrer) for 804 Ti Stand
    Rod stirrer with 6.1909.010 Propeller stirrer.
  • 804 Ti Stand with stand
    2.804.0040
    804 Ti Stand with stand
    Titration stand and controller for 802 Rod Stirrer. The 804 Ti Stand together with the optional 802 Rod Stirrer provides an alternative to the magnetic stirrer. Ti Stand with base plate, support rod and electrode holder.
  • 865 Dosimat plus
    2.865.0010
    865 Dosimat plus

    Universal dispensing unit for titration and dosing tasks in the laboratory. Including push-button cable for manual dispensing control and 6.3026.220 exchange unit (20 mL). A multitude of instruments can be connected at the USB interface of the Dosimat plus, even a number of them simultaneously when a USB hub is used (keyboard, mouse, USB compact printer or USB DIN A4 printer, USB Memory Stick for methods and data backup). The optional 6.2148.030 USB/RS-232 Adapter Box enables the connection of laboratory balances and operation with a computer.

    With its four dosing modes, the Dosimat plus offers a multitude of applications:

    DOS (Dosing) – Dosing at the press of a button

    This mode is particularly suitable for performing manual titrations with indicator. A result can be calculated and a result report can be printed automatically from the dosed volume.

    XDOS (Extended dosing) – Controlled dosing

    • Fixed volume dosing: The volume and the dosing rate are specified.
    • Time-controlled dosing: The volume and the time are specified.
    • Dosing according to dosing rate: The dosing rate and the time are specified.

    If continuous dosing without interruption is required, then the 865 Dosimat plus can be operated together with an 805 Dosimat in tandem mode.

    CNT D (Content dosing) – Preparation of standard and other solutions.

    The volume of the solvent to be dosed is determined automatically on the basis of the sample size of the starting substance (solid or stock solution) and the specified target concentration.

    LQT (Liquid transfer) – Pipetting and diluting of liquids.

  • 869 Compact Sample Changer
    2.869.0010
    869 Compact Sample Changer

    The 869 Compact Sample Changer offers the rapid and simple automation of Titrino plus applications in a very small space. For low numbers of multiple determinations or small sample series, this sample changer is just the right choice. Various titrations can be performed fully automatically and the electrodes can be cleaned and stored in a total of 12 positions.
    Thanks to the large and clearly organized live display, the current status of the sample series can be recognized directly and important samples can be given preferential analysis at any time.
    Various method templates can be used as the basis for creating and storing application-specific methods. Communication between Compact Sample Changer and Titrino plus takes place via remote signals without an additional control box or PC being required.
     

  • 876 Dosimat plus
    2.876.0010
    876 Dosimat plus

    Universal dispensing unit for manual titrations and dosings. Including push-button cable for manual dosing control and 20 mL exchange unit. A multitude of instruments can be connected at the USB interface of the Dosimat plus, even a number of them simultaneously when a USB hub is used (keyboard, mouse, USB compact printer or USB DIN A4 printer, USB Memory Stick for methods and data backup). The optional 6.2148.030 USB/RS-232 Adapter Box enables the connection of laboratory balances and operation with a computer. With its two dosing modes, the Dosimat plus offers the following applications:

    DOS (Dosing) – Dosing at the press of a button

    This mode is particularly suitable for performing manual titrations with indicator. A result can be calculated and a result report can be printed automatically from the dosed volume.

    XDOS (Extended dosing) – Controlled dosing

    • Fixed volume dosing: The volume and the dosing rate are specified.
    • Time-controlled dosing: The volume and the time are specified.
    • Dosing according to dosing rate: The dosing rate and the time are specified.
  • Optrode
    6.1115.000
    Optrode

    Optical sensor for photometric titrations offering 8 different wavelengths.
    Switching of the wavelength can be done via software (tiamo 2.5 or higher) or with a magnet.
    The glass shaft is completely solvent-resistant and easy to clean.
    This space-saving sensor is suitable, e.g.:

    • for non-aqueous titrations in accordance with USP or EP
    • for determination of carboxyl end groups
    • for TAN/TBN in accordance with ASTM D974
    • for sulfate determination
    • Fe, Al, Ca in cement
    • water hardness
    • Chondroitin sulfate in accordance with USP
  • Electrode cable / 1 m / F
    6.2104.020
    Electrode cable / 1 m / F
    For connecting electrodes with Metrohm plug-in head G to Metrohm instruments (socket F).
  • Electrode Cable 2 m / F
    6.2104.030
    Electrode Cable 2 m / F
    For connecting electrodes with Metrohm plug-in head G to Metrohm instruments (socket F).
  • Remote cable Compact Sample Changer/Compact Autosampler - Titrino plus/Pump Station
    6.2141.230
    Remote cable Compact Sample Changer/Compact Autosampler - Titrino plus/Pump Station
    Cable for the remote connection between Compact Sample Changer/Compact Autosampler and Titrino plus and/or Pump Station.
  • Remote cable Dosimat plus - Compact Sample Changer/Titrino plus
    6.2141.240
    Remote cable Dosimat plus - Compact Sample Changer/Titrino plus
    Cable for the remote connection between Dosimat plus and Compact Sample Changer and/or Titrino plus using 6.2141.260 Cable.
  • Remote cable Compact Sample Changer - Titrino
    6.2141.250
    Remote cable Compact Sample Changer - Titrino
    Cable for the remote connection between Compact Sample Changer and Titrinos with 25-pin remote socket.
  • Remote cable Compact Sample Changer - Dosimat plus and Titrino plus
    6.2141.260
    Remote cable Compact Sample Changer - Dosimat plus and Titrino plus
    Cable for remote connection between Compact Sample Changer and Dosimat plus and further devices (e.g. Titrino plus or Pump Station).
  • RS-232/USB Box
    6.2148.030
    RS-232/USB Box

    Extends the Titrino plus by two RS-232 interfaces, e.g., for the connection of balances, PC (tiBase software), LIMS. Requires 6.2151.030 cable.

  • Cable USB MINI (OTG) - USB B, 1.8 m
    6.2151.120
    Cable USB MINI (OTG) - USB B, 1.8 m
    For connecting USB instruments.
  • Protective cover for Titrino plus
    6.2723.310
    Protective cover for Titrino plus

    Protective cover for display and keypad for all instruments of the Titrino plus family.


    Suitable for: 848 Titrino plus, 862 Compact Titrosampler, 863 Compact Autosampler, 865 Dosimat plus, 869 Compact Sample Changer, 870 KF Titrino plus, 876 Dosimat plus, 877 Titrino plus, 899 Coulometer.


     


  • Exchange Unit 1 mL
    6.3026.110
    Exchange Unit 1 mL
    Exchange Unit with integrated data chip with 1 mL glass cylinder and light protection. PCTFE/PTFE flat stopcock, FEP tubing connection, antidiffusion buret tip and standard amber glass reagent bottle.
  • Exchange Unit 5 mL
    6.3026.150
    Exchange Unit 5 mL
    Exchange Unit with integrated data chip with 5 mL glass cylinder and light protection. PCTFE/PTFE flat stopcock, FEP tubing connection, anti-diffusion buret tip and standard amber glass reagent bottle.
  • Exchange Unit 10 mL
    6.3026.210
    Exchange Unit 10 mL
    Exchange unit with integrated data chip with 10 mL glass cylinder and light protection. PCTFE/PTFE flat stopcock, FEP tubing connection, anti-diffusion buret tip and standard amber glass reagent bottle.
  • Exchange Unit 20 mL
    6.3026.220
    Exchange Unit 20 mL
    Exchange unit with integrated data chip with 20 mL glass cylinder and light protection. PCTFE/PTFE flat stopcock, FEP tubing connection, anti-diffusion buret tip and standard amber glass reagent bottle.
  • Exchange unit 50 mL
    6.3026.250
    Exchange unit 50 mL

    Exchange unit with integrated data chip with 50 mL glass cylinder and light protection. PCTFE/PTFE flat stopcock, FEP tubing connection, antidiffusion tip and standard amber glass reagent bottle.


  • tiBase 1.1 full (1 license)
    6.6063.112
    tiBase 1.1 full (1 license)

    PC program for managing titration data.


    The following instruments are supported:

    • 899 Coulometer
    • 848 Titrino plus
    • 862 Compact Titrosampler
    • 870 Titrino plus
    • 877 Titrino plus
    • 840 Touch Control (Titrando)
    • 900 Touch Control (Titrando)
    • 912 Conductometer
    • 913 pH Meter
    • 914 pH/Conductometer
    • 915 KF Ti-Touch
    • 916 Ti-Touch
    • 917 Coulometer